• Title/Summary/Keyword: engineering room

Search Result 4,561, Processing Time 0.037 seconds

A Study on the Pressure Change during the Pressurization to the Elevator Lobby (부속실 급기가압 시 압력특성 변화에 관한 연구)

  • Kim, Beom-Kyue;Park, Yong-Hwan;Kim, Hong-Sik
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2012
  • This study investigated the pressure change in the fire room and elevator lobby during the air pressurization to the Elevator lobby with the various egress scenarios and the existence of vent holes in the fire room. The experiments revealed that pressure change was significantly affected by the open/closure scenarios of the front door and stairway door resulting in over pressure, under pressure and performance drop of the door closure. It also revealed that the required smoke defensive air velocity can be obtained only with the existence of vent holes in the fire room by the removal of back pressure in the fire room.

Hazard analysis by fire simulation in an apartment fire (화재 시뮬레이션을 이용한 아파트 화재 위험성 분석)

  • Kim, Tae Kwon;Cha, Woo Sub
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-388
    • /
    • 2014
  • This study predicts damaging risk factors in apartment fire situation by using CFAST. The software was developed by Building and Fire Research Lab, that is government affiliated organization of the National Institute of Standards Technology. This analysis scenarios werec well verified by experimental results. Situation of the living room and the second room as well as the bedroom tends to be qualitatively the same with the experimental data. In case of apartment fire, it is predicted that they have been got into trouble with dizziness, badly vomiting and paralysis symptoms due to short oxygen and excessive carbon dioxide when persons were left out in the living room or second room.

A study on the effect of ground conditions of room and pillar method on pillar and room strain (격자형 지하공간의 지반조건이 암주와 룸 변형률에 미치는 영향에 대한 연구)

  • Ham, Hyeon Su;Kim, Yong Kyu;Park, Chi Myeon;Lee, Chul Ho;Kim, YoungSeok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.577-587
    • /
    • 2021
  • Room and Pillar method is an underground facility construction method that maximizes the strength of the in-situ ground. In order to secure the safety of the underground space, it is necessary to secure the safety of the room actually used in addition to the safety of pillar of the room and Pillar method. In this study, the evaluation method for the safety of the room and rock pillar in the room and pillar method was studied through numerical analysis. Numerical analysis was performed for a total of 125 cases using ground conditions, pillar width, and room width as parameters, and the results were derived. As for the safety factor of the pillar, it was confirmed that the safety factor increased when the strength of the ground increased, and it was confirmed that the increment in the safety factor decreased when the width of the pillar was widened. The room strain was evaluated by applying the Critical strain. As the width of the pillar became narrower, the Critical strain was higher, and as the width of the room became smaller, the Critical strain was smaller. As a result of the correlation analysis between the safety factor of the pillar and the room strain, it was possible to derive the upper limit of the room strain that can secure the standard safety factor of the pillar according to the width of the pillar. It is judged that the results derived from this study can be used as a guideline to secure the safety of the room when the actual design is performed in consideration of the ground conditions and room width.

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.

Development of Temperature Control System for Cold Storage Room Using Fuzzy Logic (퍼지논리를 이용한 저온저장고의 온도제어시스템 개발)

  • 양길모;고학균;조성인
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.107-114
    • /
    • 2000
  • Low temperature storage method is to increase the value of agricultural products by reducing quality loss and regulate consignment time by controlling respiration rates of agricultural products. Respiration rate of agricultural products depends on several factors such as temperature, moisture, gas composition and a microbe inside the storage room. Temperature is the most important factor among these, which affects respiration rate and causes low or high temperature damage. Fuzzy logic was used to control the temperature of a storage room ,which uses information of uncertain facts and mathematical model for room temperature control . Room temperature was controlled better by using fuzzy logic control method rather than on-off control method. Refrigerant flow rates and temperature deviations were measured for on-off system using TEV(temperature expansion valve) and for fuzzy system using EEV(Electrical Expansion Valve) . Temperature of the Storage room was lowered faster by using fuzzy system than on -off system. Temperature deviation was -0.6~+0.9$^{\circ}C$ for on-off system and $\pm$0.2$^{\circ}C$ for fuzzy system developed. Temperature deviation and variation of temperature deviation were used as inout parameters for fuzzy system. The most suitable input and output value were found by experiment. Cooling rate of the storage room decreased while temperature deviation increased for the sampling time of 20 sec.

  • PDF

Simulation of the Air Conditioning System Using Fuzzy Logic Control

  • Mongkolwongrojn, M.;Sarawit, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2270-2273
    • /
    • 2003
  • Fuzzy logic control has been widely implemented in air conditioning and ventilation systems which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters , several fuzzy logic controllers had been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control room temperature and humidity in the precision air conditioning systems. The nonlinear mathematical model was formulated using energy and continuity equations. MATLAB was used to simulate the fuzzy logic control of the multi-variable air conditioning systems. The simulation results show that fuzzy logic controller can reduce the steady-state errors of the room temperature and relative humidity in multivariable air conditioning systems. The offset are less than 0.5 degree Celsius and 3 percent in relative humidity respectively under random step disturbance in heating load and moisture load respectively

  • PDF

A New Driving Waveform to Improve Dark Room Contrast Ratio in AC Plasma Display Panel

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Ryu, Jae-Hwa;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.203-206
    • /
    • 2002
  • In this study, a new driving method is suggested to improve the dark room contrast ratio. The principles of the method are that the reset facing discharges occur between scan and address electrodes instead of surface discharge and that the discharge occurs only for the cells that experienced sustain discharge in preceding sub-field after the first sub-field. The dark room contrast ratio is improved more than 7 times compared with the conventional method.

  • PDF

Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room - (공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 -)

  • Kwon, Kyung-Woo;Cho, Si-Jin;Choi, Eui-Sung;Park, Jun-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

A Study on Improvement Effect of voice information transmission using Auralization at the hydraulic turbine dynamo room in Dam (가청화를 이용한 댐 수차 발전기실의 음성정보전달 개선효과에 관한 연구)

  • Kook, Joung-Hun;Ju, Duck-Hoon;Jung, Eun-Jung;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.263-267
    • /
    • 2007
  • Even though Waterpower Generation as pollution-free has its own merit of contribution by supply of good quality electricity, due to the noise made at the time of its operation, a normal mutual communication among the workers and technicians engaging at the hydraulic turbine dynamo room is almost impossible, and since those finishing materials had been used mainly by reflection material, it is actual situation that when working for maintenance in the hydraulic turbine dynamo room, as counterpart's voice vibrates, its working efficiency is difficult to ensure. On such view point, this Research has conducted Psycho-acoustics Experiment about voice Definition using Auralizational Technique, on the object for the hydraulic turbine dynamo room that improved its acoustic performance by computer simulation. As the result of Study, it was known that the clearness of sound with regard to voice information transmission was apparently improved in all items than before improvement. Therefore, it is considering that these results would be utilized usefully when renovation on the hydraulic turbine dynamo room in the future.