• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.029 seconds

A Study of Multi-Target tracking for Radar application (레이더 응용을 위한 다중표적 추적 연구)

  • Lee Yang Weon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.2
    • /
    • pp.138-144
    • /
    • 2000
  • This paper introduced a scheme for finding an optimal association matrix that represents the relationships between the measurements and tracks in multi-target tracking of Radar system. We considered the relationships between targets and measurements as MRF and assumed a priori of the associations as a Gibbs distribution. Based on these assumptions, it was possible to reduce the MAP estimate of the association matrix to the energy minimization problem. After then, we defined an energy function over the measurement space, that may incorporate most of the important natural constraints.

  • PDF

Crystal Growth of $Cd_4SnSe_6:Co^{2+}$ Single Crystals ($Cd_4SnSe_6:Co^{2+}$ 단결정의 성장)

  • Kim, D.T.;Song, M.J.;Kim, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.607-608
    • /
    • 2005
  • In this paper, author describe the undoped and $Co^{2+}$(0.5mole%) doped $Cd_4SnSe_6$ single crystals were grown by the chemical transport reaction(CTR) method. The grown single crystals crystallize in the monoclinic structure of space group Cc and have the direct band gap structure. The energy gaps of them are 1.68 eV for $Cd_4SnSe_6$ and 1.50 eV for $Cd_4SnSe_6:Co^{2+}$ at 300K respectively.

  • PDF

Display System Design Based On The Abstraction Hierarchy

  • Sohn, Kwang-Young;Shin, Hyun-Kook
    • Nuclear Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.339-348
    • /
    • 1996
  • Plant monitoring algorithm developments seem to be saturated which means that display system to show the results from the algorithm should be the well-defined and interactive tools for operator's diagnosing, controlling, restoring the abnormal plant situations. On the other hand, very little generalized display design concepts and evaluations are available. Events that are unfamiliar to operators and that has not been anticipated by designers may cause great threats to the nuclear power plant system safety operation. The abstraction hierarchy, considered most popular display design methodology but not generalized for nuclear power plant design space, has ken proposed as a representation frame work that can be adopted to design interfaces and supports operators in diagnosing overlooked events that should have been considered to operate plant safely. However most practical plant display systems do not fully stick to this design concept but partially rely on their philosophy from design experiences. Abstraction hierarchy display design concept will be do scribed and the trend of Advanced Control Room(ACR) CRT design will also be presented with the conventional display for the several type of plants. Consequently this complementary material should be of interest to designer and regulators concerned with nuclear power plant.

  • PDF

Estimation of Joint Size Distribution Using a Contained Trace Length Distribution in a Cylindrical Window (원통형 조사창에서의 양끝내포선 길이분포를 이용한 절리크기분포 추정 연구)

  • Suh, Ga Hyun;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.26 no.3
    • /
    • pp.201-211
    • /
    • 2016
  • A method for estimating rock joint size distribution using contained traces length distribution from 3D cylindrical window survey was suggested. To reduce the numerical error, an improved technique was applied. The accuracy was verified by referring to Monte-Carlo simulation and it was found that the error can be decreased with suitable gamma values.

Digitally Controlled Interleaving Tapped-Inductor Boost Converter for Photovoltaic Module Integrated Converters (PV MIC)

  • Lee, Jye-June;Kim, Jitae;Bae, Hyunsu;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.74-75
    • /
    • 2010
  • As global warming due to burning fossil fuels and natural resource depletion issues have emerged, the development of renewable energy sources such as photovoltaics (PV) has been brought to recent interest. Amongst the vast efforts to harvest and convert solar energy into electricity, the module integrated converters (MIC) has become a worthy topic of research for grid-connected photovoltaic systems. Due to the required high-boosting qualities, only a restricted amount of DC/DC converter topologies can be applied to MICs. This paper investigates the possibility of a tapped-inductor boost converter as a candidate for PV MICs. A dual-inductor interleaving scheme operating slightly above the boundary of the two conduction modes (BCM) is suggested for reduction of input current ripple and minimization of component stress. A digital controller is used for implementation, assuring maximum power tracking and transfer while providing sufficient computational space for other grid connectivity applications, etc. For verification, a 200W converter is designed and simulated via computer software including component losses. High efficiency over a wide power range proves the feasibility of the proposed PV MIC system.

  • PDF

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

Performance Comparison of Common-Mode Voltage Reduction PWM Methods in Terms of Modulation Index (변조지수에 따른 공통모드 전압 저감 PWM 기법 성능 비교)

  • Heo, Geon;Park, Yongsoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2021
  • This study introduces a new pulse width modulation (PWM) method to reduce common-mode voltages (CMVs) and then compares its performance with other reduced CMV-PWM (RCMV-PWM) methods. CMVs should be reduced to ensure the electromagnetic compatibility and safety of grid-connected inverters. RCMV-PWM methods attempt to synthesize voltage references without zero vectors, which cause high CMV peaks. In these methods, the peak-to-peak magnitude of CMVs can be reduced by one-third of the conventional space-vector PWM. The introduced method splits every reference vector into two vectors to avoid the use of zero vectors. The performances of the RCMV-PWM methods are analyzed in accordance with the modulation index through simulation and experiment.

Constraints on scalar field models of dark energy.

  • Lee, Da-hee;Park, Chan-Gyung;Hwang, Jai-chan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.41.1-41.1
    • /
    • 2019
  • We consider dynamical dark energy models based on a minimally coupled scalar field with three different potentials: the inverse power-law, SUGRA and double exponential potentials. For each model, we derived perturbation initial conditions in the early epoch and performed the Markov Chain Monte Carlo (MCMC) analysis to explore the parameter space that is favored by the current cosmological observations like Planck CMB anisotropy, type Ia supernovae, and baryon acoustic oscillation data. The analysis has been done by using the modified CAMB/COSMOMC code in which the dynamical evolution of the scalar field perturbations are fully considered. The MCMC constraints on the cosmological as well as potential parameters are derived. In the talk we will present a progress report.

  • PDF

Falsifying LCDM: model-independent tests of the concordance model of cosmology

  • L'Huillier, Benjamin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.56.1-56.1
    • /
    • 2019
  • The concordance LCDM model has been very successful at reproducing a wide range of observations. However, the nature of its main components, such as dark energy, dark matter, and inflation, are still unkown. Therefore, it is of prime importance to question the underlying hypotheses of the model and tests there prediction. While most constraints have been obtained assuming a LCDM universe, model-independent approaches, which do not make assumptions regarding the model, are a powerful approach. To falsify the LCDM model, I applied model-indepedent methods to the latests available data to test different aspects of the concordance model, such as the FLRW metric, the curvature, dark energy as the cosmological constant, and gravity as general relativity. The Universe is consistent with flat-LCDM with GR. However, at z>1, tensions start to appear, and more data are required.

  • PDF

Analysis of Annual Operation Status of Central Heating and Cooling System in a Public Office Building (공공건물 중앙식 냉난방시스템의 연간 운영 사례 분석)

  • Ra, Seon-Jung;Aum, Tae-Yun;Son, Jin-Woong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.175-180
    • /
    • 2020
  • The purpose of this study was to clarify precautions during the design and operation phases for energy reduction in a public office building. To check the operation status of the building, we measured the indoor temperature and humidity in the office space of the building installed central heating and cooling systems. And we analyzed these data and annual BEMS data. As a result, we found six problems related to decreasing system efficiency. Based on these, we presented the information to improve the efficiency of the system from the design and operation phase. Also, we present the need for a system to support the decision-making of operational managers in real-time for the energy efficiency of the building.