• 제목/요약/키워드: energy recovery

검색결과 1,670건 처리시간 0.026초

CDM에서의 바이오매스 에너지 활용현황 및 전망 (The Analysis about the Status of Biomass Energy in CDM Market)

  • 명소영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.658-661
    • /
    • 2007
  • It was investigated on this paper that the status of biomass energy utilization in the registered CDM projects. The ratio of the case including the energy recovery among the registered biomass CDM projects is just about 57%. Direct thermal conversion technology is the most commonly applied for biomass energy recovery projects. Through the comparative study with world renewable energy outlook, the contribution of CDM to biomass energy supply in the world is not considerable yet.

  • PDF

Low cost energy recovery circuit for PDP using Planar Transformer networks

  • Kim, W.S.;Chae, S.Y.;Hyun, B.C.;Cho, B.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1193-1196
    • /
    • 2007
  • A new planar transformer type energy recovery circuit for PDP is proposed in this paper. The same current is transferred through both the primary and secondary sides during the energy recovery period. The conduction loss is reduced. Fabrication through simple manufacturing processes is possible using the PCB winding.

  • PDF

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

분리벽형 증류탑을 적용한 필름공정의 폐용매 회수공정 최적설계 (Optimal Design of Solvent Recovery Process with Dividing Wall Column for Film Making Process)

  • 이승현;조문신;이문용
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1209-1214
    • /
    • 2006
  • This paper presents an application of Dividing Wall Column(DWC) to the recovery of the waste solvent from the film making processes. The waste solvent feed contains MEK(Methyl-Ethyl-Ketone), Toluene, Cyclohexanone, and water. The commercial software $HYSYS^{TM}$ was used for rigorous simulation and analysis. Sensitivity analysis for several major design variables were carried out to achieve the optimal design of the process. Distribution of the internal vapor and liquid flows to the prefractionator and main sections is shown to be the most dominant design factor for energy saving efficiency in the DWC process. The simulation results also show that the solvent recovery process using the DWC significantly improves both the energy efficiency and the compactness of the solvent recovery process.

효율적(效率的)인 자원순환사회 형성을 위한 자원재활용(資源再活用) 정책 고찰(考察) (Study of the Recycling Policy to Make Efficient Resource-recycling Society)

  • 류수호
    • 자원리싸이클링
    • /
    • 제18권2호
    • /
    • pp.3-15
    • /
    • 2009
  • 녹색성장 정책의 핵심 단위 과제인 "온실가스 저감"과 "자원순환형 사회" 구축을 위해서는 폐기물 에너지회수와 물질재활용을 상호 보완적이고 균형적으로 실천하는 것이 중요하다고 할 것이다. 이에 본 연구는 과거 우리나라의 외국의 관련정책, "제4차 자원재활용 기본계획"과 "폐기물에너지화 종합대책"을 살펴보고 바람직한 자원재활용정책방향을 모색해 보았다. 그 결과 우리나라의 폐기물관리정책은 선진외국과 큰 차이가 없었으나 독일은 에너지회수를 중요하게 고려하고 고도 전처리를 의무화 하고 있는 점이 달랐으며, 우리나라의 여건은 과거보다 재찰용이 더욱 어려워질 것으로 판단되었다. "제4차 자원재활용 기본계획"에서는 필름류가 실질적이고 지속가능한 재활용이 되지 않고 있는 점을 알 수 있었으며, "폐기물에너지화" 종합대책에서는 RDF/RPF 에너지 회수가 일반소각 발전과 물질재활용에 비하여 효율성이 낮음을 알수 있었다. 이러한 문제를 해결하기 위해서는 에너지 및 폐열 회수는 에너지 회수(Recovery)로 개념 정립을 하며 전 과정평가(LCA: Life Cycle Assessment) 체계를 구축하는 등 제도적인 정비와 함께 필름류 합성수지를 용해하여 분자합성수지를 추출하는 기술 등의 기술개발도 필요함을 알수 있었다.

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

스트러트를 삽입한 원추형 디퓨져의 압력회복 특성 (Numerical Analysis of the Static Pressure Recovery Characteristics in Conical Diffuser by Inserting a Strut)

  • 김세현;서종수;심규진;이중섭;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1613-1618
    • /
    • 2004
  • Diffuser is an important fluid-mechanical equipment to convert kinetic energy into pressure energy. Many of the experimental and theoretical researches have been done in a diffuser but the understanding of energy transfer and detailed mechanism of energy dissipation is unclear. In this study, computations were performed using a numerical method with SIMPLE algorithm for conical diffuser with various diffuser angles and diffuser lengths. Also, we investigated the pressure recovery coefficient in conical diffuser by inserting strut. In this paper, we showed that the strut can cause a rising pressure recovery.

  • PDF

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.

Integrated DC-DC Converter Based Energy Recovery Sustainer Circuit for AC-PDP

  • Park, Jae-Sung;Shin, Yong-Saeng;Hong, Sung-Soo;Han, Sang-Kyoo;Roh, Chung-Wook
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.878-885
    • /
    • 2012
  • A new sustainer with primary-side integration of DC/DC converters and energy recovery(SPIDER) circuits is proposed. The proposed circuit operates as a DC-DC converter during address period and energy recovery circuit during sustain period. Therefore, the conventional three electronic circuits composed of the power supply, X-driver, and Y-driver can be reduced to one circuit. As a result, it has desirable advantages such as a simple structure, less mass, fewer devices and cost reduction. Moreover, since the Zero Voltage Switching (ZVS) of all power switches can be guaranteed, a switching loss can be considerably decreased. To confirm the operation, validity, and features of the proposed circuit, experimental results from a prototype for 42-inch PDP are presented.

Global technologies for the removal of water scaling & water recovery - Department of Energy (DOE) USA

  • Ramakrishna, Chilakala;Thriveni, Thenepalli;Whan, Ahn Ji
    • 에너지공학
    • /
    • 제27권1호
    • /
    • pp.21-32
    • /
    • 2018
  • In this paper, we reported the current technologies of water scaling removal and also water recovery from the flue gases, which are funded by Department of Energy (DOE), USA. Globally, water resources are limited due to the climate change. The potential impacts of climate change is food and water shortages. In the $21^{st}$ century, water shortages and pollution are expected to become more acute as populations grow and concentrate in cities. At present, the water stress increases over 62.0 ~ 75.8% of total water basin area and decreases over 19.7 ~ 29.0%. Many renewable energy sources demand secure water resources. Water is critical for successful climate change mitigation, as many efforts to reduce greenhouse gas emissions depend on reliable access to water resources. Water hardness is one of the major challenge to coal power plants. Department of energy (DOE) funded and encouraged for the development of advanced technologies for the removal of hardness of water (scaling) and also water recovery from the flue gases from coal power plants.