• Title/Summary/Keyword: energy performance evaluation

Search Result 1,874, Processing Time 0.035 seconds

Evaluation on Thermal Energy Performance of a Plate Heat Exchanger (판형열교환기의 열에너지 성능평가)

  • Kang, Byung-Ha;Kim, Do-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • Performance evaluation on thermal transport of a plate heat exchanger has been carried out. The $\varepsilon$-Ntu method is employed to evaluate the performance of a brazed type of plate heat exchanger. This problem is of particular interest in the design of a plate heat exchanger. The characteristics of heat transfer as well as pressure drop are studied in the wide range of Reynolds numbers in the cold side while that of hot side is fixed at 620. f-factor correlation in a plate heat exchanger is obtained from the pressure drop data. It is also found that the effectiveness of the plate heat exchanger is increased as the Ntu is increased.

Performance Evaluation of SiC Honeycomb Modules Used for Open Volumetric Solar Receivers (개방형 체적식 흡수기를 위한 SiC 허니컴 모듈의 성능 평가)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Kim, Jong-Kyu;Yoon, Hwan-Ki;Lee, Sang-Nam;Han, In-Sub;Seo, Doo-Won
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.120-125
    • /
    • 2012
  • Daegu Solar Power Tower Plant of a 200 kW thermal capacity uses an open air receiver. An air receiver is generally based on the volumetric receiver concept with porous ceramic absorbers. Because absorber material is important in the volumetric receiver, ceramic materials with excellent thermal conductivity, high solar absorptivity and good thermal stability have been researched. KIER also developed SiC honeycomb absorber modules and evaluated performance of the modules at the KIER solar furnace. For performance evaluation, we made an open volumetric receiver containing the modules and measured the outlet temperature and the efficiency. It is demonstrated that performance of the KIER absorber is comparable to that of a reference absorber developed by DLR.

  • PDF

Performance Evaluation Method of Grid-Connected PV System (계통연계형 PV시스템의 성능특성 평가방법)

  • So, Jung-Hun;Yu, Byung-Gyu;Jung, Young-Seok;Hwang, Hye-Mi;Yu, Gwon-Jong;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1245-1246
    • /
    • 2007
  • In present, as the various PV system have been installed and disseminated, research and development of photovoltaic(PV) system is the most important issues to establish usefulness of design, installation, supervision and maintenance of PV system with performance improvement. This paper presents evaluation and analysis method for estimating performance and losses of PV system and components using monitoring data.

  • PDF

Performance Evaluation of the Wall-Type BIPV System Based on the Energy Consumption Unit - A Study for University Lecture Building - (에너지 소비 원단위를 기초로 한 벽면부착형 BIPV 시스템의 성능평가에 관한 연구 - 대학교 강의동 건축물을 대상으로 -)

  • Lee, Kang-Guk;Seo, Won-Duck;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.25-32
    • /
    • 2011
  • The building integrated photovoltaic(BIPV) system has a double advantage that it reduces costs for exterior materials and PV panels. It allows the construction of a low-energy building without the need for the additional installation space. At the construction planning stage, however, it requires sufficient evaluation on the efficiency and performance. This study was performed to promote the distribution of photovoltaic power generation system by estimating the potential photovoltaic power generation capacity of the BIPV system installed on the university lecture building and by evaluating the characteristics and performances of window, spandrel and combined attachment types via the simulation of generation capacity per unit area.

  • PDF

PERFORMANCE EVALUATION OF NEW SPACER GRID SHAPES FOR PWRS

  • Song, Kee-Nam;Lee, Soo-Bum;Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.737-746
    • /
    • 2007
  • A spacer grid, which is one of the most important structural components in a PWR fuel assembly, supports its fuel rods laterally and vertically. Based on in-house design experience, scrutiny of the design features of advanced nuclear fuels and the patents of other spacer grids, KAERI has devised its own spacer grid shapes and acquired patents. In this study, a performance evaluation of KAERI's spacer grid shapes was carried out from mechanical/structural and thermohydraulic view points. A comparative performance evaluation of commercial spacer grid shapes was also carried out. The comparisons addressed the spring characteristics, fuel rod vibration characteristics, fretting wear resistance, impact strength characteristics, CHF enhancement, and the pressure drop level of the spacer grid shapes. The results show that the performances of KAERI's spacer grid shapes are as good as or better than those of the commercial spacer grid shapes.

A Simulation Appraisal of Energy Performance in Office Building by Different Types of Air-Conditioning (공조방식에 따른 사무소 건물의 에너지 성능 평가)

  • Choi, Jong-Dae;Choi, Dong-Suk;Yun, Geun-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.612-620
    • /
    • 2012
  • High economic growth causes increase of the building energy consumption. The energy consumption for HVAC system accounts for 40~50% of the whole building consumption. The trend for building is large-scale and high-rise. Because of the trend, the energy consumption is becoming bigger than before. Nowadays, HVAC system design are recognized as the solution for a energy-saving. This paper is focused on the energy performance evaluation of central air-conditioning system(water-based) and system air-conditioning that were applied to the office building. The systems are modeled and simulated by using EnergyPlus Software 6.0. After the Simulation, annual cooling and heating energy consumption were calculated. It was found that the system air-conditioning can reduce the energy consumption approximately 55.24% annually compared with the central air-conditioning system(water-cooled). In addition, about 46.13% of annual operating costs can be reduced by use of system air-conditioning.

Performance Monitoring Results, Evaluation and Analysis of 50kW Grid-Connected PV System (50kW급 계통연계형 태양광발전시스템의 성능모니터링 결과 및 평가분석)

  • So, Jung-Hun;Yu, Byung-Gyu;Hwang, Hye-MI;Yu, Gwon-Jong;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.29-35
    • /
    • 2007
  • Monitoring system is constructed for evaluating and analyzing performance of installed 50kW grid-connected PV system and have been monitored since October 2005. As climatic and irradiation conditions have been varied through long-term operation, there is necessity for evaluating numerical values of PV(Photovoltaic) system performance to observe the overall effect of environmental conditions on their operation characteristics. This paper presents performance monitoring results and analysis on component perspective(PV array and power conditioning system) and global perspective(yield, losses) of PV system for one year monitoring periods.

Research on Lighting Performance Evaluation for Different Curvature Reflection Rate in Residential Space (주거공간 내 광선반 곡률 형태에 따른 채광성능평가 연구)

  • Oh, Sangwon;Lee, Heangwoo;Kim, Yongseong;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.328-336
    • /
    • 2015
  • Currently, 22% of the total energy consumption of buildings in Korea is used for lighting. Light-shelves have garnered attention as a way to reduce consumption, but there are few studies on the types of curve and curvature, which limits the improvement of light-shelf performance and its design. This study constructed a test bed of actual residential types to evaluate the performance. Outcomes of light usage, according to variables of light-shelves, were used as indicators of performance evaluation. The results are as follows:1) Performance evaluation was conducted on flat-type light-shelves to verify performance of curvature-shelves, which are movable with a width of 200 mm, and the most ideal angle and specification per solar term are calculated. 2) The (-) shaped curvature contributed to a reduction in energy consumption and an improvement of evenness. 3) In case of light-shelves with (-) shaped curvature, an increased angle not exceeding $80^{\circ}$ of the arc contributed to an improvement of light penetration. 4) Appropriate specifications of curved light-shelves include movable types with widths of 200 mm, and angle ranges of $20^{\circ}{\sim}60^{\circ}$. 5) Light energy consumption of a movable light-shelf with curvature and width of 200 mm were reduced by 17% and 7.8% compared to a $0^{\circ}$ fixed and a movable light-shelf, respectively.