• Title/Summary/Keyword: energy saving control

Search Result 705, Processing Time 0.031 seconds

Energy Saving Potentials of Ventilation Controls Based on Real-time Vehicle Detection in Underground Parking Facilities

  • Cho, Hong-Jae;Park, Joon-Young;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.331-340
    • /
    • 2013
  • The main topic of this paper is to show a possibility of indoor air quality enhancement and the fan energy savings in underground parking facilities by applying the demand-controlled ventilation (DCV) strategy based on the real-time variation of the traffic load. The established ventilation rate is estimated by considering the passing distance, CO emission rate, idling time of a vehicle, and the floor area of the parking facility. However, they are hard to be integrated into the real-time DCV control. As a solution to this problem, the minimum ventilation rate per a single vehicle is derived in this research based on the actual ventilation data acquired from several existing underground parking facilities. And then its applicability to the DCV based on the real-time variation of the traffic load is verified by simulating the real-time carbon monoxide concentration variation. The energy saving potentials of the proposed DCV strategy is also checked by comparing it with those for the current underground parking facility ventilation systems found in the open literature.

A Study on Thermal Performance Evaluation with TAP (Thermosyphoning Air Panel) in Inside and Outside Insulated Constructions (TAP을 적용한 내단열과 외단열구조의 열성능 평가에 관한 연구)

  • Lee, Kyung-Hoi;Yoo, Ho-Chun;Hong, Yung-Woo;Chun, Chai-Hwi
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 1987
  • TAP system, a kind of natural convective space heating collector, has a good heat loss by night. The aim of this paper is to induce and to study an hourly heat flow theory by response factors analysis with TAP in inside and outside insulated construction, to compare and evaluate on thermal performance an hourly natural temperature, heated room temperature and heating load in aboved-mention constructions with computer simulation. The results of the study can be summarized as follows. According that there is no TAP and with TAP, it is inside insulated construction and outside insulated construction, daily natural range of temperature each shows $12.5^{\circ}C$ and $16.7^{\circ}C$, $2.7^{\circ}C$ and $3.7^{\circ}C$, daily heated range of temperature with noramal control heating system each shows $6.6^{\circ}C$ and $12.1^{\circ}C$, $1.7^{\circ}C$ and $3.1^{\circ}C$, heating hours each show 10 hr and 7 hr, 9 hr and 4 hr and heating energy saving percentage in january 123% and 79%, 100% and 40%. Therefore, energy saving percentage shows that outside insulated construction saves about 54% in comparision with inside insulated construction.

  • PDF

Analysis of the Regenerative Braking Effect to the Urban Transit Vehicles (도시철도차량의 회생제동력 분담 효과 분석)

  • Woo, Jong-Hyuk;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1900-1906
    • /
    • 2016
  • Recent energy efficiency policy of green growth for stable power supply is required. Urban transit vehicles is limited to reduce the use of power without reducing the number of runs. Accordingly, when urban rail vehicles is braking, the occurrence of regenerative power is systemically maximized for the purpose of saving energy. As a result when it is braking, the generated power efficiently is used and looking for a way to reduce the electrical energy. In this paper, the brake control system of the Subway Line 3 is analyzed the effect to meet the required regenerative braking produced electricity through minimizing air braking force of service braking.

Energy Saving System of EHP Control at the College Lecture Room (대학교 강의실 EHP 제어를 이용한 에너지 절약 시스템)

  • Jeong, Kybum
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.167-174
    • /
    • 2014
  • Heating and air conditioning system is changing rapidly from the traditional HVAC central supply system to the individual supply system with electrical heat pump system (EHP) in Korean school buildings. The individual supply system has advantages to turn on and off individually and to adjust the thermal comfort separately, but energy is wasted in the unoccupied classroom when the last leaving occupant does not turn off the controller. If the controller is to be off automatically while the classroom is not in use, energy consumption would decrease dramatically. This project aims to cease the unnecessary EHP supply in vacant classroom by inputting the class schedule from the central control room to reduce the energy-spending. Experimental measurements were carried out between the controlled classroom that is turned off when not in use and the uncontrolled room that is turned on continually. Occupant's comfort and energy consumption were measured and compared between the controlled case and the uncontrolled case. The energy consumption of controlled classroom case is 30-60% less than that of the uncontrolled classroom case. This result shows that controlling the cooling supply for the unoccupied classroom using the class schedule can decrease the energy consumption remarkably. This supply control system can be used to conserve energy in school structures like universities.

Analysis of Technology of Green IT fields using patent information (특허정보를 이용한 그린 IT 분야 기술 분석)

  • Koo, Young-Deok;Jeong, Dae-Hyun;Kwon, Young-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.2
    • /
    • pp.249-253
    • /
    • 2013
  • This study analyzed that technological competition, variety and simility of Green IT fields using patents data. To achieve this, we limited range of Green IT that reduction of energy, eco-friendly technology. Therefore we conducted analysis of patents that power saving systems, light control system, smart system, cloud computing and green house/eco systems. As the result of that, power saving field was the most developed. The simililarty of power saving and cloud computing systems are very high and similiarities of light control system, green house/eco systems and smart system were very high.

A Study on LED Control System for Object Detecting based on Zigbee Network in BEMS (BEMS용 Zigbee 네트워크 기반 객체감지형 LED 조명 제어 시스템에 관한연구)

  • Ko, Kwangseok;Lee, JungHoon;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.17-21
    • /
    • 2013
  • A building energy-saving have been increased worldwide interest. There is continuing research on IT technology for efficient management of BEMS. Recently, It is able to control of LED and to maximize energy savings to the development of LED lighting technology. We propose the security image processing system to improve efficiency and we implement the real-time status monitoring system to surveil the object in the building energy management system. In this paper, we proposed the system of LED control using Zigbee network for connect the server. User is able to control LED light and monitering by the desktop. We implemented LED light control software on the based of Real-time monitering and LED control. Also detect human body movement.

Energy Saving Type OF-LED Illuminated Display Board System with MPPT and CCVC Algorithms (MPPT 및 CCVC 알고리즘을 적용한 에너지 절약형 OF-LED 광고조명시스템)

  • Lee, Seong-Ryong;Jeon, Chil-Hwan;Lee, Su-Won;Lee, Eun-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • This paper studies the OF-LED(Optical Fiber-LED) illuminated display board system for energy saving. The OF-LED illuminated display board system has PV module, batteries, charge 8t discharge system and dynamic full color display controller. Both maximum power point tracker (MPPT) and constant current & constant voltage controls (CCVC) are used to govern the charging system. This system. improves the charging efficiency of battery. The system is compact and operates only by PV except the rainy days when the sun is unfavorable. in the system display control and charging-discharging control by on-chip microprocessor are simultaneously carried out. To verify the unposed system, me simulation and experiment results show the operating characteristics with a laboratory prototype.

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

Energy Saving Hydraulic Control System using Hydraulic Pump/Motor

  • Yongrae Cho;Bumseung Oh;Kyoungkwan Ahn;Soonyong Yang;Lee, Byungryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.66.1-66
    • /
    • 2002
  • Today it becomes a serious problem to exhaustion of a fossil fuel and air pollution by exhaust gases from road vehicles for environment preservation. To solve this problem, the developments of a hybrid vehicle have been processed for the purpose of reducing pollution and energy-savings. By the way, flywheel hybrid vehicle using variable pump/motor was proposed as one feasible hybrid system in place of hybrid vehicle system by the conventional storage battery. The proposed flywheel hybrid vehicle is composed of an accumulator or a flywheel as the energy generation and storage source and three variable hydraulic pump/motor as the energy transfer device. Flywheel has the characteristic of high...

  • PDF