• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.033 seconds

The Comparison of Characteristics of Trunk Motion between Energy Walking and Normal Walking (에너지보행과 일반보행에서 몸통운동의 특성 비교)

  • Shin, Je-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.133-145
    • /
    • 2007
  • The purpose of this paper was to compare of difference between energy walking and normal walking. Subjects were selected 8 male undergraduates. The kinematic variables of a pelvis and a thorax were analysed at the take off and contact with 3d cinematography. In addition to the variables, the phase plot angle was calculated in order to definite characteristics in the phase space. The pelvic angle and angular velocity showed significant differences in the flexion/extension between two walking patterns. The pelvic angle and angular velocity were increasing when walking speed was increasing and magnitude of the variables of energy walking was larger than corresponding values for normal walking. On the other hand, the thoracic angle demonstrated significant differences in the flexion/extension and rotation between two walking patterns. The angles of energy walking were smaller in the flexion/extension and were larger in the rotation than the angle of normal walking. The kinematic characteristics of energy walking were also showed clearly significant differences in the range of motion and the relative angle of the trunk. The angle of phase plot only showed demonstrated a significant difference in the rotation at contact between the two walking patterns.

Design Study of LAR Tokamak Reactor with a Self-consistent System Analysis Code

  • Hong, B.G.;Lee, D.W.;Kim, S.K.;Kim, D.H.;Lee, Y.O.;Hwang, Y.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.314-314
    • /
    • 2010
  • The design of the blanket and shield play a key role in determining the size of a reactor since it has an impact on the various reactor components. The blanket should produce enough tritium for tritium self-sufficiency and the shield should provide sufficient protection for the superconducting TF coil. Neutronic optimization of the blanket and the shield is necessary, and we coupled the system analysis with a neutronic calculation to account for the interrelation of the blanket and shield with the plasma performance of a reactor system in a self-consistent manner. By using the coupled system analysis code, the operational space for a low aspect ratio (LAR) tokamak reactor with a superconducting toroidal field (TF) coil is investigated with an spect ratio in the range of 1.5 - 2.5. The minimum major radius which satisfies all the physics and engineering requirements increases with the magnetic field at the magnetic axis. A required inboard shield thickness is mainly determined by the requirement on the protection of the TF coil against radiation damage. It is shown that to have a fusion power bigger than 3,000 MW in the LAR tokamak with a superconducting TF coil, a major radius bigger than 4.0 m is required.

  • PDF

Synthesis of Electroplated 63Ni Source and Betavoltaic Battery (63Ni 도금선원 및 베타 전지 제조)

  • Uhm, Young Rang;Yoo, Kwon Mo;Choi, Sang Mu;Kim, Jin Joo;Son, Kwang Jae
    • Journal of Radiation Industry
    • /
    • v.9 no.4
    • /
    • pp.167-170
    • /
    • 2015
  • Radioisotope (Nuclear) battery using $^{63}Ni$ was prepared as beta cell. The electroplated $^{63}Ni$ on Ni foil is fabricated, and beta cell and photovoltaic hybrid battery was designed to use at both day and night in space project. A Ni-plating solution is prepared by dissolving metal particles including $^{62}Ni$ and $^{63}Ni$ from neutron irradiation of ($n,{\gamma}$). Electroplating solution of a chloride bath consists on nickel ions in HCl, $H_3BO_3$, and KOH. The deposition was carried out at current density of $10mA\;cm^{-2}$. The prepared beta source was attached on a PN junction and measured I-V properties. The power output at activity of 0.07 mCi and 0.45 mCi were 0.55 pW and 2.69 nW, respectively.

A Study on Correlation Peel Strength and the Efficiency of Shingled Modules According to Curing Condition of Electrically Conductive Adhesives (슁글드 모듈에서 경화조건에 따른 ECA 접합강도와 효율의 상관관계에 관한 연구)

  • Jun, Dayeong;Son, Hyoungin;Moon, Jiyeon;Cho, Seonghyeon;Kim, Sung hyun
    • Current Photovoltaic Research
    • /
    • v.9 no.2
    • /
    • pp.31-35
    • /
    • 2021
  • Shingled module shows high ratio active area per total area due to more efficient packing without inactive space between cells. The module is fabricated by connecting the pre-cut cells into the string using electrically conductive adhesives (ECA). ECAs are used for electric and structural connections to fabricate the shingled modules. In this work, we investigated a correlation between ECA peel strength and the efficiency of pre-cut 5 cells module which are fabricated according to ECA interconnection conditions. The curing conditions are varied to determine whether ECA interconnection properties can affect module properties. As a result of the peel test, the highest peel strength was 1.27 N/mm in the condition of 170℃, the lowest peel strength was 0.89 N/mm in the condition of 130℃. The efficiency was almost constant regardless of the curing conditions at an average of 20%. However, the standard deviation of the fill factor increased as the adhesive strength decreased.

Fabrication of Shingled Design Solar Module with Controllable Horizontal and Vertical Width (가로세로 폭의 제어가 가능한 슁글드 디자인 태양광 모듈 제조)

  • Min-Joon Park;Minseob Kim;Eunbi Lee;Yu-Jin Kim;Chaehwan Jeong
    • Current Photovoltaic Research
    • /
    • v.11 no.3
    • /
    • pp.75-78
    • /
    • 2023
  • Recently, the installation of photovoltaic modules in urban areas has been increasing. In particular, the demand for solar modules installed in a limited space is increasing. However, since the crystalline silicon solar module's size is proportional to the solar cell's size, it is difficult to manufacture a module that can be installed in a limited area. In this study, we fabricated a solar module with a shingled design that can control horizontal and vertical width using a bi-directional laser scribing method. We fabricated a string cell with a width of 1/5 compared to the existing shingled design string cells using a bi-directional laser scribing method, and we fabricated a solar module by connecting three strings in parallel. Finally, we achieved a conversion power of 5.521 W at a 103 mm × 320 mm area.

A Critical Note on the Electric Field in Direct and Alternating Current and Its Consciousness

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.98-104
    • /
    • 2000
  • The conventional model did not take momentum conservation into consideration when the electron absorbs and emits the photons. II-ray provides momentum conservations on any directions of the entering photons, and also the electrons have radial momentum conservations and fully elastic bouncing between two atoms, in the new atom model. Conventional atom model must be criticized on the following four points. (1) Natural motions between positive and negative entities are not circular motions but linear going and returning ones, for examples sexual motion, tidal motion, day and night etc. Because the radius of hydrogen atom's electron orbit is the order of 10$^{-11}$ m and the radia of the nucleons in the nucleus are the order of 10$^{-14}$ m and then the converging $\pi$-gamma rays to the nucleus have so great circular momentum, the electron can not have a circular motion. We can say without doubt that any elementary mass particle can have only linear motion, because of the $\pi$-rays'hindrances, nearthenucleus. (2) Potential energy generation was neglected when electron changes its orbit from outer one to inner one. The h v is the kinetic energy of the photo-electron. The total energy difference between orbits comprises kinetic and potential energies. (3) The structure of the space must be taken into consideration because the properties of the electron do not change during the transition from outer orbit to inner one even though it produces photon. (4) Total energy conservation law applies to the energy flow between mind and matter because we daily experiences a interconnection between mind and body. Conventional Concept of Electric Field must be extended in the case of the direct and alternating current. Conventional concept is based on coulomb's force while the electric potential in the direct and alternating current is from Gibb's free energy. And also conventional concept has not any consciousness with human being but the latters has a conscious sensibility. The cell emf is from the kinetic energy of the open $\pi$-rays flow through the conducting wire. The electric potential in alternating current is from that the trans-orbital moving of the induced change of magnetic field in the wire produces flows of open $\pi$-rays, which push the rotating electrons on the orbital and then make the current flow. Human consciousness can induce a resonance with the sensibility of the open $\pi$-rays in the electric measuring equipment. Specially treated acupunctures with Nasucon is for sending an acupunctural effect from one place to another via space by someone's will power.

  • PDF

A Study on the HI Decomposition by Carbon-Supported Platinum Catalyst (백금담지 활성탄소 촉매의 요오드화수소 분해 특성 연구)

  • Park, J.E.;Kim, J.M.;Kang, K.S.;Kim, C.H.;Kim, Y.H.;Park, C.S.;Bae, K.K.
    • Journal of Hydrogen and New Energy
    • /
    • v.17 no.3
    • /
    • pp.301-308
    • /
    • 2006
  • The present work explores the effect of carbon-supported platinum catalyst on the HI decomposition using gas adsorption analyzer, thermogravimetry, X-ray diffractometry, scanning electron microscopy, and gas chromatography. For this purpose, three types of activated carbon (C), Pt/C-1 wt.%, and Pt/C-5 wt.% were prepared. The HI gas conversion is crucially influenced by the amount of Pt on the carbon support. The more the amount of Pt was, the higher results in the HI gas conversion. For three types of catalysts, HI conversion increased with increasing the decomposition temperature but with decreasing the space velocity. The increase of HI conversion with temperature was more pronounced in activated carbon than that in Pt/C. From EDX result, it was found that the activated carbon comprised higher amount of iodine than the Pt/C after the decomposition reaction. This implies that the HI conversion is closely related to the amount of Iodine.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Hydrogen Production from Pyrolysis Oil of Waste Plastic on 46-3Q Catalyst (46-3Q 촉매 상에서 폐플라스틱의 열분해 오일로부터 수소 제조 )

  • SEUNGCHEOL SHIN;HANEUL JUNG;DANBEE HAN;YOUNGSOON BAEK
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.601-607
    • /
    • 2023
  • Pyrolysis oil (C5-C20) produced using plastic non-oxidative pyrolysis technology produces naphtha oil (C5-C10) through a separation process, and naphtha oil produces hydrogen through a reforming reaction to secure economic efficiency and social and environmental benefits. In this study, waste plastic pyrolysis oil was subjected to a steam reforming reaction on a commercialized catalyst of 46-3Q And it was found that the 46-3Q catalyst reformed the pyrolysis oil to produce hydrogen. Therefore, an experiment was performed to increase hydrogen yield and minimize the byproduct of ethylene. The reaction experiment was performed using actual waste plastic oil (C8-C11) with temperature, steam/carbon ratio (S/C) ratio, and space velocity as variables. We studied reaction conditions that can maximize hydrogen yield and minimize ethylene byproducts.

Daylighting Performance of Office Space Applied with Electrochromic Façade System (전기변색 외피시스템 적용 업무공간의 채광 성능 분석)

  • Kim, Jae-Hyang;Han, Seung-Hoon
    • Land and Housing Review
    • /
    • v.13 no.1
    • /
    • pp.131-140
    • /
    • 2022
  • A smart window is a new building material that can realize energy savings in a building. Smart windows can freely adjust Visible Light Transmittance (VLT) and solar gain coefficient (g-value) according to the situation. Smart windows include such technologies as Electrochromic (EC), Suspended Particle Device (SPD), and Polymer Dispersed Liquid Crystal (PDLC). Recent research on building energy savings through the VLT and g-value control functions of smart windows is being actively conducted and meaningful results are being drawn. However, since most of the research is focused on energy savings, research on the indoor environment is somewhat lacking. A building is a space where people live and the comfort of life should be prioritized before energy savings. Therefore, in this study, analysis on the daylight performance of an office space was carried out. Through green building standards such as LEED, BREEAM, CASBEE, and G-SEED, the daylight performance was reviewed according to VLT value changes of the smart window. In addition, a study was conducted on the VLT range of the electrochromic façade that can maintain a comfortable indoor environment. The smart window used electrochromic control with a wide range of VLT. The study showed that the minimum VLT of a smart window that can satisfy G-SEED is 25% or more. In addition, it was found that the VLT change of the electrochromic smart window did not significantly affect the uniformity of the room. When the LEED standard was applied, the minimum VLT value of the electrochromic smart window that must be maintained according to each orientation of the building was derived.