• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.033 seconds

Lithium-ion Stationary Battery Capacity Sizing Formula for the Establishment of Industrial Design Standard

  • Chang, Choong-koo;Sulley, Mumuni
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2561-2567
    • /
    • 2018
  • The extension of DC battery backup time in the DC power supply system of nuclear power plants (NPPs) remains a challenge. The lead-acid battery is the most popular at present. And it is generally the most popular energy storage device. However, extension of backup time requires too much space. The lithium-ion battery has high energy density and advanced gravimetric and volumetric properties. The aim of this paper is development of the sizing formula of stationary lithium-ion batteries. The ongoing research activities and related industrial standards for stationary lithium-ion batteries are reviewed. Then, the lithium-ion battery sizing calculation formular is proposed for the establishment of industrial design standard which is essential for the design of stationary batteries of nuclear power plants. An example of calculating the lithium-ion battery capacity for a medium voltage UPS is presented.

MATHEMATICAL UNDERSTANDING OF CONSCIOUSNESS AND UNCONCIOUSNESS

  • LEE, NAMI;KIM, EUN YOUNG;SHIN, CHANGSOO
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.21 no.2
    • /
    • pp.75-79
    • /
    • 2017
  • This paper approaches the subject of consciousness and unconsciousness from a mathematical point of view. It sets up a hypothesis that when unconscious state becomes conscious state, high density energy is released. We argue that the process of transformation of unconsciousness into consciousness can be expressed using the infinite recursive Heaviside step function. We claim that differentiation of the potential of unconsciousness with respect to time is the process of being conscious in a world where only time exists, since the thinking process never have any concrete space. We try to attribute our unconsciousness to a special solution of the multi-dimensional advection partial differential equation which can be represented by the finite recursive Heaviside step function. Mathematical language explains how the infinitive neural process is perceived and understood by consciousness in a definitive time.

Flywheel Energy Storage UPS with Voltage Compensation (플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS)

  • Lee K .S.;Kim J. W.;Byeon W. Y.;Nho E. C.;Kim I. D.;Chun T. W.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.592-596
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The ups has good features such as long life-time, improved efficiency, no environment problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the operation is proved through simulations.

  • PDF

Organic Bistable Switching Memory Devices with MeH-PPV and Graphene Oxide Composite

  • Senthilkumar, V.;Kim, Yong Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.290-292
    • /
    • 2015
  • We have reported about bipolar resistive switching effect on Poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene]:Graphene oxide composite films, which are sandwiched between aluminum and indium tin oxide electrodes. In this case, I-V sweep curve showed a hysteretic behavior, which varied according to the polarity of the applied voltage bias. The device exhibited excellent switching characteristics, with the ON/OFF ratio being approximately two orders in magnitude. The device had good endurance (105 cycles without degradation) and long retention time (5 × 103 s) at room temperature. The bistable switching behavior varied according to the trapping and de-trapping of charges on GO sites; the carrier transport was described using the space-charge-limited current (SCLC) model.

Adaptive Medium Access Control protocol for low-power wireless sensor network (저전력 무선 센서 네트워크를 위한 적응적 MAC 프로토콜)

  • Kang, Jeong-Hoon;Lee, Min-Goo;Yoon, Myung-Hyun;Yoo, Jun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.209-211
    • /
    • 2005
  • This paper proposes a adaptive medium-access control(MAC) protocol designed for low-power wireless multi-hop sensor networks which is used for connecting physical world and cyber computing space. Wireless multi-hop sensor networks use battery-operated computing and sensing device. We expect sensor networks to be deployed in an ad hoc fashion, with nodes remaining inactive for long time, but becoming suddenly active when specific event is detected. These characteristics of multi-hop sensor networks and applications motivate a MAC that is different from traditional wireless MACs about power conservation scheme, such as IEEE 802.11. Proposed MAC uses a few techniques to reduce energy consumption. Result show that proposed MAC obtains more energy savings.

  • PDF

Ultrastructural Feature and Photobleaching of ginseng Chloroplasts (인삼 엽록체의 미세구조와 Photobleaching)

  • 양덕조;김명원
    • Journal of Ginseng Research
    • /
    • v.14 no.3
    • /
    • pp.416-420
    • /
    • 1990
  • Ultrastructural and anatomical features of the leaf were studied in Panax ginseng C.A. Meyer(ginseng). The ginseng leaf poorly developed palisade tissue and the size of mesophyll cell was larger and the chloroplast density was lower than that of Glycine max (soyben). Ginseng chloroplast was filled with highly stacked grana and condensely-arrayed thylakoid, so the stroma space was hardly absorbed. However, ginseng mesophyll tissue and chloroplast array did not reduce light energy entering the mesophyll chloroplast, and the high LHCP/CP ratio of ginseng thylakoid resulted in the absorption of excess photon. It is reasonable to assume that 1O1-photogenearation by excess light energy partially resulted from the anatomical and ultrastructural characteristics of the ginseng leaf.

  • PDF

The Effect of the Artificial Ground on Building Thermal Environment (인공지반이 건물 열환경에 미치는 효과에 관한 연구)

  • Hwang, Hyo-Keun;Lim, Jong-Yeon;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.170-175
    • /
    • 2009
  • Apartment housing block has been spreaded according to rapid economic development and urbanization in Korea. A parking lot is located at underground, artificial ground is inevitably created in apartment housing block. Artificial ground creates different thermal environment compared to natural ground, because the composition and coverage of artificial ground are diverse. In this study, the effect of the artificial ground on building thermal environment will be disscussed by simulation. Considering the result of simulation, surface albedo is more important for building energy performance. A purpose of this study is to examine how the characteristic of surface effect to thermal environment, and to develop design method for sustainable outdoor space.

  • PDF

Synthesis of arsenic adsorbent using graft polymerization

  • SEKO Noriaki;TAMADA Hasao
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.11a
    • /
    • pp.199-203
    • /
    • 2004
  • Fibrous arsenic (As) adsorbent was synthesized by loading zirconium (Zr) on fibrous phosphoric adsorbent that was directly synthesized by radiation-induced graft polymerization of 2-hydroxyethyl methacrylate phosphoric acid on polyethylene-coated polypropylene nonwoven fabric. Zirconium reacted with phosphoric acid grafted in the polyethylene layer. Zirconium density of the resulting adsorbent was 4.1 mmol/g. The breakthrough curve of As(V) adsorption was independent of the flow rate up to $1300\;h^{-1}$ in space velocity. The total capacity of As(V) was 2.0 mmol/g-adsorbent at pH of 2. The adsorbed Zr(IV) could be evaluated by 0.4 M sodium hydroxide solution because negligible Zr(IV) could be found in the eluted solution.

  • PDF

Improved Direct Torque Control for Sensorless Matrix Converter Drives with Constant Switching Frequency and Torque Ripple Reduction

  • Lee Kyo-Beum;Blaabjerg Frede
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.113-123
    • /
    • 2006
  • In this paper, an improved direct torque control (DTC) method for sensorless matrix converter drives is proposed which enables to minimize torque ripple, to obtain unity input power factor, and to achieve good sensorless speed-control performance in the low speed operation, while maintaining constant switching frequency and fast torque dynamics. It is possible to combine the advantages of matrix converters with the advantages of the DTC strategy using space vector modulation and a flux deadbeat controller. To overcome the phase current distortion by the non-linearity of a matrix converter drive, the simple non-linearity compensation method using PQR power theory are presented in the proposed scheme. Experimental results are shown to illustrate the feasibility of the proposed strategy.

Performance of a Time-delayed Bilateral Teleoperation: Peg-in-hole and Surface Tracking (양방향 원격 제어 성능 시험: Peg-in-hole 및 표면 추적)

  • Park, Sungjun;Park, Sangsoo;Baek, Sang-Yun;Ryu, Jeha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.789-794
    • /
    • 2014
  • This paper presents some real performance of two typical bilateral teleoperation benchmark tasks: peg-in-hole and surface tracking tasks. The tasks are performed by an energy-bounding algorithm in the master control and position-based impedance algorithm in the slave control. Performance is analyzed for the position-force tracking capabilities from free space motion to surface contacting motion. In addition, preliminary user performance is evaluated by measuring the completion time and maximum/average contact forces. The quality of the measured performance is also compared with that of other existing approaches.