• Title/Summary/Keyword: energy saving control

Search Result 705, Processing Time 0.031 seconds

Development of BLDC Motor for HEV Engine Cooling and Battery Cooling System (하이브리드 차량의 엔진 및 배터리 냉각팬 구동용 BLDC모터 개발)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2015
  • Hybrid Electric Vehicles(HEVs) have seriously come into prevalence recently as car manufacturers and consumers have become more aware of the environmental and economic problems of conventional vehicles. For the alternative power-train and battery cooling systems in HEVs, an effective thermal management system is required, and many automakers are interested in using Brushless DC(BLDC) motors for cooling fans for the overall traction unit's performance and energy saving capability. This paper presents the development status of BLDC motors as major parts of the power-train, i.e. the engine cooling and battery cooling fans of HEVs. A design that uses BLDC motors for the power-train and each battery cooling fan, is successfully implemented through using electro-magnetic analysis, and prototype BLDC motors are examined. As experimental results, the BLDC motors achieved an efficiency of 85% as engine cooling fans and 72% as a battery thermal management fan motor. The electric cogging noise is significantly reduced by changing the skew of the slot pitch angle and optimizing the magnetic shape.

Performance assessment of apparatus for controlling algae bloom in aqua pet pank using by a cold plasma (관상어 수족관용 저온 플라즈마방식 녹조억제장치의 성능 평가)

  • Lee, Kyounghoon;Jang, Kyu-Sup;Kim, Seonghun;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.2
    • /
    • pp.126-135
    • /
    • 2013
  • This study was performed to have an effect on control the growth of algae such as "Actinastrum fluviatile" which occurs frequently in the aquaculture tank using by a cold plasma, and it also would be expected to promote the growth of water plants due to active element causing OH radicals in the water. In addition, it was verified on the death rate as 99.9% on the scale protrusion of "Aeromonas hydrophila" as well as E. coli, especially, under extreme conditions more than 100 million pathogenic bacterium in the aqua pet tank, the ornamental fish had to act in a safe and healthy environment at over 98% death rate within 48 hours. It has been proven to give no affect on aerobic bacteria that exist in the filter or soil because there was no residual toxicity in the water tank. As the results, it will help to develop and apply on the sterilization device in other industries as well as aquarium organisms due to adopted energy-saving algorithm and reliability in use.

Environmental Conservation and Sustainable Pusan Development Strategy (환경보전과 지속가능한 부산의 도시개발방안)

  • Hwang, Young-Woo;Song, Kyo-Ook;Yhang, Wii-Joo
    • Journal of Environmental Science International
    • /
    • v.6 no.3
    • /
    • pp.195-203
    • /
    • 1997
  • Pusan has experienced some different paths of urbanization and industrialization compared to other cities. and has faced the problem of over-saturation In enoronmental capacity. Pusan needs to fond out sustainable development strategies based on Agenda 21 by UNCED In 1992 to secure urban renewal. Therefore. Pusan's sustainable development strategies focus on the 1)research on envlronmental capacity and reasonable population accommodation 2)supp1y of basic enoronmental facilities for the human settlement 3)protection and efficient management of environmental pollution 4)saving and control of energy and other resources S)independent and stable euecution of plan based on biological relation 6)harmony between nature and urban spatial organization. In addition. these policies can be suggested along with the conclusions; First, ostablishment of green plan-muddle and long term environmental goals Included In the urban planning to reduce enoronmental deterioration and pollution. Second, computation of sustalnability Indeu the Index Is necessary to sustainable urban development, which is related with green GNP of the national level. Third, capacity estimation of nature and social environment-estimation of enoronmental capacity to the civilized area is required become an ecopolis, and is required to focus on the western area of Pusan which has high decree of potentiality.

  • PDF

Study on the Evaluation of Uncertainty for the Efficiency of 0.75[kW] Class Three Phase Induction Motor (0.75[kW]급 삼상유도전동기 효율의 불확도 평가에 관한 연구)

  • Jun, Hee-Deuk;Park, Han-Seok;Kim, Dea-Kyong;Woo, Kyung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.653-659
    • /
    • 2015
  • In the last few years, the regulations for efficiency grade of the three phase induction motor are internationally being discussed and upgraded for the protection of environment and energy saving. So the efficiency improvement and the reliable test result are essential to determine the premium grade three phase induction motor. While a study on developing the efficiency motor is active, there is little research about the guarantee for efficiency. So in this paper, the dispersion characteristic of the efficiency is studied using uncertainty theory for the three phase induction motor to improve the reliability of efficiency. The values such as input voltage, current, speed, torque were obtained by loss separation method to evaluate the uncertainty. From the result, it was known that the important loss factor could affect the uncertainty is the stray loss.

Development of automatic illumination controller for energy saving (에너지 절약형 자동조명 장치 개발)

  • 최명호;강형곤;김민기;한병성
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1027-1032
    • /
    • 1996
  • The auto-illumination controller for office, residence, and so on was studied. The system consists of parts of a power supply, a signal oscillator, a lamp controller and two kinds of sensor. The lamp controller has two thyristors triggered by the IR sensor(SCRI) and CdS sensor(SCR2) respectively, When the illuminance around this system is higher than operating value of its sensor, lamp is turned off automatically. Otherwise, the light of lamp gets dim by CdS sensor. In case IR sensor senses the body heat of people around itself, the illuminance of the lamp gets maximum. The illuminance of the lamp can be changed dimmly by control of the variable resistor (RV) connected with SCR2 in series. The turning - on time of the lamp can be also controlled using a variable resistor(Rt) connected with a signal oscillator in parallel. Changing resistance Rt changes the time constant(.tau.), which triggers the gate of SCR2. Though people left the surrounding of lamp, the lamp keeps light for a while.

  • PDF

Performance Analysis on Code-Division Multiple Access in Underwater Acoustic Sensor Network (수중 음향 센서 망에서의 코드 분할 다중 접속 기법에 대한 성능 해석)

  • Seo, Bo-Min;Cho, Ho-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9A
    • /
    • pp.874-881
    • /
    • 2010
  • Acoustic signal, which is a main carrier of underwater communication, attenuates along the traveled path heavily depending on the frequency as well as inter-node distance. In addition, since it has a long propagation delay, the conventional medium access control (MAC) schemes requiring complex signaling procedures and accordingly heavy overhead messages would not be appropriate in underwater communications. In this paper, we propose a code division multiple access (CDMA) scheme as a solution for MAC of underwater communication and evaluate the performance. A hierarchical data-gathering tree topology is considered and a staggered wake-up pattern is employed for the purpose of energy saving. As a performance measure, the data rate at each level of hierarchical topology is derived.

Feedback Circuit of Maximum LED Channel String Voltage Detection Converter for Energy Saving on Multichannel LED Module (Multi Channel LED 조명 Module 구동에서 최대 효율을 위한 최대 Channel 전압 감지회로)

  • Kim, Hyun-Sik;Kim, Ki-Woon;Kim, Gi-Hoon;Kim, Yu-Sin;Song, Sang-Bin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.938-941
    • /
    • 2012
  • LED is divided to multichannel in order not to exceed a certain voltage in aspects of electric standard. However, it's not possible to know in accordance with what channel SMPS controls the constant voltage and current. In order to solve this problem, it needs to detect the maximum LED String voltage which is applied to LED control circuit, and it is possible to minimize the voltage drop when a difference of LED string voltage occurs by each channel if LED is controlled by the maximum LED string voltage detected. In addition, it is also possible to maximize the efficiency of LED if change LED voltage by detecting the maximum voltage. Feasibility of this claim was verified through implementation of the circuit.

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Dynamic Shutdown at Server Power Mode Control for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 서버 전원 모드 제어에서 동적 종료)

  • Ham, Chihwan;Kim, Hoyeon;Kim, Dongjun;Kwak, Hukeun;Kwon, Huiung;Kim, Youngjong;Chung, Kyusik
    • Annual Conference of KIPS
    • /
    • 2012.04a
    • /
    • pp.79-82
    • /
    • 2012
  • 기존의 서버 전원 모드 제어에는 서버를 Off할 때 정적 종료 방식을 사용하는 관계로 서버가 사용자 요청을 모두 처리하는 최적의 종료 시간을 찾는데 시간이 많이 걸리는 단점을 가진다. 이 시간이 짧게 되면 사용자 QoS를 보장할 수 없고, 반대로 이 시간이 길게 되면 전력 절감을 기대할 수 없다. 본 논문에서는 정적 종료 방식의 단점을 극복하는 동적 종료 방식을 제안한다. 제안된 방식은 최적의 종료 시간을 찾을 필요 없이 각 서버가 사용자의 요청을 모두 처리하였을 때 자동적으로 서버를 Off한다. 제안된 방법은 최적의 시간을 자동적으로 찾아내기 때문에 사용자 QoS를 보장하고, 전력을 절감한다. 실험은 30대의 PC 클러스터를 이용하여 수행되었고, 실험을 통하여 제안하는 동적 종료 방법이 기존의 정적 종료 방법에 비해 운영자의 수고 없이 자동적으로 전력 절감 및 사용자 QoS에 기여함을 확인하였다.

An Autonomous Learning based Server Power Mode Control for Saving Energy in a Server Cluster Environment (서버 클러스터 환경에서 에너지 절약을 위한 학습기반의 서버 전원 모드 제어)

  • Ham, Chi-Hwan;Kim, Ho-Yeon;Kwak, Hu-Keun;Kwon, Hui-Ung;Kim, Young-Jong;Chung, Kyu-Sik
    • Annual Conference of KIPS
    • /
    • 2011.04a
    • /
    • pp.175-178
    • /
    • 2011
  • 서버 클러스터는 성능을 보장하기 위하여, 요청 수에 상관없이 미리 측정된 최대 부하 시점에서 처리 가능한 서버 수를 항상 운영하고 있다. 이것은 서비스의 품질은 보장할 수 있으나, 소비 전력 효율이 낮아 상당한 전력을 낭비하는 단점이 있다. 본 논문에서는 사용자 요청 수에 기반하여 동작시킬 서버의 수를 결정하는 알고리즘을 제안한다. 제안된 방식은 기존에 학습된 정보(과거 정보)와 현재의 정보에 근거하여 Off/Sleep 상태의 서버를 On 시키거나, On 상태의 서버를 Off/Sleep시켜, 현 시점에서 필요한 최적의 서버대수를 유지하도록 했다. 15대의 서버로 클러스터를 구성하고, SPECweb을 통해 실험을 수행하였다. 실험결과, 서버 모드를 제어할 경우에 제어하지 않는 경우에 비해 약 35%의 전력이 절감되고, 본 논문에서 제안하는 학습 방법을 추가로 적용할 경우 약 5%의 전력이 추가로 절감되었다.