• Title/Summary/Keyword: engineering site

Search Result 7,648, Processing Time 0.032 seconds

Impact of Work stopped on Site Productivity and Productivity Achievement Ratio (작업중단이 현장 생산성과 생산성달성율에 미치는 영향)

  • Kim Tae-Wan;Yu Jung-Ho;Lee Hyun-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.311-314
    • /
    • 2003
  • This study takes a statistical approach to quantify tile impact of wort stopped on the following day's site productivity. Therefore, this study is aimed to verify this null hypothesis: 'A work stopped in a construction field does not impact on the following day's productivity and productivity achievement ratio'. For the purpose, work, stopped is presumed as a dummy variable impacting site productivity in multiple linear regression analysis. Moreover, the quantified impact of work slopped on productivity achievement ratio is identified based on this study. This study shows that construction managers should persevere in their efforts to secure the work continuity in order to improve site productivity and productivity achievement ratio.

  • PDF

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

Characteristics of Anchor Behavior Resisting Buoyancy Forces in the Weathered Rock (풍화암에 시공된 부력저항 앵커의 거동특성)

  • Yoo, Nam-Jae;Lee, Gun-Chag;Jeong, Gil-Soo;Park, Byung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.698-705
    • /
    • 2005
  • This study contains actual scaled site experiments on mediation factors affecting ultimate pulling force of the buoyancy resisting anchor which is installed underground water level suffering buoyancy force and breaking mechanism. Site buoyancy test selected the buoyancy acting site where acting buoyancy to the station structure since the stream and reservoir is neighboured to the vicinity ground and executed site experiments leading to variation of anchoring length, drilling diameter and tendon diameter at the weathered rock ground. The test result showed that pulling force getting increased more and more proportionate to increase of anchoring length, drilling diameter and tendon diameter, and as a result of analysis for correlations between anchoring length-ultimate limited load and drilling diameter-ultimate load (on the basis of 254mm settlement), modulus of correlation showed very high relation 0.9 and 0.99 respectively and correlation formular showed the limited load is increasing proportionate to cubic meters of anchoring length as well as the ultimate load proportionate to alignment of drilling diameter. It is also showed that limited load increased about 42.5% from 392kN to 559kN as a result of change the tendon diameter to 36mm and 50mm.

  • PDF

An Experimental Study on Penetration Resistance of Styrofoams Mounted on Falling Prevention Net for Re-bar (스티로폼이 거치된 낙하물방지망의 철근 낙하에 대한 관통 저항성 실험)

  • Son, Ki-Sang;Jeon, Soo-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.95-98
    • /
    • 2012
  • There are many high-rise apartment building construction in Korea. There was an accident to pass through worker head by rebar dropped from height place. Therefore, low cost-high effectiveness method to prevent this type of accident should be revised and applied into the construction site. This study is to find out which method could be effectively applied to a site with low cost. Practical field test at 4th floor, 10th floor of apartment building site using re-bar diameter D10, D13, D16, D19, D22 with a length of 1 m, 1.5 m, 2 m, 2.5 m, 3 m which are common by used in a site. The test has also been done with a cover of styrofoam thickness 4.5 cm and thickness 9cm on field drop preventing net. One sheet of styrofoam thickness 45 mm has approximately two times stronger than only prevention net, It is found. Also, Two sheets have approximately two times stronger than one sheet of it.

Noise Map Analysis for the Design of Noise Barrier at School Site (학교부지의 방음벽 설계를 위한 소음지도 해석)

  • Yun, Junho;Kim, Wonjin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.4
    • /
    • pp.232-238
    • /
    • 2012
  • In this study, the noise mapping simulation is executed to design an effective barrier reducing noise levels of a school site. The geographical features of the ambient site and the school buildings are modelled in detail in order to consider sound propagation, deflection, and absorption phenomena etc. The main sound source, sound power level of expressway, is estimated on the basis of measured noise levels at several points of the site. The noise mapping simulation is performed by using ENPro, environmental noise prediction program based on ISO 9613 to analysis the effectiveness of noise barrier. Consequently, the noise barrier is designed to meet an environmental noise standard and satisfy low cost and safety conditions.

A Study on the Construction and Site Selection of the Cloud Data Center considering Disaster Information (재해정보를 고려한 클라우드 데이터센터 입지선정에 관한 연구)

  • Kim, Ki-Uk;Kim, Chang-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2575-2580
    • /
    • 2012
  • The aim of this paper is to analyze factors for site selection of the cloud data center and to develop spatial data model considering disasters information based on the GIS. In this paper, historical areas of the natural and human disaster are considered to analyze location of the cloud center. The model is developed using ArcGIS S/W tool. The model is applied on Busan city using disaster data from storm and flood, and small administrative district located Kang-Seo-Gu is selected as site selection of the cloud data center of Busan.

A Study on Use of Radar Rainfall for Rainfall-Triggered Mud-Debris Flows at an Ungauged Site (미계측 지역에서 토석류 유발강우의 산정을 위한 레이더 강우의 활용에 대한 연구)

  • Jun, Hwandon;Lee, Jiho;Kim, Soojun
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.310-317
    • /
    • 2016
  • It has been a big problem to estimate rainfall for the studies of mud-debris flows because the estimated rainfall from the nearest AWS (Automatic Weather Station) can tend to be quite inaccurate at individual sites. This study attempts to improve this problem through accurate rainfall depth estimation by applying an artificial neural network with radar rainfall data. For this, three models were made according to utilizing methodologies of rainfall data. The first model uses the nearest rainfall, observing the site from an ungauged site. The second uses only radar rainfall data and the third model integrates the above two models using both radar and observed rainfall at the sites around the ungauged site. This methodology was applied to the metropolitan area in Korea. It appeared as though the third model improved rainfall estimations by the largest margin. Therefore, the proposed methodology can be applied to forecast mud-debris flows in ungageed sites.

Stochastic ground-motion evaluation of the offshore Uljin Earthquake (울진앞바다 지진( '04. 5. 29, M=5.2)의 추계학적 지진동 평가)

  • Yun, Kwan-Hee;Park, Dong-Hee;Choi, Weon-Hack;Chang, Chun-Jung
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.18-25
    • /
    • 2005
  • Stochastic ground-motion method is adopted to simulate horizontal PGA values for the offshore Uljin earthquake recorded at nationwide seismic stations. For this purpose, the Fourier spectra are calculated at every stations based on comprehensive results of wave propagation and site effect which were previously revealed through inversion process applied to large accumulated spectral D/B. In addition, the apparent source spectrum of the offshore Uljin earthquake is estimated by removing the path and site response from the observed spectra. The distance dependent time-duration model is revised by iteratively fitting the PGA values generated by using the raw spectra data to the observed PGA data. The stochastic ground-motion method predicts the observed PGA values within a error of ${\sigma}_{log10}=0.1$. Transfer functions of a site relative to another site are estimated based on the error residual of the inversion results and used to convert PGA values at multiple stations to expected PGA values at a reference station of TJN. The converted PGA values can be used as basic data to evaluate the ground-motion attenuation relations developed for seismic hazard analysis that concerns the large damaging earthquakes.

  • PDF

Structural characteristics and electronic properties of GaN with $N_V,\;O_N,\;and\;N_V-O_N$: first-principles calculations

  • Lee, Sung-Ho;Chung, Yong-Chae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.5
    • /
    • pp.192-195
    • /
    • 2007
  • Structural and electronic properties of bulk GaN with nitrogen vacancy($V_N$), oxygen substitution on nitrogen site($O_N$), and complex of nitrogen vacancy and oxygen substitution on nitrogen site($V_N-O_N$) were investigated using the first principle calculations. It was found that stability of defect formation is dependent on the epilayer growth conditions. The complex of $V_N-O_N$ is energetically the most favorable state in a condition of Ga-rich, however, oxygen substitution in nitrogen site is the most favorable state in N-rich condition. The electronic property of complex with negative charge states at $\Gamma$ point was changed from semiconductor to metal. On the contrary, the properties of nitrogen vacancy except for neutral charge state have shown the semiconductor characteristics at $\Gamma$ point. In the oxygen substitution on nitrogen site, the energy differences between conduction band minimum and Fermi level were smaller than that of defect-free GaN.

Case Study of Wind Farm Design Using OpenWind - Youngdeok Wind Farm (OpenWind를 이용한 풍력단지설계 사례연구 -영덕풍력단지)

  • Kim, Hyun-Goo;Hwang, Hyo-Jeong;Kim, Ju-Hyun;Ko, Soo-Hee;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1169-1175
    • /
    • 2010
  • A case study for the design of a wind farm in complex terrain was carried out using the wind farm site analysis software OpenWind, which has an open-source platform and is free to use. The Youngdeok Wind Farm, constructed on mountainous terrain in Korea, was chosen as a model site; the design process reproduced using OpenWind. A comparison of the positions of the wind turbine derived from the OpenWind optimization process and the current positions were in good agreement. The annual energy production predicted by OpenWind compared with the prediction by the micrositing software, WindSim, were also validated to within 1%. Therefore, it was confirmed that OpenWind can be used for a practical wind farm design project. It is also anticipating that this paper will provide a prototype process for the design of a wind farm site and offer a database for the post-evaluation of a constructed wind farm in Korea.