Evaluation of New Design Concepts for Steam Generators in Sodium Cooled Liquid Metal Reactors

  • Kim, Seong-O.;Sim Yoonsub;Kim, Eui-kwang.;Myung-Hwan.Wi;Han, Dohee.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.121-132
    • /
    • 2003
  • To reduce the construction cost and enhance the safety of sodium cooled liquid metal reactors, various kinds of new design concepts were evaluated using the KALIMER operation condition. The required equipment sizes were set for plant electricity output to be similar to that of KALIMER. The evaluations were made focusing on the plant performance and implementation practicality. Each design concept was evaluated for the concept itself and design impacts to interfacing systems. Through the evaluation of the concepts, it was found that the most favorable design concept is the integrated steam generator with forced convection using lead bismuth as the intermediate heat transfer fluid between the primary sodium tube and feed water/steam tube in the steam generator.

Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses (구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Lee, Cheol-Hee;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

Validity Evaluation of Scale Model Experiments in Architectural Daylighting Performance (자연채광 성능평가에 있어서 축소모형실험 방법론의 유용성 검증에 관한 연구)

  • Kim, J.T.;Chung, Y.G.;Jeong, I.Y.;Hwang, M.K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Daylighting is a powerful vehicle of architectural expression and provides buildings a living quality due to constantly changing properties in intensity and color. As an environmental system, daylighting should be subjected to the same level of rigorous analysis and review that any environmental system receives. For example, increasing cooling loads and causing visual displeasure are easily occurred owing to the excessive sunlight through windows. Therefore, daylighting performance attributes and physical characteristics must be described qualitatively and quantitatively in early design process. In various architectural daylighting performance evaluation methods, the scale model experiment can be applied due to it's simplicity and usefulness. So, this study aims to evaluate the validation of scale model experiments in architectural daylighting performance. For the purpose, two scale model experiments under clear sky are conducted. And, the validation of the experiments are evaluated by computer simulations.

Study on the Performance Evaluation and Supplementations of Extracorporeal Shockwave Therapy (체외충격파 치료기(Extracorporeal Shockwave Therapy)의 성능평가 및 보완사항에 관한 연구)

  • Oh, Chan-Woo;Park, Sang-Geon;Park, Hong-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.52-56
    • /
    • 2018
  • Extracorporeal shockwave therapy has been widely spread out showing an excellent efficacy compared to traditional medicinal treatments, interventional procedures or surgeries for diseases of tendons and musculoskeletal system. Major performance tests of extracorporeal shockwave therapy consist of pressure, energy flux, concentration, and effective amount of energy on the focus area of shockwave according to IEC 61846. Shockwave should be irradiated accurately to the lesion area to improve the performance of extracorporeal shockwave therapy, which makes it necessary to add the relevant section, IEC 60601-2-36 (12.1.101. Precision of Target Markers and Target Locations). International standards of extracorporeal shockwave therapy have been prepared based on European and western people. Thus, we need to conduct many studies on Korean patients to improve the quality of extracorporeal shockwave therapy and to develop the medical industry. In addition, the performance evaluation of extracorporeal shockwave therapy which has been prepared according to international standards should be additionally modified and supplemented corresponding to the Korean circumstances.

(PMU (Performance Monitoring Unit)-Based Dynamic XIP(eXecute In Place) Technique for Embedded Systems) (내장형 시스템을 위한 PMU (Performance Monitoring Unit) 기반 동적 XIP (eXecute In Place) 기법)

  • Kim, Dohun;Park, Chanik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.3
    • /
    • pp.158-166
    • /
    • 2008
  • These days, mobile embedded systems adopt flash memory capable of XIP feature since they can reduce memory usage, power consumption, and software load time. XIP provides direct access to ROM and flash memory for processors. However, using XIP incurs unnecessary degradation of applications' performance because direct access to ROM and flash memory shows more delay than that to main memory. In this paper, we propose a memory management framework, dynamic XIP, which can resolve the performance degradation of using XIP. Using a constrained RAM cache, dynamic XIP can dynamically change XIP region according to page access pattern to reduce performance degradation in execution time or energy consumption resulting from native XIP problem. The proposed framework consists of a page profiler gathering applications' memory access pattern using PMU and an XIP manager deciding that a page is accessed whether in main memory or in flash memory. The proposed framework is implemented and evaluated in Linux kernel. Our evaluation shows that our framework can reduce execution time at most 25% and energy consumption at most 22% compared with using XIP-only case adopted in general mobile embedded systems. Moreover, the evaluation shows that in execution time and energy consumption, our modified LRU algorithm with code page filters can reduce more than at most 90% and 80% respectively compared with applying just existing LRU algorithm to dynamic XIP.

  • PDF

Performance Evaluation of Energy Management Algorithms for MapReduce System (MapReduce 시스템을 위한 에너지 관리 알고리즘의 성능평가)

  • Kim, Min-Ki;Cho, Haengrae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 2014
  • Analyzing large scale data has become an important activity for many organizations. Since MapReduce is a promising tool for processing the massive data sets, there are increasing studies to evaluate the performance of various algorithms related to MapReduce. In this paper, we first develop a simulation framework that includes MapReduce workload model, data center model, and the model of data access pattern. Then we propose two algorithms that can reduce the energy consumption of MapReduce systems. Using the simulation framework, we evaluate the performance of the proposed algorithms under different application characteristics and configurations of data centers.

An Evaluation of High Performance Sunlighting Mirror Systems (고성능 태양광 채광시스템의 채광성능평가)

  • Kim, J.T.;Hwang, M.K.;Chung, Y.G.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.49-59
    • /
    • 2002
  • Recently, due to high rise building by rapid urbanization, the spaces incapable of being penetrated by sunlight into interior is increasing. So, sunlighting systems are important means to be able to get sunlight into indoors and to make sure of sunshine awareness. This study aims to evaluate lighting performance of sunlighting mirror systems. As results. these are very useful for the increase of an average illuminance of indoors and the penetration of sunlight. Especially, the second reflecting mirrors can be applied to spaces lack of sunlight. And these sunlighting systems developed in the present study is validated physical and psychological performance to both building and people.

Design and Performance Evaluation of a 10kW Scale Counter-Rotating Tidal Turbine (10kW급 상반전 조류터빈의 설계와 성능에 관한 연구)

  • Hoang, Anh Dung;Yang, Chang-Jo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • This paper aims to present the design and performance evaluation of a counter-rotating tidal turbine using CFD and to compare its performance with single rotor. The device scale is 10kW and the rotating part consists of two rotors which rotate in opposite direction. Compared with conventional single rotor, the counter-rotating system shows higher power efficiency at high stream velocity but lower efficiency at low stream velocity. The added counter-rotated rotor together helps improve the energy absorption capacity but has influence on the upstream rotor that reduces its performance. In terms of power capture, the designed counter-rotating tidal turbine is more advantageous in high speed tidal condition.

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

Public Building Value Evaluation Using Contingent Valuation Method Based on Market Value Estimation

  • PARK, Jieun;YU, Jungho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.367-370
    • /
    • 2015
  • Building deterioration reflects the degradation of basic building performance including structural performance, energy performance, durability, and safety, and it also includes perceived deterioration, which considers a user-based perspective. More than 50% of the existing buildings in Korea are over 15 years old and public buildings compose 2.5% of all buildings domestically. Therefore, there are several different problems, such as poor energy efficiency, structural performance, and safety. To address the challenges of increasing stock in deteriorated buildings, it is necessary to make decisions about reconstruction or renovation. In this study, we propose a new method to evaluate public building value with a contingent valuation method (CVM). By estimating willing-to-pay (WTP) from users of private buildings in similar situation with the public building, it is possible to compare market prices and calculate a correction factor to adjust the WTP data. Finally, we apply the correction factor to the WTP of a public building and estimate market price, willingness to pay (WTP). Finally, we apply the correction factor to willing to pay (WTP) of public building and estimate market price.

  • PDF