• 제목/요약/키워드: environment condition

Search Result 6,759, Processing Time 0.035 seconds

Development of Geopolymer Mortar Based on Fly Ash (플라이애시 기반 지오폴리머 모르타르 개발)

  • Koh, Kyung-Taek;Ryu, Gum-Sung;Lee, Jang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.119-126
    • /
    • 2012
  • Portland cement production-1.5billion tonnes yearly worldwide-contributes substantially to global atmospheric pollution(7% of total of $CO_2$ emissions). Attempts to increase the utilization of fly ash, by-products from thermal power plant to partially replace the cement in concrete are gathering momentum. But most of fly ash is currently dumped in landfills, thus creating a threat to the environment. Many researches on alkali-activated concrete that does not need the presence of cement as a binder have been carried out recently. Instead, the sources of material such as fly ash, that are rich in Silicon(Si) and Aluminium(Al), are activated by alkaline liquids to produce the binder. Hence concrete with no cement is effect reduction of $CO_2$ gas. In this study, we investigated the influence of the compressive strength of mortar on alkaline activator and curing condition in oder to develop cementless fly ash based alkali-activated concrete. In view of the results, we found out that it was possible for us to make alkali-activated mortar with 70MPa at the age of 28days by using alkaline activator manufactured as 1:1 the mass ratio of 9M NaOH and sodium silicate and applying the atmospheric curing after high temperature at $60^{\circ}C$ for 48hours.

  • PDF

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.

A Study on the Prediction of Residual Probability of Fine Dust in Complex Urban Area (복잡한 도심에서의 유입된 미세먼지 잔류 가능성 예보 연구)

  • Park, Sung Ju;Seo, You Jin;Kim, Dong Wook;Choi, Hyun Jeong
    • Journal of the Korean earth science society
    • /
    • v.41 no.2
    • /
    • pp.111-128
    • /
    • 2020
  • This study presents a possibility of intensification of fine dust mass concentration due to the complex urban structure using data mining technique and clustering analysis. The data mining technique showed no significant correlation between fine dust concentration and regional-use public urban data over Seoul. However, clustering analysis based on nationwide-use public data showed that building heights (floors) have a strong correlation particularly with PM10. The modeling analyses using the single canopy model and the micro-atmospheric modeling program (ENVI-Met. 4) conducted that the controlled atmospheric convection in urban area leaded to the congested flow pattern depending on the building along the distribution and height. The complex structure of urban building controls convective activity resulted in stagnation condition and fine dust increase near the surface. Consequently, the residual effect through the changes in the thermal environment caused by the shape and structure of the urban buildings must be considered in the fine dust distribution. It is notable that the atmospheric congestion may be misidentified as an important implications for providing information about the residual probability of fine dust mass concentration in the complex urban area.

A Empirical Study on Preference Property for the Private Brand(PB) of Large Discount Stores in Gyeonggi-Do (경기지역의 대형할인점 유통업체브랜드(PB) 선호특성에 대한 실증연구)

  • Kim, Jeong-in;Lee, Jae-hak;Han, Kyu-baek
    • Journal of Distribution Science
    • /
    • v.5 no.2
    • /
    • pp.101-117
    • /
    • 2007
  • Recently, in the process of distribution industry's growth, distribution environment is changing rapidly by appearance of new business condition and strategy of multiple store. According to the intensification of competition, recently large discount stores are developing private brand(PB) products for the purpose of product differentiation and profitability. But after the economic crisis in 1997, young housewives and salaried man's that have rational and practical buying pattern become the core consumer's in the large discount stores. Hence low price strategy is not new things for the consumer's anymore. In addition to, acquiring new consumer, many discount stores are establishing new stores at the rural area. But they undergo hardships of establishing new stores at the rural area because of disparity consumer's behavior, income level and consumption's pattern among regions. So, when they try to establish new stores, they need to know consumer's behavior at the region. Therefore the purpose of this study is to analyze preference property for the private brand(PB) of large discount stores in Gyeonggi-Do.

  • PDF

Method of Walking Surface Identification Technique for Automatic Change of Walking Mode of Intelligent Bionic Leg (지능형 의족의 보행모드 자동변경을 위한 보행노면 판별 기법)

  • Yoo, Seong-Bong;Lim, Young-Kwang;Eom, Su-Hong;Lee, Eung-Hyuk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.81-89
    • /
    • 2017
  • In this paper, we propose a gait pattern recognition method for intelligent prosthesis that enables walking in various environments of femoral amputees. The proposed gait mode changing method is a single sensor based algorithm which can discriminate gait surface and gait phase using only strain gauges sensor, and it is designed to simplify the algorithm based on multiple sensors of existing intelligent prosthesis and to reduce cost of prosthesis system. For the recognition algorithm, we analyzed characteristics of the ground reaction force generated during gait of normal person and defined gait step segmentation and gait detection condition, A gait analyzer was constructed for the gait experiment in the environment similar to the femoral amputee. The validity of the paper was verified through the defined detection conditions and fabricated instruments. The accuracy of the algorithm based on the single sensor was 95%. Based on the proposed single sensor-based algorithm, it is considered that the intelligent prosthesis system can be made inexpensive, and the user can directly grasp the state of the walking surface and shift the walking mode. It is confirmed that it is possible to change the automatic walking mode to switch the walking mode that is suitable for the walking mode.

Effect of Types and Replacement Ratio of Alkali Activator on Compressive Strength of Ground Granulated Blast Furnace Slag Mortar (알칼리 자극제의 종류 및 치환율이 고로슬래그 미분말 모르타르의 압축강도에 미치는 영향)

  • Kim, Rae-Hwan;Kim, Gyu-Yong;Kim, Jong-Hee;Lee, Bo-Kyeong;Cho, Bong-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.4
    • /
    • pp.360-366
    • /
    • 2014
  • In this study, effect of types and replacement ratio of alkali activator on compressive strength of ground granulated blast furnace slag mortar has been reviewed. Types of alkali activator are NaOH, $Ca(OH)_2$, $Na_2SO_4$, and KOH. Replacement ratio of alkali activator is 7.5, 10, 12.5, and 15%, respectively. As results, under high temperature curing condition, 1 day compressive strength development with NaOH and KOH was higher than that of $Ca(OH)_2$ and $Na_2SO_4$. Regardless of types of alkali activator, compressive strength increased with increasing pH. This can be explained by the fact that impermeable film on the surface of slag which is generated when slag contacts water has been destroyed by alkali activator, and this promotes hydration reaction. Also, 1 day age compressive strength of specimen with high temperature curing was higher than that of specimen with standard curing. 28 days age compressive strength of specimen with high temperature curing was less than or equal to that of specimen with standard curing.

Active-Sensing Based Damage Monitoring of Airplane Wings Under Low-Temperature and Continuous Loading Condition (능동센서 배열을 이용한 저온 반복하중 환경 항공기 날개 구조물의 손상 탐지)

  • Jeon, Jun Young;Jung, Hwee kwon;Park, Gyuhae;Ha, Jaeseok;Park, Chan-Yik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.345-352
    • /
    • 2016
  • As aircrafts are being operated at high altitude, wing structures experience various fatigue loadings under cryogenic environments. As a result, fatigue damage such as a crack could be develop that could eventually lead to a catastrophic failure. For this reason, fatigue damage monitoring is an important process to ensure efficient maintenance and safety of structures. To implement damage detection in real-world flight environments, a special cooling chamber was built. Inside the chamber, the temperature was maintained at the cryogenic temperature, and harmonic fatigue loading was given to a wing structure. In this study, piezoelectric active-sensing based guided waves were used to detect the fatigue damage. In particular, a beamforming technique was applied to efficiently measure the scattering wave caused by the fatigue damage. The system was used for detection, growth monitoring, and localization of a fatigue crack. In addition, a sensor diagnostic process was also applied to ensure the proper operation of piezoelectric sensors. Several experiments were implemented and the results of the experiments demonstrated that this process could efficiently detect damage in such an extreme environment.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

Optimal Fermentation Conditions of Hyaluronidase Inhibition Activity on Asparagus cochinchinensis Merrill by Weissella cibaria

  • Kim, Minji;Kim, Won-Baek;Koo, Kyoung Yoon;Kim, Bo Ram;Kim, Doohyun;Lee, Seoyoun;Son, Hong Joo;Hwang, Dae Youn;Kim, Dong Seob;Lee, Chung Yeoul;Lee, Heeseob
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.4
    • /
    • pp.701-708
    • /
    • 2017
  • This study was conducted to evaluate the hyaluronidase (HAase) inhibition activity of Asparagus cochinchinesis (AC) extracts following fermentation by Weissella cibaria through response surface methodology. To optimize the HAase inhibition activity, a central composite design was introduced based on four variables: the concentration of AC extract ($X_1$: 1-5%), amount of starter culture ($X_2$: 1-5%), pH ($X_3$: 4-8), and fermentation time ($X_4$: 0-10 days). The experimental data were fitted to quadratic regression equations, the accuracy of the equations was analyzed by ANOVA, and the regression coefficients for the surface quadratic model of HAase inhibition activity in the fermented AC extract were estimated by the F test and the corresponding p values. The HAase inhibition activity indicated that fermentation time was most significant among the parameters within the conditions tested. To validate the model, two different conditions among those generated by the Design Expert program were selected. Under both conditions, predicted and experimental data agreed well. Moreover, the content of protodioscin (a well-known compound related to anti-inflammation activity) was elevated after fermentation of the AC extract at the optimized fermentation condition.

An study on guide to oil spill response in snow and ice condition in seas (유빙유입에 따른 해양오염사고 대응방안 마련 연구)

  • Lim, Ji Young;Lee, Seung Hwan;Hyun, Chung Guk;Park, Chan Hyun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2018.06a
    • /
    • pp.16-16
    • /
    • 2018
  • 2017년 겨울, 기록적인 한파로 인해 바다가 얼면서 인천 앞바다로 유빙이 유입되었다. 2013년 해상에서 유빙이 발견된 이후 약 5년만에 다시 유빙이 등장한 것이다. 중부청 소속 항공단 순찰결과에 따르면, 2018년 1월 12일 인천대교 인근 해상에서 최초로 발견된 이후 강화 연안, 영종도 북단 등 해상에서 광범위하고 불규칙한 형태로 유빙이 분포되어 있는 것으로 나타났다. 유빙의 문제점은 해상에서 선박의 안전운항을 저해하고 경비함정의 안전에 지장을 초래하며 기름 유출 시, 유출유의 거동 특성이 달라져 일반적인 방제방법의 적용이 곤란한 점이다. 이에 따라 해상에서의 해양오염사고 대응방안 마련을 위해 저온 및 유빙 유입 해상에서 유출유의 거동 특성을 알아보았다. 구분인자를 극한의 추위(Extreme Cold), 유빙(Pack Ice), 정착빙(Fast Ice) 3가지로 분류하여 기름의 성상변화 및 시사점을 살펴보고, 유출된 기름의 효율적 방제를 크게 3가지로 분류(기계적 봉쇄 및 회수, 화학적 분산제의 사용, 현장소각)하였다. 일반적인 방제장비를 저온 및 얼음분포 해상에서 사용 시 슬러시화 된 얼음으로 인해 유출유 회수가 어렵고, 동결온도에서 장비가 오작동할 우려가 있다. 이미 북유럽 국가에서는 극한의 추위와 얼음분포 해상에 특화된 방제장비를 도입하여 해양오염대비 대응을 하고 있다. 2003년 3월 발틱해에서 불법적으로 유출한 선저폐수를 특화 장비는 brush bucket 유회수기 이용 방제조치한 사례가 있으며, 2006년 5월 같은 장소에서 선박 침몰로 인한 기름 유출이 발생했을때도 brush bucket 유회수기 이용 방제조치를 하였다. 국내에도 이상 기후로 인해 기록적인 한파가 지속되면서 북극에서나 볼 법한 유빙들이 발견되고, 해양오염사고는 언제 어디서나 발생할 수 있으므로, 해양오염방제의 임무를 맡고 있는 국가기관으로써 특수한 환경까지도 고려하여 대응방안을 마련할 필요가 있다. 해양오염이 재난으로 인식되고 있는 상황에서, 그리고 지구온난화로 인한 이상기후변화가 지속되는 상황에서 겨울철 유빙 유입은 점점 더 많아질 수 있다. 본 연구에서는 자료나 방제경험이 부족하므로 일찌감치 북극항로 개발로 앞선 방제기술과 경험을 가지고 있는 북극이사회를 벤치마킹하여 관할 해역 특성에 맞는 대응방안을 고찰해 본다.

  • PDF