• Title/Summary/Keyword: environment condition

Search Result 6,759, Processing Time 0.042 seconds

The Study on Ozone Treatment of Wasting Activated Sludge for VFA Production and Reuse as Carbon Source for Phosphorus Release (잉여슬러지의 오존분해에 따른 VFA의 생성 및 인 방출을 위한 탄소원으로의 재이용 가능성에 관한 연구)

  • Ko, Eun-Taek;Cho, Jin-Woo;Park, Eun-Young;Ahn, Kyu-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1052-1057
    • /
    • 2005
  • Recently, the ozone treatment of wasting activated sludge has become one of the effective and feasible process for the sludge reduction. The objective of this study is to investigate the availability of ozonized wasting sludge on external carbon sources 13r phosphorus release. Experiment results showed that the ozone treatment of activated sludge could produce a large amount of VFA such as acetic acid and isobutyric acid. For example, 50.24 mg/L acetic acid was produced with the ozone dose of 0.05 g $O_3/g$ SS, and 123.56 mg/L acetic acid with 0.5 g $O_3/g$ SS. The higher ozone dose was applied, the more VFA was produced from sludge reduction into a limited point. Finally, using ozonated sludge as only carbon source, the batch experiment, to measure phosphorus release rate in anaerobic condition were performed. The specific phosphorus release rates were investigated as 0.94, 1.37, 1.48, 1.68 mg P/g VSS/hr with ozone dose of 0.05, 0.1, 0.2, 0.5 g $O_3/g$ SS, respectively. Considering the degree of mineralization, VFA production, phosphorus release rate, and economical aspect, the optimal ozone dose for sludge reduction and using carbon sources ranged from 0.05 to 0.1 g $O_3/g$ SS.

Analysis of the Location Environment of the Sub-alpine Coniferous Forest in National Parks Using GIS - Focusing on Abies koreana - (GIS를 활용한 국립공원 아고산대 침엽수림의 입지환경 분석 - 구상나무를 대상으로 -)

  • Kim, Tae-Geun;Oh, Jang-Geun
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.236-243
    • /
    • 2016
  • It was a case study to use as a basic data for efficient the preservation and management of subalpine coniferous forest in national parks. It is based on inhabitation condition of 210 individuals of Abies koreana Wilson that was found through local investigation in the sub-alpine zone of Jirisan National Park and Songnisan National Park. It analyzed the effect of the geographical location and topographical features, which are the basics of location environment, on the growth of A. koreana. The variables related to the growth of A. koreana are tree height and diameter at breast height. Topographical features include geographical longitude, altitude above sea level, slope of the mountains, aspect that describes the direction in which a slope faces and topographical wetness index. Topographical features were extracted through GIS spatial analysis. It used canonical correlation analysis to estimate whether the two variables groups have related to each other and how much they are related, if any, and estimated the effect of the geographical and topographical features on the growth structure of A. koreana using multiple regression analysis. The tree height and diameter at breast height that represent the growth structure of A. koreana show greater relation to geographical latitude distribution than topographical feature and the geographical and topographical factors show greater relation to diameter at breast height than tree height. The growth structure's variable and geographical and topographical variable of A. koreana have meaningful relation and the result shows that geographical and topographical variables explain 18.1% of the growth structure. The variables that affect the diameter at breast height of A. koreana are geographical latitude, topographical wetness index, aspect and altitude, which are put in order of statistical significance. The higher the latitude is, the smaller the diameter at breast height. Depending on the topographical feature, it becomes bigger. The variable that affects the tree height is topographical wetness index, which was the only meaningful variable. Overall, the tree height and diameter at breast height that are related to the growth structure of A. koreana are affected by geographical and topographical feature. It showed that the geographical feature affected it the most. Especially the effect of water among the topographical features is expected to be bigger than the other topographical factors. Based on the result, it is expected that geographical and topographical feature is an important factor for the growth structure of A. koreana. Even though it considered only the geographical and topographical features and used spatial analysis data produced by GIS, the research results will be useful for investigating and researching the growth environment of coniferous forest inhabiting in sub-alpine zone of national parks and are expected to be used as basic data for establishing measures to efficiently manage and preserve evergreen needleaf tree such as A. koreana.

Analysis of the Effect of Heat Island on the Administrative District Unit in Seoul Using LANDSAT Image (LANDSAT영상을 이용한 서울시 행정구역 단위의 열섬효과 분석)

  • Lee, Kyung Il;Ryu, Jieun;Jeon, Seong Woo;Jung, Hui Cheul;Kang, Jin Young
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.821-834
    • /
    • 2017
  • The increase in the rate of industrialization due to urbanization has caused the Urban Heat Island phenomenon where the temperature of the city is higher than the surrounding area, and its intensity is increasing with climate change. Among the cities where heat island phenomenon occurs, Seoul city has different degree of urbanization, green area ratio, energy consumption, and population density in each administrative district, and as a result, the strength of heat island is also different. So It is necessary to analyze the difference of Urban Heat Island Intensity by administrative district and the cause. In this study, the UHI intensity of the administrative gu and the administrative dong were extracted from the Seoul metropolitan area and the differences among the administrative districts were examined. and linear regression analysis were conducted with The variables included in the three categories(weather condition, anthropogenic heat generation, and land use characteristics) to investigate the cause of the difference in heat UHI intensity in each administrative district. As a result of analysis, UHI Intensity was found to be different according to the characteristics of administrative gu, administrative dong, and surrounding environment. The difference in administrative dong was larger than gu unit, and the UHI Intensity of gu and the UHI Intensity distribution of dongs belonging to the gu were also different. Linear regression analysis showed that there was a difference in heat island development intensity according to the average wind speed, development degree, Soil Adjusted Vegetation Index (SAVI), Normalized Difference Built-up Index (NDBI) value. Among them, the SAVI and NDBI showed a difference in value up to the dong unit and The creation of a wind route environment for the mitigation of the heat island phenomenon is necessary for the administrative dong unit level. Therefore, it is considered that projects for mitigating heat island phenomenon such as land cover improvement plan, wind route improvement plan, and green wall surface plan for development area need to consider administrative dongs belonging to the gu rather than just considering the difference of administrative gu units. The results of this study are expected to provide the directions for urban thermal environment design and policy development in the future by deriving the necessity of analysis unit and the factors to be considered for the administrative city unit to mitigate the urban heat island phenomenon.

제주도 지하수자원의 최적 개발가능량 선정에 관한 수리지질학적 연구

  • 한정상;김창길;김남종;한규상
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1994.07a
    • /
    • pp.184-215
    • /
    • 1994
  • The Hydrogeologic data of 455 water wells comprising geologic and aquifer test were analyzed to determine hydrogeoloic characteristics of Cheju island. The groundwater of Cheju island is occurred in unconsolidated pyroclastic deposits interbedded in highly jointed basaltic and andesic rocks as high level, basal and parabasal types order unconfined condition. The average transmissivity and specific yield of the aquifer are at about 29,300m$^2$/day and 0.12 respectively. The total storage of groundwater is estimated about 44 billion cubic meters(m$^3$). Average annual precipitation is about 3390 million m$^3$ among which average recharge amount is estimated 1494 million m$^3$ equivalent 44.1% of annual precipitation with 638 million m$^3$ of runoff and 1256 million m$^3$ of evapotranspiration. Based on groundwater budget analysis, the sustainable yield is about 620 million m$^3$(41% of annual recharge)and rest of it is discharging into the sea. The geologic logs of recently drilled thermal water wens indicate that very low-permeable marine sediments(Sehwa-ri formation) composed of loosely cemented sandy sat derived from mainly volcanic ashes, at the 1st stage volcanic activity of the area was situated at the 120$\pm$68m below sea level. And also the other low-permeable sedimentary rock called Segipo-formation which is deemed younger than former marine sediment is occured at the area covering north-west and western part of Cheju at the $\pm$70m below sea level. If these impermeable beds are distributed as a basal formation of fresh water zone of Cheju, most of groundwater in Cheju will be para-basal type. These formations will be one of the most important hydrogeologic boundary and groundwater occurences in the area.

  • PDF

Effect of Slurry Composting Bio-filtration (SCB) by Subsurface Drip Fertigation on Cucumber (Cucumis sativus L.) Yield and Soil Nitrogen Distribution in Greenhouse

  • Lim, Tae-Jun;Park, Jin-Myeon;Noh, Jae-Seung;Lee, Seong-Eun;Kim, Ki-In
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.4
    • /
    • pp.253-259
    • /
    • 2013
  • The use of subsurface drip fertigation using slurry composting bio-filtration (SCB) as nitrogen (N) fertilizer source can be beneficial to improve fertilizer management decision. The objective of this study was to evaluate effects of SCB liquid fertilizer by subsurface drip fertigation on cucumber (Cucumis sativus L.) yield and soil nitrogen (N) distribution under greenhouse condition. Cucumber in greenhouse was transplanted on April $4^{th}$ and Aug $31^{st}$ in 2012. N sources were SCB and urea. Four N treatments with 3 replications consisted of control (No N fertilizer), SCB 0.5N + Urea 0.5N (50:50 split application), SCB 1.0N, Urea 1.0N. 100% of N recommendation rate from soil testing was denoted as 1.0N. The subsurface drip line and a tensiometer were installed at 30 cm soil depth. An irrigation was automatically started when the tensiometer reading was -15 kPa. The growth of cucumber at 85 days after transplanting was 5% higher in all N treatment than control. Semi-forcing culture produced more fruit yield than retarding culture. Fruit yields were 62.2, 76.3, 76.4, and 75.1 Mg $ha^{-1}$ for control, SCB 1.0N, Urea 1.0N, and SCB 0.5N + Urea 0.5N, respectively. Although fruit yields were similar under SCB 1.0N, Urea 1.0N, and SCB 0.5N + Urea 0.5N, 176 kg K $ha^{-1}$ can be over applied if cucumber is grown twice a year under SCB 1.0N that may result in K accumulation in soil. N uptake was 172, 209, 213, 207 kg $ha^{-1}$ for control, SCB 1.0N, Urea 1.0N, and SCB 0.5N + Urea 0.5N, respectively. N use efficiency was the highest (37%) at SCB 0.5N + Urea 0.5N under semi-forcing culture. Nitrate-N concentration in soil for all N treatments except control in semi-forcing culture was the highest between 15 and 30 cm soil depth at the 85 days after transplanting and between 0 and 15 cm soil depth after cucumber harvest. These results suggested that SCB 0.5N + Urea 0.5N can be used as an alternative N management for cucumber production in greenhouse if K accumulation is concerned.

Effect of Highly Concentrated Turbid Water on the Water Quality and Periphytic Diatom Community in Artificial Channel (인공수로에서 고농도 탁수가 수질 및 부착 규조류 군집에 미치는 영향)

  • Yoon, Sung-Ae;You, Kyung-A;Park, Ji-Hyoung;Kim, Baik-Ho;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.1
    • /
    • pp.75-84
    • /
    • 2011
  • We examined the effect of the turbid water on the periphytic diatom community in an artificial stream system. The artificial stream was constructed with transparent acryl and composed of four channels. Each channel ($20\;cm{\times}200\;cm{\times}40\;cm$) was supplied continuously with eutrophic lake water. In order to the freely colonize and grow diatoms, artificial substrate was installed with commercial slide glass soaked in 1% agar. Prior to introducing turbid water, the artificial stream was operated with lake water for 6 days to permit the propagation of diatom community on the substrates. The turbid water prepared with sediment sieved with ${\varphi}$ $64\;{\mu}m$ at $2\;g\;L^{-1}$ (final concentration, 300 NTU) was provided daily for 50 minute duration. The experiment was conducted for 7 days with manipulated experimental condition of light ($50{\sim}80\;{\mu}mol\;m^{-2}s^{-1}$, light:dark=24:0), temperature ($10{\pm}1^{\circ}C$), and flow rate ($0.31\;cm\;s^{-1}$). Sampling and analysis were conducted daily for water quality and diatom. Turbidity of the water varied 162.2~173.2 NTU during the experiment. After introduction of turbid water, DO, pH and TN were decreased, while SS and TP increased significantly. A total of 14 genera and 47 species of diatoms was observed on the artificial substrates during the experimental period. Of these, Navicula appeared to be a most dominant genus with 10 species, followed by Cymbella (6 species), Fragilaria (6 species) and Gomphonema (5 species). Achnanthes minutissima was the most dominant species (>70% of total frequency) in both control and treatment experiments. Increase in diatom abundance lasted for three days since turbid water introduction, after that they gradually decreased by the termination of the experiment. These results suggest that frequent supply of highly-concentrated turbid water significantly decreases the periphytic diatom community, and retard the recovery of the stable food-web within the stream.

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

The Variation of Benthic Macroinvertebrates Caused by Erosion Control Works in a Torrential Stream - Focused on Variation of Benthic Macroinvertebrates Analyzed immediately after Construction Works - (황폐계류의 사방공작물 시공에 따른 저서성 대형무척추동물상의 변화 - 시공 직후의 변화를 중심으로 -)

  • Lee, Do-Hyung;Lee, Ki-Hwan;Lee, Heon-Ho;Ma, Ho-Seop;Bae, Kwan-Ho;Kim, Jong-Hyon
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.4
    • /
    • pp.353-364
    • /
    • 2009
  • This study was conducted to evaluate the effect of erosion control works on the stream ecosystem in a mountain torrential stream. The species composition of benthic macroinvertebrates and biological water quality were investigated before and after construction of erosion control works at 5 sites. The total number of benthic macroinvertebrates before construction was 3,086 individuals including 4 phyla, 6 classes, 11 orders, 22 families, and 25 species, but after construction it has decreased to 1,208 individuals including 4 phyla, 6 classes, 10 orders, 17 families, and 19 species. Especially, the diversity, richness, and evenness indices, which were calculated based on existing number of biological species, have decreased or not produced at the erosion control sites, where biological species were not found or the minimum number of species were found. The results of community analysis of benthic macroinvertebrates and ESB(Ecological Score of Benthic macroinvertebrate community) indicated that the environmental qualities of the stream based on saprobity, environmental condition, and water quality decreased after the construction at all sites: before construction, the top of the stream was satisfactory and some satisfactory, the middle was some defectiveness, and the lower was defectiveness and very defectiveness; after construction, all parts of the stream except some parts of the top were very defectiveness. Moreover, the water quality of torrential stream was rated between I to III before construction, but after construction, it declined to $IV{\sim}V$ except control. The habitat damage of benthic macro invertebrates occurred at all investigation sites after the construction of erosion control works led to reduction of the number of biological species and water quality deterioration. The results reported in this study were collected directly after the construction of erosion control works. Therefore, additional studies are needed to further explore the effect of disaster-prevention of erosion control works and the recovery process of stream ecosystem through long term monitoring.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Available Phosphours Phosphorus and Electrical Conductivity of the Saturated Extracts of Soils from the Plastic Film Houses (포화침출액법에 의한 시설하우스 토양의 유효인산과 전기전도도)

  • Jung, Yeong-Sang;Cho, Su-Hyun;Yang, Jae E.;Kim, Jeong-Je;Um, Hyung-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • Management of phosphorus availability in the plastic film house soils in Korea merits attention because salts have been accumulated for last decades due to the heavy application of fertilizers and intensive cropping practices. In an attempt to characterize the P availability, available phosphorus contents and electrical conductivity of the saturated extracts ($EC_e$) were measured for soils collected from the 169 plastic film houses in Kangwon-do. Soil phosphorus contents were analyzed by methods of Lancaster, Bray No. 1, Olsen, Truog, water extractable and saturation extracts. Phosphorus concentrations in the saturated extracts of the plastic film house soils ranged from 0.02 to $34mg\;L^{-1}$, with the average of $8mg\;L^{-1}$. The available $P_2O_5$ of the soils ranged from 136 to $3,689mg\;Kg^{-1}$, with the average of $1,261mg\;Kg^{-1}$. The water soluble $P_2O_5$ ranged from 2 to $118mg\;L^{-1}$, with the average of $39mg\;L^{-1}$. A significant correlation existed between saturation extract P (Y) and available $P_2O_5$ (X) [Y = -5.075 + 0.018X, $r=0.662^{***}$] indicating $1.0mg\;P\;L^{-1}$ of in the saturated extract was equivalent to $337mg\;Kg^{-1}$ of the available $P_2O_5$ by Lancaster method. Electrical conductivity of the saturated pastes ($EC_e$) was highly significantly correlated with EC (1:5), yielding the slope of 12.2 for the coarse textured plastic film house soils. Results of higher concentrations of available P in soil solution and dilution factor of 12.2 for $EC_e$ demonstrate that a special care must be taken in terms of fertilizer management and data interpretation for soils under this specific condition.

  • PDF