• Title/Summary/Keyword: energy performance evaluation

Search Result 1,880, Processing Time 0.029 seconds

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

Energy Consumption Characteristics and Evaluation of Thermal Insulation Performance in Accordance with Built Year of Apartment Complex (공동주택의 준공연도에 따른 단열성능 평가 및 에너지소비 특성에 관한 연구)

  • Choi, Doo Sung;Lee, Myung Eun;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.79-86
    • /
    • 2014
  • Studies have shown that the thermal performance of buildings changes depending on the year of construction completion. It leads to increased energy consumption of buildings and significant financial burden on users. Thus, this study has calculated the thermal insulation performance of 86 apartments quantitatively, using temperature difference ratio and sensible heat flux. Also, energy consumption characteristics depending on the year of construction completion and thermal insulation performance were analyzed by comparatively analyzing the results of insulation performance evaluation and heating costs. The analysis results are as follows. As for thermal insulation performance, it was around 70% lower in the apartments completed before 1985, compared to apartments completed after 2010. As for heating costs, the apartments with the highest heating cost incurred 1.5 higher heating cost than the apartment with the lowest heating cost. In terms of the insulation performance evaluation, the difference was 2.5-fold.

Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump (직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Woo, Joung-Son;Baik, Young-Jin;Jang, Jea-Chul;Kim, Ji-Young;Ra, Ho-Sang
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

The Study to Suggest a Methods to Evaluate Heating and Cooling Energy Performance based on Daily Life (실생활기반 냉난방에너지 성능평가 방법 제안 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Kim, Yongseong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.5 no.3
    • /
    • pp.291-299
    • /
    • 2015
  • With recent surge of attention to heating and air conditioning energy consumption, the need for evaluating performance of heating and air conditioning energy is also on the rise. This research aims to propose daily-life based evaluation method as an alternative to existing one, as well as to apply the method in real life to prove its validity. The results are as following. 1) I studied temperatures preferred by persons indoors and appropriate level of temperature, and the results show that properties of such persons such as age is directly linked with pleasantness of the room, but the issue lies with the fact that such properties are not considered in existing performance evaluation of heating and air conditioning. 2) Daily life based evaluation proposed herein reflects such properties of persons indoors. It controls heating / air conditioning devices installed in the test bed with the same size as a real life room to get quantitative and visual performances in our daily life as well as simple temperature information. 3) To verify validity of daily life based evaluation, I conducted different evaluation sessions with and without a blind and also based on ages of persons indoors. Results based on properties of persons showed difference of 77.6%, leading to effective analysis of energy consumption pattern by heating / air conditioning devices. This research takes significance in that it comes with a new performance evaluation method based on real life, and I gather that further studies are required to develop more multilateral performance evaluation in order to verify and improve technology for reduction of energy consumption.

Performance Evaluation and Technical Development of Eco-environmental Photovoltaic Leisure Ship with Sail-controlling Device With Respect to Solar-Hybrid Generating System (풍력 Sail 돛 제어장치를 이용한 친환경 태양광 레져보트의 하이브리드 발전시스템 관련 성능평가에 대한 연구)

  • Oh, Kyoung Gun;Moon, Byung Young;Lee, Ki Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2016
  • As a new technical approach, an attempt was made to realize a photovoltaic system for an eco-environmental leisure ship by simultaneously actuating nine photovoltaic solar panels in association with the application of a sail-controlling system using wind energy. In this approach, the photovoltaic system consisted of a solar module, an inverter, a battery, and the relevant components, while the sail-controlling device was equipped with sail up/down and mast turning systems. The previously mentioned eco-environmental leisure ship utilizes a photovoltaic hybrid system that uses solar and wind energy as renewable energy sources. Furthermore, this research included a performance evaluation of the manufactured prototype, the acquisition of the purposed quantity values, and development of the purposed items. The significant items, including the sail up/down speed (seconds) and mast turning angle (degrees) were evaluated for a performance test. A wind direction sensitivity of 90% and maximum instant charging power of 900 W were also obtained in the process of the performance evaluation. In addition, the maximum sail time was also evaluated in order to acquire the optimum value. The performance evaluation showed that the prototype with a photovoltaic hybrid system was suitable for sailing an eco-environmental leisure ship using solar and wind energy.

Study on performance evaluation of a francis turbine (프란시스 수차의 성능평가에 관한 연구)

  • Ko, Jaemyoung;Kim, Youngjoon;Cho, Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.207.1-207.1
    • /
    • 2011
  • The performance of a francis turbine is studied by applying a new performance evaluation tester. the performance of a francis turbine is predicted under several operating conditions and the prediction results are compared with model test data. As a result, it is demonstrated that the present method can predict the performance of a francis turbine with high accuracy and has usefullness as an engineering tool on the performance of hydraulic turbines.

  • PDF

A Study on the Evaluation of Building Energy Rating considering the Insulation performance of the Window in Apartment houses (공동주택에서의 창호성능에 따른 건물에너지 효율등급 평가 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Sung-Hee;Jang, Cheol-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.291-295
    • /
    • 2009
  • As a reasonable energy policy has become required because of consuming substantial amounts of oil than others, the studies on energy consumption are in work for energy savings of buildings that spend up to 24% of total energy consumption. However, there aren't basic data on energy consumption and installationregulations for effective equipments in energy guzzled buildings. The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. Thus, we should prepare the alternatives to improve insulation performance of envelopes and the efficiency of insulation performance of the window for reducing energy consumption.

  • PDF

Study on Application and Economic Evaluation of New Insulation Material to Confront High Oil Price: Focus on an Apartment (고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로)

  • Hyun, Jong-Hun;Kim, Ji-Yeon;Park, Hyo-soon;Choi, Moo-Hyuck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.746-751
    • /
    • 2008
  • The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case 1, 2) and vacuum or triple glazing can retrieves the investment with $120 and $140$\sim$150 per barrel each.

A Study on the Performance Evaluation of Variable-speed Drive Pump (가변속펌프의 성능평가방법에 관한 연구)

  • Suh, Sang-Ho;Kim, Hyoung-Ho;Rakibuzzaman, Rakibuzzaman;Kim, Kyung-Wuk;Yoon, In-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.83-88
    • /
    • 2014
  • Pumps are widely used in industrial plants, energy systems, ships etc. Generally they consume nearly 20% each nation's total electrical energy. The objective of this study is to find performance evaluating method for variable-speed drive pump. In order to evaluate the variable-speed pump performance energy saving rate for the variable-speed pump is applied and compared with that of constant-speed pump.