• Title/Summary/Keyword: energy saving control

Search Result 705, Processing Time 0.027 seconds

Construction form and status analysis of intelligent type switching board of educational institution (교육기관 지능형 수배전반의 구성방식과 현황분석)

  • Choi, In-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.393-396
    • /
    • 2007
  • Recently one level higher intelligent switching board than established one by the application of intelligent building and digital system are being constructed. Therefore facility's high efficiency, high degree satisfaction, miniaturaization, standardization through application of communication technology and monitoring and controlling by computer system utilized by web-basis power control system and electric IT are practiced. Especially network must be constructed through unified IBS server that monitors every educational institute's switching boards in real time control system. And I intend to create methods to save energy and raise electricity quality by power demand prediction and remote-controled management and operation. In this thesis I intend to suggest measures of forming unified system through researching educational institute's ways of constructing switching board and status analysis and overcoming technical difficulties in user's side and saving and maintenance expense.

  • PDF

Short-term Water Demand Forecasting Algorithm Based on Kalman Filtering with Data Mining (데이터 마이닝과 칼만필터링에 기반한 단기 물 수요예측 알고리즘)

  • Choi, Gee-Seon;Shin, Gang-Wook;Lim, Sang-Heui;Chun, Myung-Geun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.10
    • /
    • pp.1056-1061
    • /
    • 2009
  • This paper proposes a short-term water demand forecasting algorithm based on kalman filtering with data mining for sustainable water supply and effective energy saving. The proposed algorithm utilizes a mining method of water supply data and a decision tree method with special days like Chuseok. And the parameters of MLAR (Multi Linear Auto Regression) model are estimated by Kalman filtering algorithm. Thus, we can achieve the practicality of the proposed forecasting algorithm through the good results applied to actual operation data.

A Study on Arc Welder of Inverter for Energy Saving in Power Station (발전소용, 인버터에 의한 절전형 아크용접기에 관한 연구)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Kim, Ki-Yong;Jung, Jae-Ruon;Kim, Chan-Ki;Lee, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.157-159
    • /
    • 1993
  • Recently, in the industrial applications, accurate arc control for welding machine are developed. This paper describes arc control of inverter-fed arc welding machine, and efficiency of inverter-fed arc welding machine. It is shown that the arc pressure and are stiffness of the pulse arc nay be as much as several times that of the equivalent dc are. Finally, the theoretical predictions are compared with test. The potential of such a welding machine is also described.

  • PDF

Demand Response Impact on Market Operator's Revenue and Load Profile of a Grid Connected with Wind Power Plants

  • Tahmasebi, Mehrdad;Pasupuleti, Jagadeesh
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • Economic properties of an integrated wind power plant (WPP) and the demand response (DR) programs in the sample electricity market are studied. Time of use (TOU) and direct load control (DLC) are two of the DR programs that are applied in the system. The influences of these methods and the incentive payments by market operator's (MOs) with variable elasticity are studied. It is observed that DR with TOU and DLC programs together yields better revenue and energy saving for MOs.

Effects of Energy Saving on Partial Heating for Pot Flower Bench Cultivation (분화류 벤치재배시 부분난방에 의한 에너지 절감 효과)

  • 김태영;우영회;조일환;김기덕;이재욱
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.04a
    • /
    • pp.44-47
    • /
    • 2002
  • 우리나라 시설재배면적은 2000년말 현재 52,189ha로 이중 가온재배 면적이 13,621ha에 다다르고 있으며 해마다 늘어나는 추세이다. 특히 연간 필요한 난방비는 약4천7백억원으로 상당한 에너지를 소비하고 있는 실정이다. 온실난방 에너지 절감을 위한 국내의 연구는 주로 보온, 난방기의 위치 및 Duct의 토출구 간격 및 직경(Kim 등, 1994), 난방배관 구조개선(Kwon 등, 1992) 지역별 난방부하 결정(Woo 등, 1998) 등을 중심으로 이루어져 왔으며 분화류와 같은 작물을 벤치재배하는데 벤치부분난방시 난방배관재의 종류 및 배관재의 간격등이 연구된바가 없으며 또한 최근 경기불황과 급격한 에너지 가격상승은 더욱 에너지 절감이 중요성을 부각시키고 있다. (중략)

  • PDF

Effects of Cokes Air Heater on Energy Saving in Horticultural Greenhouse (코크스 난방기를 활용한 시설원예 난방비 절감 효과)

  • Kim, Hyun-Hwan;Jeon, Hee;Lee, Si-Young;Kim, Jin-Young
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.04a
    • /
    • pp.115-119
    • /
    • 2002
  • 석유를 이용한 시설원예 난방이 90%를 넘고 있으며, 최근 유가의 불안정으로 시설원예 난방비 비중이 30%를 이상을 차지하고 있어 대체에너지를 이용한 난방비 절감기술이 절실하다. 현재 시설원예 면적은 약 52,189ha(채소, 화훼포함)이며, 이중 난방면적은 13,621ha로 전체 면적의 26%가 난발비의 부담을 안고 시설재배를 하고 있다. 이에 단위 열량당 연료비가 비교적 저렴한 코크스를 이용하는 난방기 중 온풍기를 개발하여 시설원예 난방비를 절감코자 본 연구를 수행하였다. (중략)

  • PDF

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF

A Method for $\frac{dv}{dt}$ suppression during switching of inverter (인버터 스위칭시 $\frac{dv}{dt}$ 억제 방법)

  • Suh, Duk-Bae;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.156-158
    • /
    • 1994
  • In recent days, the various adjustable speed drives are widely employed at the industrial applications for the purpose of energy saving and speed control. In particular, for the machine control applications. the switching frequency is required to be increased for better dynamic performance of the drive. Moreover, this also leads to the reduction of the switching loss of the device. For IGBT (Insulated Gate Bipolar Transistor), the most widely used switching device in the inverters below the 100[kW] range, the falling and falling time is of the order about $200{\sim}300[ns]$. Therefore unexpected phenomena occurs such as voltage spikes due to high gradient of current at the switching instant, the weakening of motor insulation due to high gradient of voltage. In this paper, a new voltage gradient suppression technique is presented in both theoretically and experimentally.

  • PDF

Development of energy-saving lighting system based on cooperative control of sensors (협력제어센서기반 에너지 절감형 조명시스템 개발)

  • Lee, Hyunjae;Lee, Sang-Won;Bae, SungHyun;Jeong, Jong-Hyeog;Woo, Dong Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.01a
    • /
    • pp.357-358
    • /
    • 2019
  • 본 논문에서는 조도센서와 마이크로웨이브센서 기반의 협력제어를 통하여 기존대비 35%P 전력절감이 가능한 에너지 절감형 스마트 LED 조명시스템에 대하여 기술하였다. 제안된 시스템은 센서모듈과 LED조명, 무선전송 모듈이 분리된 형태로 인지기반 조명 제어를 통하여 ESCO 사업에 적합한 에너지 절감형 융합 조명 시스템에 다양하게 활용될 수 있다.

  • PDF

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.