• Title/Summary/Keyword: energy saving control

Search Result 705, Processing Time 0.027 seconds

A Study of the Control System for a Auto Loadsharing of the ship (선내 자동 부하분담 제어시스템에 관한 연구)

  • Lee, Hyo-Sung;Lim, Yong-Kon;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3025-3027
    • /
    • 2005
  • As the energy and manpower saving in ship have been prominent figures since oil shock, resonable operation modes of propulsion and generating plants were made a through study for the practical use. Through the results of it, advanced countries developed the load-sharing system for the generator automation and could be realized the energy and manpower saving in ship.

  • PDF

The Illumination Simulation in the Greenhouse using Daylight and Artificial Light for Energy Saving. (에너지 절감을 위한 자연광과 인공광원을 활용한 유리온실 조도 시뮬레이션)

  • Lee, Boong-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1359-1363
    • /
    • 2017
  • In this study, the Relux program was simulated for optimum conditions of daylight and artificial light sources(LED) in the glass greenhouse. From the results of daylight simulation, the optimum design conditions for the glass greenhouse were established which were 90[o] installation angle and higher transmittance. In this case of growing lettuce in the glass greenhouse, the control method of the only artificial light source was compared that of daylight and LED. The result of illumination simulation produced a power consumption effect of 37.2[%] in the summer and 51.9[%] in the winter, respectively. From this results, we propose to suggest that we grow the lettuce in the energy saving glass greenhouse.

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF

International Standardization and Implementation of Home Energy Saving System for Smart Grid (스마트 그리드를 위한 홈 에너지 절감 시스템의 IEC 국제표준화 및 구현)

  • Choi, Kwang-Soon;Lee, Sang-Won;Park, Young-Choong;Jung, Kwang-Mo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1222-1229
    • /
    • 2012
  • For the reduction of electric energy consumption and its efficient use at homes or buildings, a new work item proposal for new architecture and functional requirements of Energy Saving System (ESS) was proposed to IEC TC 100 and accepted as a new project, IEC PT 62654 in 2009. Recently, the final ballot for publication passed without negative votes and IEC TS 62654 was finally published in August 2012. For the verification of this standard, Prototype of ESS system composed of an ESS server, ESS clients, and portable ESS terminal were especially implemented in parallel with the standardization. Electric Power Control and Management (EPCM) protocol for the communication between ESS server and clients was also implemented, which supports self-configuration of ESS network, power consumption monitoring, remote power control, and additional functions for intelligent energy saving services.

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Dynamic ATIM Power Saving Mechanism(DAPSM) in 802.11 Ad-Hoc Networks (802.11 Ad-Hoc 네트웍에서 Power Save Mechanism을 개선한 DAPSM 알고리즘)

  • Park, Jae-Hyun;Lee, Jang-Su;Kim, Sung-Chun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.6
    • /
    • pp.475-480
    • /
    • 2007
  • Recently, wireless networking devices that depend on the limited Battery and power-saving of wireless hosts became important issue. Batteries can provide a finite amount of energy, therefore, to increase battery lifetime, it is important to design techniques to reduce energy consumption by wireless hosts. This paper improved power saying mechanism in Distributed Coordination Function(DCF) of IEEE 802.11. In the IEEE 802.11 power saving mechanism specified for DCF, time is divided into so-called beacon intervals. At the start of each beacon interval, each node in the power saving mode periodically wakes up during duration called the ATIM Window. The nodes are required to be synchronized to ensure that all nodes wake up at the same time. During the ATIM window, the nodes exchange control packets to determine whether they need to stay awake for the rest of the beacon interval. The size of the ATIM window has considerably affected power-saving. This paper can provide more power-saving than IEEE 802.11 power saving mode because ATIM window size is efficiently increased or decreased.

Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving (에너지 절감용 조명 및 공조기기 최적제어 시스템 개발)

  • Jang, Woo-Sung;Song, Yeoung-Seok;Cho, Byung-Lok;Cho, Seok-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1029-1036
    • /
    • 2018
  • This paper is a study on the development of optimal control system for lighting and air conditioning equipment to save the energy in campus environment. In the case of controling system developed through this research, lighting and air conditioner are controlled by both information on the number of people entering and leaving the room through the motion sensor and image processing, and the information on temperature and humidity. In addition, energy saving is enabled by the results that are controlled through data integration monitoring and command execution functions according to the control signals.

Performance Evaluation of Applied to Natural Light and Artificial Lighting Hybrid Dimming Control System (자연조명과 인공조명이 병행 적용된 하이브리드 디밍제어시스템의 성능평가)

  • Sung, Tae-Kyung;Lee, Chung-Sik;Kim, Byung-Chul;Joung, Che-Bong;Kang, Seung-Hoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.66-74
    • /
    • 2014
  • In this paper, the performance of Hybrid Dimming control system for Daylighting system is evaluated by accredited tests. The system controls the balance of illuminance of daylight between daylight system and LED light system. It makes the normal illuminance of interior without the effects of weather by controlling the LED depending on the brightness of outside. For the tests, 6 diffusers($600{\times}300mm$) were installed in lighting area($36m^2$) and normal operation of the system sensors were tested about the interference of sunlight. The results of the examinations were satisfied with the criteria of accredited tests. Further research is the verification of energy saving effect by comparing the Hybrid Dimming control system to current artificial light system.