• Title/Summary/Keyword: energy ratio(efficiency)

Search Result 1,240, Processing Time 0.028 seconds

Capacity and Power Input Performance Curves Creation of Water-cooled VRF Heat Pump for EnergyPlus (EnergyPlus 해석용 수랭식 VRF 히트펌프의 냉·난방 능력 및 소비전력 예측식 산출 기법)

  • Kim, Min-Ji;Kwon, Hyuk-Joo;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Variable refrigerant flow (VRF) systems have recently attracted attention in many countries due to a variety of advantages over conventional system. Especially, the water-cooled VRF heat pump, including geothermal heat pump, is a system that accurately controls the flow rate of refrigerant for the improved efficiency under part load operation. This paper describe the process of generating the cooling and heating energy performance curve coefficients and performance expressions for modeling water cooled VRF system using EnergyPlus. Through this study, the process for generating performance curves can be implemented into EnergyPlus or other comparable building energy analysis tools for the long-term evaluation of heat pump under dynamic conditions.

A Study on the Characteristics of Refrigerating System according to the Condensation and Evaporation Load (응축 및 증발 부하에 따른 냉동시스템 특성에 관한 연구)

  • Choi, Seung-Il;Ji, Myoung-Kuk;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.44-49
    • /
    • 2013
  • The refrigerating system are high efficiency and comfortable due to the automation of the system as well as enhance energy saving are contributing to driving system. Previous study the rotational frequency of the compressor was confined to the fixed condition have changed load of evaporator and condenser related about the refrigerator performance characteristic according to the evaporation load and condensation load change tries to be analyze through the experiment. The useful data for the economic driving of the freezing apparatus tries to be drawn. Consequently, it confirmed that refrigerant in the compressor overheated and as the evaporation load increased the specific volume was increased and the coolant circulation rate decreased. In confirmed that condensation load increased the compression ratio and discharge gas temperature increased. It reduced the low-temperature efficiency and condensation calorie and the quality factor was decreased.

Experimental study on TLDs equipped with an upper mounted baffle

  • Shad, Hossein;Adnan, Azlan bin;Vafaei, Mohammadreza;Behbahani, Hamid Pesaran;Oladimeji, Abdulkareem M.
    • Smart Structures and Systems
    • /
    • v.21 no.1
    • /
    • pp.37-51
    • /
    • 2018
  • Tuned Liquid Dampers (TLDs) have gained wide acceptance as a system for structural control and energy dissipation. However, they face limitation caused by low damping in deep water, which affects their efficiency. Another problem with deep water TLDs is that not all water depth participates in energy dissipation. This paper investigated the effect of upper mounted baffles on the effectiveness of TLDs. The Vertical Blockage Ratio (VBR) of baffles ranged from 10% - 90%. The TLD (with and without baffle), structure, and combined structure with TLD (with and without baffles) were subjected to free and harmonic forced vibrations. Results indicated that baffles could significantly enhance the energy dissipation of TLDs, thus reducing structural responses more than structures equipped with ordinary TLDs. It was found that, there was an optimum value of VBR in which the TLD's efficiency was maximized. When TLD had an appropriate VBR, the structural acceleration and displacement responses were suppressed significantly up to 51% and 56%, respectively.

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System (물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구)

  • Hong, Boo-Pyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

Analysis of organic rankine cycle for designing evaporator of engine exhaust heat recovery system (엔진 배기열 회수 증발기 설계를 위한 유기랭킨사이클 분석)

  • Ko, Jea-Hyun;Choi, Byung-Chul;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.446-452
    • /
    • 2013
  • Interest in the energy efficiency and carbon reduction technology is increasing. Many studies have done on the technologies of heat recovery systems, because over 30% of the total energy is released into the atmosphere with the exhaust gas flow. In this study, the Rankine cycle is analyzed in the optimum conditions given through the previous work. The result shows that the exergy efficiency is 0.53 and the output is 1.43 kW at the condition of the pressure ratio of 0.6 and the mass flow rate of 0.7.

Experimental Study on the Characteristics of CO2 Capture with Spray Towers Using Ammonia Solution (암모니아수 흡수제를 사용하는 분무탑의 이산화탄소 포집 기본특성에 관한 실험적 연구)

  • Lim, Youngbok;Choi, Munkyoung;Lee, Jinwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.165-172
    • /
    • 2014
  • Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.

Effects of Phytase Supplementation of Diets with Two Tiers of Nutrient Specifications on Growth Performance and Protein Efficiency Ratios of Broiler Chickens

  • Selle, P.H.;Ravindran, V.;Pittolo, P.H.;Bryden, W.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.8
    • /
    • pp.1158-1164
    • /
    • 2003
  • In two feeding experiments male and mixed-sex broiler chicks were offered diets based on sorghum and a wheatsorghum blend with two tiers of nutrient specifications, without and with microbial phytase (600 and 800 FTU/kg), from 7-25 and 1-42 days post-hatch, respectively. The nutrient specifications for protein, amino acids, energy density and phosphorus (P) of standard diets were reduced to formulate the modified diets on a least-cost basis. Calculated differences in nutrient specifications between standard and modified diets ranged from 14.3 to 17.1 g/kg crude protein, 0.24 to 0.40 MJ/kg apparent metabolisable energy (AME) and 1.06 to 1.20 g/kg available P. In both experiments, reduced nutrient specifications had a negative impact on growth rates and feed efficiency and phytase supplementation had a positive influence on growth performance and protein efficiency ratios (PER). Phytase addition to the less expensive, modified diets either partially or entirely compensated for reduced growth performance and, consequently, feed costs per kg of live weight gain were reduced. In Experiment 1, phytase increased (p<0.001) nitrogen-corrected AME (AMEn) from 15.39 to 15.89 MJ/kg dry matter. For nitrogen (N) retention there was an interaction (p<0.05) between diet type and phytase as the effects of phytase on N retention were more pronounced in the modified diets, with an increase from 0.512 to 0.561. These results demonstrate the positive effects of phytase on protein and energy utilisation, in addition to its established liberation of phytate-bound P and illustrate the feasibility of assigning nutrient replacement values to the feed enzyme for consideration in least-cost ration formulations. Further work is, however, required to define the most appropriate reductions in nutrient specifications in association with phytase supplementation.

Energy Efficiency and Nutrient Deposition in Early-Weaned Pigs, according to Fat Sources Containing Different Acidic Series

  • Bosi, P.;Jung, H.J.;Han, In K.;Cacciavillani, J.A.;Casini, L.;Mattuzzi, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.7
    • /
    • pp.995-1002
    • /
    • 2000
  • To evaluate energy efficiency and partition of nutrients, 32 piglets were weaned at 14 d of age and individually fed diets containing 15% fat from coconut oil (CO, medium chain saturated), high oleate sunflower oil (HOSO, n-9 series), soybean oil (SO, n-6 series), or linseed oil plus fish oil, (LF, n-3 series). After 4 weeks, the subjects were sacrificed to evaluate empty body composition and apparent ileal digestibility with the slaughter method. No statistical effect of dietary fat sources on growth was observed. The digestibility of fat from the coconut oil diet was higher than fats from the diets containing high levels of unsaturated fatty acids. The efficiency of use of metabolizable energy for growth averaged 63% and was not affected by the diet. Dietary fat composition was reflected strongly in backfat. Total body neutral and polar fatty acids were influenced too. For the whole body phospholipid fraction the ratio of n-6 to n-3 and the double bond index were 4.3, 5.8, 7.2, 0.78 and 69, 87, 89, 87 for CO, HOSO, SO, and LF respectively. These results show that for the coconut oil diet the degree of unsaturation of phospholipids in the body was lower and that, in the other diets, it did not differ, but double bond index was maintained with different n-6 to n-3 ratios in carcass fat. On the whole the data on body fat composition indicate that the dietary fat tended to be deposited in similar quantity in the body, whatever was the dietary fatty acid profile.

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.