• 제목/요약/키워드: energy pulse

Search Result 1,308, Processing Time 0.024 seconds

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Numerical Investigation on Nonequilibrium Energy Transfer in Thin Metal Film Structures during the Irradiation of Femtosecond Pulse Laser (펨토초 레이저가 조사되는 동안의 금속 박막내의 비평형 에너지 전달 현상에 대한 수치해석 연구)

  • Sim, Hyung-Sub;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.367-373
    • /
    • 2007
  • The present study investigates numerically nonequilibrium energy transfer between electrons and phonons in metal thin films irradiated by ultrashort pulse lasers and it also provides the temporal and spatial variations of electron and phonon temperatures using the well-established two-temperature model(TTM) on the basis of the Boltzmann transport equation(BTE). This article predicts the crater shapes in gold film structures, and compares the results by using two-dimensional energy transport equation. From the results, it is found that nonequilibrium energy transfer between electrons and phonons takes place, and the equilibrium time increases with the increase of laser fluence. On the other hand, above threshold fluence the ablation time doesn't change nearly with increasing fluences. Compared with one-dimensional TTM, it also reveals that the temporal distributions of electron and phonon temperatures at the top surface estimated by using two-dimensional TTM have a similar tendency. The results show that two-dimensional TTM can simulate the crater shape of metals during the irradiation of femtosecond pulse lasers and the absorbed energy is propagated to z-direction faster than to r-direction.

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio (빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션)

  • Chung, Il-Young;Kang, Kyung-Ho;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.

The Design & Analysis of Pulse Separation Device with Thermal Barrier Type for Dual Pulse Rocket Motor (이중펄스 로켓모타의 격막형 펄스분리장치 설계 및 성능평가)

  • Kim, Jinyong;Kwon, Taeha;Lee, Wonbok;Cho, Wonman;Lee, Bangeop;Jung, Gyoodong;Rhee, Youngwoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.93-99
    • /
    • 2015
  • The dual pulse rocket motor(DPRM) distributes the propellant energy effectively via pulse separation device(PSD) to improve the range and terminal velocity of the missile. There are two types of PSD such as bulk head type and thermal barrier type. A subscale thermal barrier type DPRM was designed, manufactured, and tested. The results showed good understanding of the characteristics of the PSD and will be applied to the design of the full scale DPRM.

A Study on the Removal Characteristics of microbe and metal-oxide using pulse discharging (펄스방전을 이용한 미생물제거 및 금속산화물 제거특성에 관한 연구)

  • Joung, Jong-Han;Kim, Su-Won;Kim, Hwi-Young;Lee, U-Soo;Jeon, Jin-An;Jung, Hyun-Ju;Kim, Hee-Je;Song, Woo-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1818-1820
    • /
    • 2003
  • In this study, we developed friendly-environment device through various applications of pulse power system and studied research about pulse energy transfer characteristics. We have studied the mutual relation between characteristics of the load impedance and consumed power of the pulse power system. The consumed power means electrical power from the wall plug. For changing the load impedance, we could change elecrode length. As results, we can get electrical characteristics between pulse generator and load. When the pulse energy was triggered the microbes, caused waste water, they were almost removed in the waste water.

  • PDF

Effects of the Irradiated Current Mode PWM Controller of DC/DC Power Converter (DC/DC 전력 컨버터의 전류모드 PWM 제어기의 방사선 영향)

  • Lho, Young-Hwan;Hwang, Eui-Sung;Lho, Kyeoung-Su;Phouphanonh, Phouphanonh;Khamphoungeun, Khamphoungeun;Han, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.685-692
    • /
    • 2011
  • DC/DC switching power converters produce DC output voltages from different DC input sources. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The current mode DC/DC converter is composed of a PWM (pulse width modulation) controller, a MOSFET, and inductor, etc. Pulse width modulation is applied to control and regulate the total output voltage. It is shown that the variation of threshold voltage at MOSFET and the offset voltage increase caused by radiation effects make the PWM pulse unstable. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by simulation program with integrated circuit emphasis (SPICE) and experiments.

  • PDF

Output Characteristics of a Flashlamp pumped Nd:YAG Lasers at 1.444 nm (플래시 램프로 펌핑한 Nd:YAG 레이저의 $1.444{\mu}m$ 출력 특성)

  • Lee, Hee-Chul;Kim, Gyu-Ug;Kim, Dong-Hyun;Gong, Sung-Hwan;Kim, Yong-Pyung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.606-610
    • /
    • 2006
  • We investigated the output characteristics of Nd:YAG lasers at wavelength of 1444 nm, which were pumped by 450 Xe-flashlamp, 700 torr Xe-flashlamp and 700 torr Kr-flashlamp. With a Xe-flashlamp of 700 torr of gas pressure, the pulse energy of 0.738 J was obtained with repetition rate of 9.16 Hz and pumping pulse width of 400 ms. In case pumping pulse width of 5 ms and repetition rate of 1 Hz, 700 torr Kr-flashlamp showed the highest pulse energy of 1.44 J.

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF