• 제목/요약/키워드: energy usage

검색결과 973건 처리시간 0.033초

A study on method for improving renewable energy supply ratio for the school building applied PV system (태양광발전 시스템이 설치된 학교건물의 신재생에너지 공급비율 증가방안에 관한 연구)

  • Kim, Seok-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • 제33권2호
    • /
    • pp.42-49
    • /
    • 2013
  • Recently, the attention to renewable energy has increased globally because of the environmental issue and the global energy crisis. Accordingly, south korea is focused on increasing the renewable energy usage. And the government enforced a law to the public buildings to install the renewable energy facilities. In this study, the building to evaluate renewable energy consumption and supply ratio was selected. This building has 9.79% of renewable energy supply ratio by PV system. In this study, the method for improving renewable energy supply ratio was analyzed using additional PV system. And The 5 methods to increasing electricity were evaluated. The method of increase 4.24 times PV arrays area is most efficient way to increase the renewable supply ratio. The case 1, show that the increasing renewable energy supply ratio of 39.2% compared to exsiting PV system. The result of the above, consider the additional supply of renewable energy.

Recent Progress in Solar Energy Research - A review of Papers Published in the Korean Journal of Solar Energy between 2000 and 2002 - (태양에너지 분야의 최근 연구동향- 2000년$\sim$2002년 학회지 논문에 대한 종합적 고찰 -)

  • Yoo, Ho-Chun;Jang, Moon-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • 제22권4호
    • /
    • pp.107-119
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Solar Energy between 2000 and 2002 has been done. Focus has been put on current status of research in the aspect of Insolation. Solar Collector and Storage System, Solar Heating and Cooling System, Solar Cell and Lighting System, Active and Passive Solar Building, Heat Transfer in Solar Energy and Natural Energy. The conclusions are as follows. 1) Many studies on Insolation were conducted to optimize the usage of Solar Energy. 2) A review of the recent studies on solar thermal shows that there were many papers on solar collector and storage system. However, studies on the HVAC system using solar energy were relatively insufficient. 3) To produce high efficient solar cell. various experimental and numerical papers were published. However studies on control system, solar cell and lighting were seemed to be insufficient. 4) Studies on using solar energy in passive solar buildings were widely carried out, however, studies based on synthetic analysis of buildings and BIPV were insufficient. 5) Studies on heat transfer were mainly about heat exchanger, performance of heat pipe and multi air conditioner. 6) Studies on energy resources except for solar energy, such as hydraulic power and wind power etc. were very few.

A Study on Effect Analysis of Integrated Demand Management According to Energy System Management Model (Energy System Management 모형을 통한 통합 수요관리 효과분석에 관한 연구)

  • Kim, Yong-Ha;Jo, Hyeon-Mi;Kim, Young-Gil;Park, Hwa-Yong;Kim, Hyeong-Jung;Woo, Sung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제60권7호
    • /
    • pp.1339-1346
    • /
    • 2011
  • This paper is developed to demand management scenario of energy consumption efficiency improvement, electricity generation efficiency improvement, network efficiency improvement, change of distribution ratio, movement of energy source, change of heating system, put of CHP to quantitatively assess to impact on energy use of demand management at the national level. This scenario can be applied Energy System Management model was developed based on Energy Balance Flow. In addition, effect analysis through built demand management scenario was quantitatively evaluated integrated demand management effectiveness of energy cost saving, CO2 emission reduction and energy savings of national level by calculating to primary energy source usage change in terms of integration demand management effect more often than not a single energy source separated electricity, heat and gas.

A Case Study on Energy Performance Analysis of Retrofitted Building Using Inverse Model Toolkit (Inverse Model Toolkit을 이용한 리모델링 건축물의 에너지 성능평가 사례)

  • Kwon, Kyung-Woo;Lee, Suk-Joo;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제26권8호
    • /
    • pp.394-400
    • /
    • 2014
  • Several models and methods have been developed to verify the improvement of energy performance in retrofit buildings. The verification is important to confirm the effectiveness of new technologies or retrofits. Inverse model toolkit proposed by ASHRAE evaluates the changes of the energy performance of retrofit buildings by using actual energy consumption data. In this study, the inverse model toolkit was used to analyze heating and cooling energy performance of an office building. Analyzed coefficients of correlation of actual energy consumption with estimated energy consumption was above 0.92 and well fitted. It was confirmed that energy consumption of natural gas decreased by 43.4% and also that electricity decreased by 13.8%, after the retrofit of the case building. For the energy usage, cooling energy was increased by 7.4%, heating energy was decreased by 42.3%, hot water and cooking were increased by 3.4%, lighting and electronics were decreased by 19.3%, and the total energy was decreased by 18.9%.

A Study on the Implementation Issues for Demand-side Management of Energy Suppliers (에너지공급자 수요관리 개선방안 연구)

  • Kim, Hyeong-Jung;Son, Hag-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제59권9호
    • /
    • pp.1566-1574
    • /
    • 2010
  • This paper presents an in-depth review for current status for demand-side management (DSM) investment of energy supplier and an useful prospect on the introduction of Energy Efficiency Resource Standards (EERS). According to the Article 9 of Rational Energy Utilization Act, Energy suppliers-Korea Electric Power Corporation (KEPCO), Korea Gas Corporation (KOGAS) and Korea District Heat Corporation (KDHC) prescribed by Presidential Decree-must establish and implement annual demand-side management investment plan to improve energy efficiency in production, transformation, transportation, storage and usage of corresponding energy and to reduce demand and green house gas emissions. In this paper, we examine the DSM programs of energy suppliers and the results of DSM investment in 2009, then we propose a reasonable solution for the development of DSM investment. Furthermore, in order to compare our situation, the case studies were conducted on EERS issues in England, Italy, France and U.S, such as establishing the energy saving target, selecting the target energy supplier, and penalty and incentive mechanisms. Throughout the case studies, this paper suggests the directions to the DSM investment planning of energy suppliers and the major issues to prepare EERS in Korea.

A Study on Analysis of Energy Consumption of the Middle School Facilities in Korea (전국 중학교 시설의 에너지 사용실태 분석 연구)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.45-50
    • /
    • 2010
  • This study for middle school facilities is second following the study of the energy consumption of primary school facilities. There is not on the analysis of the current energy usage for middle school facilities in nations to set goals of energy reduction. Therefore, The purpose of this study is to present various analysis result of energy consumption which is a statistical analysis of domestic middle school facilities in South Korea. As a consequence, each average energy consumption at the domestic middle school facilities analyzed as following after changing as unit 'kWh' only for comparison with every energy source. It represents that the energy consumption of electric power was 183.7MWh(70.2%), gas consumption for heating was 46.5MWh(17.8%), oil consumption was 26.5MWh(10.1%), district energy was 5.1MWh(1.9%). This result describes that consumption of electric power was large greatly and it reflects the expectation that it will climb the demand regarding this energy in the future. In additionally, it analyzed average energy consumption with $74.4kWh/m^2$ by the unit area of air-conditioning and the district which has large energy consumption was Seoul with $91.6kWh/m^2$.

Studies on the method and the theory of moxibustion in "BianQueXinShu(扁鵲心書) (vol. I)" ("편작심서(扁鵲心書).권상(卷上)"에 나타난 뜸법에 대한 연구(硏究))

  • Kim, Hyun-Dong;Lee, Yong-Bum
    • Journal of Korean Medical classics
    • /
    • 제20권2호
    • /
    • pp.175-193
    • /
    • 2007
  • A theory of the school which attach great importance to moxibustion therapy was more developed from 'Ge Hong(葛洪)', 'Wang Tao(王燾)' up to "BianQueXinShu(扁鵲心書)" of 'Dou Cai(竇材)' in Song Dynasty. The first volume of "BianQueXinShu" was described about the principles of health preserving method, diagnosis, treatment related with meridian system, support Yang theory, moxibustion therapy over the 10 chapters and in the continued 3 chapters, explained the symptoms and related moxibustion therapies. The summary is as follows. The Yang energy is the essence of the human body and it is minutely explained in "Hwangdineijing(黃帝內經)". However, the younger scholars after 'Zhang Zhongjing(張仲景)' held different views with "Hwangdineijing" so they didn't control serious diseases. Supporting the Yang energy, it will be possible to human body in good health and long life and perennial youth and longevity. To do like this, the first important thing is a moxibustion, the second is a Taoist hermit medication(丹藥) and the third is well usage of Radix Aconiti Lateralis Preparata. According to the sequence of Yang energy deficiency, the stages of diseases are classified as Ordinary Gi(平氣), Latter deficient state(微虛), The more deficient state(甚虛), Exhausting state(將脫), Exhausted state(已脫) and in the consideration of each stage, it is used gradually with warm-natured berbs, warm-acrid herbs, warm-heated herbs and moxibustion therapy. If it comes to the stage of Exhausted state, the Yang energy is too weak to treat a disease. Therefore it is easy to harm human body with usage the treatment of the Purgationist school theory or the Cold and cool medical school theory, so it is needed a great attention to use these therapies. To summarized the keynote of 'Du Jae''s moxibustion therapy, the one is a minority of selection of points(1$^{\sim}$2 acupuncture points), the second is a majority of moxibustion units(50$^{\sim}$500 units), and the other is a focused selection of points on spleen and kidney(especially Gwanwon, CC4). And in this book, it was explained concretely about the size of moxibustion, according to the experiment with mentioned size, the burning time of moxibustion was almost 4 min 40 sec, so the big size moxibustion was one of the characteristic of moxibustion therapy revealed in this book. Also it was used 'Suseongsan(睡聖散)' - a kind of analgesic herb complexes - to reduce a pain during the usage of moxibustion therapy in this book. To develop the moxibustion theory, it is more investigated in the future that there wasn't significant relation between Gwanwon(CC4) and spleen and kidney meridian in theory, compared to many used Gwanwon(CC4) in the prescription, where as mentioned the importance of spleen and kidney in treatment, that considering the burning time(1 unit - 4 min 40 sec, 12 units an hour, maximum 288 units a day) there were no guidances about meals, sleeping, stool and urine, and that there was no concrete study about the toxicity of 'Suseongsan' as analgesic moxibustion therapy.

  • PDF

A study on technical application of recycle energy storage system for electric rail car (전동차 회생에너지 활용을 위한 저장시스템 적용기술 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Oh, Se-Chan;Lee, Chang-Mu
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.307-309
    • /
    • 2006
  • There are operated the six thousand train in the interior of a country. 95% of them are possible usage of resuscitation. Especially, Among them VVVF-Inverter vehicle has a merit of the highest recycle rate. but we don't use a apt recycled energy. Although the existing recycle energy used inverter method supply with electric power, it is decided in accordance with the state of sources. So efficiency of recycled electric power is of poor quality and catenary-voltage-fluctuation be generate because of recycled electric power. and it is able to affect system of safety train service. We'll research the method of supply according to wire condition after storing recycle energy made during train's stopping relation to Advanced EMU Research. Those methods are divided SMES, Fly-Wheel and Supercapacitor, and Considering the both economical efficiency and system application, we'll develop recycle energy storage system suitable our country condition.

  • PDF

A study on the Distribution Estimation of Residental Refrigerators using Bass Diffusion Model and Economic Analysis Corresponding to Enhancement of Energy Efficiency (Bass 확산모형을 이용한 가정용 냉장고의 보급추정 및 효율향상에 따른 경제성 분석 연구)

  • Baek, Jung-Myoung;Won, Jong-Ryul;Lee, Byung-Ha;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제57권11호
    • /
    • pp.1938-1945
    • /
    • 2008
  • Due to rapid economic growth, the usage of residential cooling electrical appliances such as air conditioners and refrigerators has increased dramatically for the last decades. In other to reduce its energy consumption, the authorities have applied energy efficiency standards for principal appliances, including refrigerator. This paper estimates the distribution of refrigerators using the Bass Diffusion Model and then performs economic analysis corresponding to enhancement of energy efficiency more correctly than existing methods.

A Study on Realization Method of Low Carbon School Building (저 탄소 학교건축물 구현 방안에 관한 연구)

  • Tae, Sung-Ho;Cho, Young-Sang;Shin, Sung-Woo;Lee, Seung-Min;Meang, Joon-Ho
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • 제9권2호
    • /
    • pp.30-37
    • /
    • 2010
  • This study purposed realization and a phase reduction of school building $CO_2$ emissions. Accordingly selected standard school buildings and evaluated life cycle environmental load($CO_2$). This study proposed Green building technology which separated design sector, energy sector, afforestation sector for carbon-neutral city school buildings realization of M-city. As a result, elementary, middle and high schools of M-city built in the year 2013 were required that design sector was Energy Performance Index(EPI) 75 point and energy sector was solar installations more than 25% of the power usage, Solar systems installed more than 10% of total gas consumption and the area of afforesting more than 35% of the ecological area to achieve 30% $CO_2$ reduction compared to the Respectively standard school buildings.