• 제목/요약/키워드: envelope of motion

검색결과 46건 처리시간 0.021초

캠 합서에 관한 수치해석적 방법 (A Numerical Method for Cam Synthesis)

  • 심수섭;김창부
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.445-450
    • /
    • 2000
  • In this paper, a numerical method is proposed for cam synthesis. kinematics of closed loop system with cam and follower is presented using relative coordinates. The system is transformed into an open loop system by cutting fictitiously higher-pair contact of cam and follower and envelope constraint equations are derived. Follower constraint equations are derived from the motion of the follower ends. The joint variables and follower profile parameters are calculated from the envelope constraint equations and follower constraint equations by using the Newton - Raphson iterative method. Algorithms for cam synthesis are presented and simulations are done to verify the effectiveness of the proposed method.

  • PDF

경항공모함 이·착함 성능평가 및 안전임무 수행범주 일관 해석 연구 (A Study on Short-Take-Off and Vertical Landing (STOVL) Performance Evaluation of a Light Aircraft Carrier and a Consistent Analysis of Safe Operating Envelope (SOE))

  • 홍사영;박동민;정재환;서민국;조석규
    • 대한조선학회논문집
    • /
    • 제61권2호
    • /
    • pp.125-134
    • /
    • 2024
  • The Safe Operating Envelope (SOE) combined with Short-Take-Off and Vertical Landing (STOVL) performance is an essential consideration of a light aircraft carrier for design of hull shape with excellent seakeeping performance in terms of naval air operations as well as traditional naval ship missions such as Transit and Patrol (TAP), and Replenishment at Sea (RAS) and so on. A variety of procedures are systematically combined to determine SOE considering rather complicated missions associated with operation of aircraft onboard. The evaluation of take-off and landing safety missions onboard should consider wind effect on deck and severer seakeeping indices and standards compared with conventional naval ships. In order to support take-off and landing missions, various support activities of the crews are required. So, additional evaluation is needed for indicators such as MSI(Motion sickness Index) and MII(Motion Induced Interruptions), which are quantitative indicators of work ability that appear as a result of motion response. In this study, a standard procedure is developed including the seaworthiness performance indicators, standards, and evaluation procedures that should be considered during design of STOVL aircraft carrier. Analysis results are discussed in terns of air-wake on deck as well as seakeeping indices associated with design parameter changes in view of conceptual design of a light aircraft carrier.

고정밀 서피스 서보 방법론 (High-Precision Surface Servo Methodology)

  • 정광석;박준규;심기본
    • 융복합기술연구소 논문집
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2013
  • High-precision surface actuator, in which in-plane motion is realized by not two-dimensional actuator superposing linear actuators but integrated planar actuator, has been developed to cope with the severe target performance like precise motion with large envelope. It is very difficult to accomplish the performance with the traditional actuating principle. So, various methods have been tried to break through the problem. This paper discusses some meaningful trials performed in the Nano Measurement and Precision Motion Control Lab. of Korea National University of Transportation.

  • PDF

Dynamic Electromyography Analysis of Shoulder Muscles for One-handed Manual Material Handling

  • Mo, Seung-Min;Jung, Myung-Chul
    • 대한인간공학회지
    • /
    • 제34권4호
    • /
    • pp.313-326
    • /
    • 2015
  • Objective: The objective of this research is to quantitatively analyze muscle activities of arm and shoulder, according to direction in various types of one-handed manual material handling, based on surface electromyography. Background: Workers in industrial sites frequently carry out one-handed manual material handling using arm and shoulder muscles. Therefore, chronic load and accumulated fatigue occur to arm and shoulder muscles, which becomes a main cause of upper arm and shoulder musculoskeletal disorders. The shoulder muscles have widely range of motion, and complex interactions take place among various muscles including rotator cuff muscles. In this regard, research on interactions among should muscles, according to such various dynamic motions, is required. Method: Ten male subjects in their 20s participated in this research. This research considered upward, downward, leftward, rightward, forward and backward directions and fourteen muscles around arm and shoulder (biceps brachii and trapezius, etc.) as independent variables. The mean muscle activity was set as the dependent variable. This research extracted $4^{th}{\sim}7^{th}$ repetition signals according to ten times of repetitive muscle contraction, and analyzed the muscle activity concerned using the envelope detection technique. Results: The mean muscle activity of upward direction was analyzed highly statistically significant. The reason is that the effect of gravity works to arm and shoulder muscles. Also, it is conjectured that deformation of coracoacromial ligament was caused, and its contact pressure increased, due mainly to the shoulder flexion, and therefore load was analyzed high. Muscle activity was analyzed significantly low, according to concentric ballistic motion used in the concentric contraction phase by storing elastic energy in the eccentric contraction phase with a motion to bring the weight to the front of subject's body as to downward, leftward and backward directions. Because, elbow joint's flexion-extension motions mainly occurred, biceps brachii was analyzed high muscle activity as the prime mover. Conclusion: The information on the quantitative load of muscles can be applied to ergonomic work design for one-handed manual material handling to minimize muscle load. Application: This research has effectively identified muscle activity according to dynamic contraction by applying an envelope detection technique. The results can be used for ergonomic work design to minimize muscle load during the one-handed manual material handling, according to each direction. The research results are expected to be used for musculoskeletal disorder prevention and physiotherapy in the rehabilitation medical field, based on the muscle load of arm and shoulder in various directions.

Simulation method of ground motion matching for multiple targets and effects of fitting parameter variation on the distribution of PGD

  • Wang, Shaoqing;Yu, Ruifang;Li, Xiaojun;Lv, Hongshan
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.563-573
    • /
    • 2019
  • When generating spectrum-compatible artificial ground motion in engineering practices, the effect of the variation in fitting parameters on the distribution of the peak ground displacement (PGD) has not yet drawn enough attention. In this study, a method for simulating ground motion matching for multiple targets is developed. In this method, a frequency-dependent amplitude envelope function with statistical parameters is introduced to simulate the nonstationarity of the frequency in earthquake ground motion. Then, several groups of time-history acceleration with different temporal and spectral nonstationarities were generated to analyze the effect of nonstationary parameter variations on the distribution of PGD. The following conclusions are drawn from the results: (1) In the simulation of spectrum-compatible artificial ground motion, if the acceleration time-history is generated with random initial phases, the corresponding PGD distribution is quite discrete and an uncertain number of PGD values lower than the limit value are observed. Nevertheless, the mean values of PGD always meet the requirement in every group. (2) If the nonstationary frequencies of the ground motion are taken into account when fitting the target spectrum, the corresponding PGD values will increase. A correlation analysis shows that the change in the mean and the dispersion values, from before the frequencies are controlled to after, correlates with the modal parameters of the predominant frequencies. (3) Extending the maximum period of the target spectrum will increase the corresponding PGD value and, simultaneously, decrease the PGD dispersion. Finally, in order to control the PGD effectively, the ground motion simulation method suggested in this study was revised to target a specified PGD. This novel method can generate ground motion that satisfies not only the required precision of the target spectrum, peak ground acceleration (PGA), and nonstationarity characteristics of the ground motion but also meets the required limit of the PGD, improving engineering practices.

Gradient Optimized Gradient-Echo Gradient Moment Nulling Sequences for Flow Compensation of Brain Images

  • Jahng, Geon-Ho;Stephen Pickup
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.20-26
    • /
    • 2000
  • Gradient moment nulling techniques require the introduction of an additional gradient on each axis for each order of motion correction to be applied. The additional gradients introduce new constraints on the sequence design and increase the demands on the gradient system. The purpose of this paper is to demonstrate techniques for optimization of gradient echo gradient moment nulling sequences within the constraints of the gradient hardware. Flow compensated pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. The design of the gradient moment nulling sequences requires the solution of a linear system of equations. A Mathematica package was developed that interactively solves the gradient moment nulling problem. The package allows the physicist to specify the desired order of motion compensation and the duration of the gradients in the sequence with different gradient envelopes. The gradient echo sequences with first, second, and third order motion compensation were implemented with minimum echo time. The sequences were optimized to take full advantage of the capabilities of the gradient hardware. The sequences were used to generate images of phantoms and human brains. The optimized sequences were found to have better motion compensation than comparable standard sequences.

  • PDF

스크류운동을 하는 자유형상 물체의 스웹볼륨 계산을 위한 추적법의 응용 (Applying a Tracing Method to Compute Swept Volumes Generated by Free-form Objects in Screw Motions)

  • 김형규;김재정
    • 한국CDE학회논문집
    • /
    • 제15권2호
    • /
    • pp.106-114
    • /
    • 2010
  • The swept volume, the region of a moving object, is applied in many fields such as valid paths for motions of tools, visualization in robot paths and interference tests for parts assembling or disjointing. The shape of a swept volume depends on an generators computed with normal vectors of an object and velocity vectors of a motion. Although free-from surfaces are widely used to represent geometric models in CAD, computing the generators for a free-form object is a formidable task. Previous approaches exploit the closed form expressions of generators but limited to planer or quadric faces. In this paper, we propose the algorithm to compute swept volumes generated by free-form objects in screw motions. For the algorithm a tracing method is applied to the computation of generators. It considers curvatures of surfaces of an object to increase the computational accuracy. We implemented our algorithm in the CATIA V.5 environment to test the validity of our algorithm and to generate examples.

강진지속시간 기준 개선을 위한 원전 격납구조물의 지진응답해석 (Seismic Response Analysis of NPP Containment Structures to Improve the Guidelines of Strong Motion Duration)

  • 허정원;정호섭;김재민;현창헌
    • 한국지진공학회논문집
    • /
    • 제15권4호
    • /
    • pp.33-43
    • /
    • 2011
  • 이 논문은 원전구조물의 내진설계에 적용되는 인공지진파의 강진지속시간과 포락함수에 대한 현행 국내 설계기준의 개선과 보완을 위해서 필요한 기반연구에 관한 내용을 다루고 있다. USNRC와 ASCE 4-98에서 제안한 응답스펙트럼과 강진지속시간에 대한 규정이 현재 통상적으로 사용되고 있으며, 첫 번째로 두 기준에 대한 비교와 검토를 수행하였다. 다음으로 총 209개의 암반사이트에서 실제 계측된 규모 5.0 이상인 강진기록을 ASCE 4-98의 강진지속시간기준에 적용한 결과를 통계 처리하여 지진규모에 대한 함수로 표현되는 강진지속시간의 실험적 예측모델을 제시하였다. 마지막으로 강진지속시간이 원전구조물의 지진응답특성에 미치는 영향을 파악하기 위하여 6초에서 20초까지 약 2초 간격으로 강진지속시간을 달리하는 10가지 Case에 대한 인공지진파를 각 30개씩 작성하고, 이들을 적용하여 대만 Hualien 지진시험구조물과 국내 울진 원자력발전소 원자로 격납구조물에 대한 광범위한 지진응답해석을 수행하고 그 결과를 분석하였다.

악관절 폐구성 과두걸림 환자의 하악운동에 관한 연구 -치료전후의 하악운동 범위 및 양상 - (A Study on the Mandibular Movements in the Patients with TMJ Lock Closed -Range and pattern of mandibulr movement-)

  • Sung-Chang Chung;Hyung-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제16권1호
    • /
    • pp.113-120
    • /
    • 1991
  • The authors examined the patterns and various ranges of mandibular movements in TMJ lock closed patients in the frontal, sagittal and horizontal plane pre-end post-treatment. And the author obtained the following results. 1. In the frontal plane, the patterns and ranges of mandibular movement of the patients were very irregular and small before treatment. But after the treatment, the patterns were similar to the typical shield shape of the normal subjects. And the velocity of opening and closing was improved after the treatment. 2. In the sagittal plane, the mean amount of maximum mouth opening was 27.0±4.0mm before treatment and 44.0±5.4mm after treatment. And there was statistically significant improvement(p<0.005). The patterns of the movement were very irregular and small before treatment, but were similar to the shape of "Posselt's envelope of motion" after the treatment. The velocity of opening and closing was improved after the treatment 3. In the horizontal plane, the mean amount of maximum laterotrusion was 8l2±2.5mm in the affected side and 6.7±2.2mm in the non-affected side before treatment. There was a significant difference between the sides(p<0.05). After the treatment, the mean was 10.4±2.6mm in the affected side and 8.9±2.3mm in the non-affected side and there was no significant difference between the sides(p>0.05). There was no significant difference in the mean amount of maximum protrusion between the before and aftertreatment(p>0.05), but the patterns of the movements were improved.

  • PDF

A Study on Loading Arm Envelope and Alarm Setting according to Ship Movement

  • Choi, Byoung-Yeol;Jo, Hyo-Jae;Choi, Han-Sik;Choi, Dong-Eon
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권3호
    • /
    • pp.115-123
    • /
    • 2018
  • This study was carried using the new approach method to design appropriately the Loading Arm length and the alarm setting according to ship movements on Loading and Unloading marine Berth. The quasi-static mooring analysis was performed to estimate 110,000DWT ship's movements based on environmental conditions such as wind, current and wave. The mooring motion of the ship is very important to determine the loading arm scope, and in this case, the operation condition is performed on the ship without considering the damaged condition of the mooring line because the ship movement in case of damage is larger than intact, and all operations are stopped, the loading arm being released due to control system. From the result of mooring analysis, motion displacements, velocities and accelerations were simulated. They were used to simulate the maximum drifting speeds and distances. The maximum drifting speeds were checked to be satisfied within drifting speed limits. The total maximum drifting distances were simulated with alarm steps of the new approach method. Finally, the loading arm envelopes using the total maximum drifting distances were completed. Therefore, it was confirmed that the new approach method for loading arm envelopes and alarm settings was appropriate from the above results. In the future, it will be necessary to perform the further advanced dynamic mooring analysis instead of the quasi-static mooring analysis and to use the precise computer program analysis for various environments and ship movement conditions.