• 제목/요약/키워드: energy simulation

검색결과 8,049건 처리시간 0.045초

Energy constraint control in numerical simulation of constrained dynamic system

  • 윤석준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.376-382
    • /
    • 1991
  • In the analysis of constrained holonomic systems, the Lagange multiplier method yields a system of second-order ordinary differential equations of motion and algebraic constraint equations. Conventional holonomic or nonholonomic constraints are defined as geometric constraints in this paper. Previous works concentrate on the geometric constraints. However, if the total energy of a dynamic system can be computed from the initial energy plus the time integral of the energy input rate due to external or internal forces, then the total energy can be artificially treated as a constraint. The violation of the total energy constraint due to numerical errors can be used as information to control these errors. It is a necessary condition for accurate simulation that both geometric and energy constraints be satisfied. When geometric constraint control is combined with energy constraint control, numerical simulation of a constrained dynamic system becomes more accurate. A new convenient and effective method to implement energy constraint control in numerical simulation is developed based on the geometric interpretation of the relation between constraints in the phase space. Several combinations of energy constraint control with either Baumgarte's Constraint Violation Stabilization Method (CVSM) are also addressed.

  • PDF

제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가 (Energy Performance Evaluation of A Primary School Building for Zero Energy School)

  • 윤종호;신우철;조진일;박재완;김효중;이철성
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

BIM을 활용한 에너지성능평가 기법에 관한 연구 (A Study on Evaluation Method of Energy Performance by using BIM)

  • 박승길;천정길;손원득;최현상;최영식
    • 한국산업융합학회 논문집
    • /
    • 제16권4호
    • /
    • pp.147-152
    • /
    • 2013
  • According to the obligation of BIM application, the guidelines of energy simulation based on BIM are being presented. Although there is the advantage to minimize the error in energy analysis using the energy model, there are still issues about insufficient standards and the compatibility of the gbXML. Therefore, it is necessary to establish the processes to utilize and apply BIM methods for energy simulation. This study was examined on the compatibility of data for energy simulation by the gbXML schema and energy efficiency by BIM.

표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석 (A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model)

  • 김권예;배상무;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

New Monte-Carlo based simulation program suitable for low-energy ions irradiation in pure materials

  • Ghadeer H. Al-Malkawi;Al-Montaser Bellah A. Al-Ajlony;Khaled F. Al-Shboul;Ahmed Hassanein
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1287-1299
    • /
    • 2023
  • A new Monte-Carlo-based computer program (RDS-BASIC) is developed to simulate the transport of energetic ions in pure matter. This computer program is utilizing an algorithm that uses detailed numerical solutions for the classical scattering integral for evaluating the outcomes of the binary collision processes. This approach is adopted by several prominent similar simulation programs and is known to provide results with higher accuracy compared to other approaches that use approximations to shorten the simulation time. Furthermore, RDS-BASIC simulation program contains special methods to reduce the displacement energy threshold of surface atoms. This implementation is found essential for accurate simulation results for sputtering yield in the case of very low energy ions irradiation (near sputtering energy threshold) and also successfully solve the problem of simultaneously obtaining an acceptable number of atomic displacements per incident ions. Results of our simulation for several irradiation systems are presented and compared with their respective TRIM (SRIM-2013) and the state-of-the-art SDTrimSP simulation results. Our sputtering simulation results were also compared with available experimental data. The simulation execution time for these different simulation programs has also been compared.

단지 규모 주택의 에너지 사용량 시뮬레이션 방법론에 관한 기초연구 (A Study on Simulation Methodology for Energy Consumption of Complex Unit Apartment Housings)

  • 김민환;남현진;김동호;육인수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.931-936
    • /
    • 2008
  • The need for urban-scale energy simulation is increasing as the world is aware of urgency to decrease $CO_2$ emission. As a bridge of building energy simulation and that of urban, this paper presents a case study to examine the effect of changing resolution of a model in case of complex apartment unit. Also it suggests a modeling strategy to correct differences caused by simplification of the model and evaluate the extent of its use.

  • PDF

전기자동차 에너지효율 평가를 위한 수치해석 연구 (Numerical Analysis Research for Evaluating the Energy Efficiency of Electric Vehicles)

  • 최민기
    • 한국분무공학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2024
  • This paper is a numerical analysis study for evaluating the energy efficiency of electric vehicles. Currently, the methods for testing and evaluating the energy consumption efficiency of electric vehicles have limitations such as resources and time. Therefore, there is a need for research on developing models to predict the energy consumption efficiency of electric vehicles. In this study, a numerical analysis research is conducted to predict the energy efficiency of electric vehicles using a vehicle dynamics numerical analysis model. To validate the accuracy of the simulation model, it is compared the results of dynamometer tests with the simulation results and used the Unified Diagnostic Services (UDS) protocol to acquire internal data from the electric vehicle. It is ensured the reliability of the simulation model by comparing data such as motor speed, battery voltage, current, state of charge (SOC), regenerative braking power generation, and total driving distance of the test vehicle with dynamometer test data and simulation model results.

마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가 (Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

BIM기반의 공동주택 주동 유형별 건물에너지 시뮬레이션 비교에 관한 연구 (A Comparative Study of Building Energy Simulations for Building Types in Multiple Stock Housing based on BIM(Building Information Modeling))

  • 이병호;이건원;여영호
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.87-100
    • /
    • 2010
  • The energy efficient design of the multiple stock housing is very important not only to save energy but also to increase sustainability in a whole city because the multiple stock housing type is dominated in the major residential supply markets in Korea. During the early design phase of the multiple stock housing type, the architect need convenient and accurate tools for evaluating energy consumptions based on building types rapidly. Building Information Modeling(BIM) is introduced as useful tool systems providing interoperability between 3rd dimensional modeling tools and environmental engineering analysis tools, and could reduce time and cost for unnecessary modeling works in the analysis. However, it is still hard to apply to building design practice and integrated energy simulation techniques because interoperability using industrial standard file formats such as IFC and bXML is still underdeveloped. Therefore, the purpose of this study is to perform the building energy simulations, to compare the results on typical building types in multiple stock housing based on BIM, and to clear the problems using industrial standard file formats between 3rd dimensional modeling and building energy simulation software. In addition, through comparisons with simulation results according to the typical building types such as building forms, orientations, and building stories, the interrelation ship and characteristics of BIM based building energy simulation software are analysed and evaluated.

소규모 지역냉난방 시스템 최적설계 시뮬레이션 (The Simulation Approach for the Optimal Design of Small Scale District Heating and Cooling System)

  • 임용훈;박화춘;조수;장철용;정모
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.147-154
    • /
    • 2008
  • A simulation program is developed for the optimal design of small scale district heating and cooling system. Main features for the simulation program are the reliability and the easiness for the optimal design of the DHC(District Heating and Cooling) systems. In order for implementing those features, the operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types, of which the corresponding district consist, such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features and the overall procedure of the simulation are described in brief in this paper. The results of the simulation for several test cases will be presented in subsequent study.

  • PDF