• 제목/요약/키워드: energy input

검색결과 2,474건 처리시간 0.025초

An Input-Powered High-Efficiency Interface Circuit with Zero Standby Power in Energy Harvesting Systems

  • Li, Yani;Zhu, Zhangming;Yang, Yintang;Zhang, Chaolin
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1131-1138
    • /
    • 2015
  • This study presents an input-powered high-efficiency interface circuit for energy harvesting systems, and introduces a zero standby power design to reduce power consumption significantly while removing the external power supply. This interface circuit is composed of two stages. The first stage voltage doubler uses a positive feedback control loop to improve considerably the conversion speed and efficiency, and boost the output voltage. The second stage active diode adopts a common-grid operational amplifier (op-amp) to remove the influence of offset voltage in the traditional comparator, which eliminates leakage current and broadens bandwidth with low power consumption. The system supplies itself with the harvested energy, which enables it to enter the zero standby mode near the zero crossing points of the input current. Thereafter, high system efficiency and stability are achieved, which saves power consumption. The validity and feasibility of this design is verified by the simulation results based on the 65 nm CMOS process. The minimum input voltage is down to 0.3 V, the maximum voltage efficiency is 99.6% with a DC output current of 75.6 μA, the maximum power efficiency is 98.2% with a DC output current of 40.4 μA, and the maximum output power is 60.48 μW. The power loss of the entire interface circuit is only 18.65 μW, among which, the op-amp consumes only 2.65 μW.

Estimation of Input Material Accounting Uncertainty With Double-Stage Homogenization in Pyroprocessing

  • Lee, Chaehun;Kim, Bong Young;Won, Byung-Hee;Seo, Hee;Park, Se-Hwan
    • 방사성폐기물학회지
    • /
    • 제20권1호
    • /
    • pp.23-32
    • /
    • 2022
  • Pyroprocessing is a promising technology for managing spent nuclear fuel. The nuclear material accounting of feed material is a challenging issue in safeguarding pyroprocessing facilities. The input material in pyroprocessing is in a solid-state, unlike the solution state in an input accountability tank used in conventional wet-type reprocessing. To reduce the uncertainty of the input material accounting, a double-stage homogenization process is proposed in considering the process throughput, remote controllability, and remote maintenance of an engineering-scale pyroprocessing facility. This study tests two types of mixing equipment in the proposed double-stage homogenization process using surrogate materials. The expected heterogeneity and accounting uncertainty of Pu are calculated based on the surrogate test results. The heterogeneity of Pu was 0.584% obtained from Pressurized Water Reactor (PWR) spent fuel of 59 WGd/tU when the relative standard deviation of the mass ratio, tested from the surrogate powder, is 1%. The uncertainty of the Pu accounting can be lower than 1% when the uncertainty of the spent fuel mass charged into the first mixers is 2%, and the uncertainty of the first sampling mass is 5%.

Input-Series-Output-Parallel Connected DC/DC Converter for a Photovoltaic PCS with High Efficiency under a Wide Load Range

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.9-13
    • /
    • 2010
  • This paper proposes an input-series-output-parallel connected ZVS full bridge converter with interleaved control for photovoltaic power conditioning systems (PV PCS). The input-series connection enables a fully modular power-system architecture, where low voltage and standard power modules can be connected in any combination at the input and/or at the output, to realize any given specifications. Further, the input-series connection enables the use of low-voltage MOSFETs that are optimized for a very low RDSON, thus, resulting in lower conduction losses. The system costs decrease due to the reduced current, and the volumes of the output filters due to the interleaving technique. A topology for a photovoltaic (PV) dc/dc converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing the PV module characteristics is proposed. The control scheme, consisting of an output voltage loop, a current loop and input voltage balancing loops, is proposed to achieve input voltage sharing and output current sharing. The total PV system is implemented for a 10-kW PV power conditioning system (PCS). This system has a dc/dc converter with a 3.6-kW power rating. It is only one-third of the total PV PCS power. A 3.6-kW prototype PV dc/dc converter is introduced to experimentally verify the proposed topology. In addition, experimental results show that the proposed topology exhibits good performance.

비선형 에너지 추적기를 이용한 근접된 톤 신호 검출 (Detection of narrowly spaced tone signals using a nonlinear energy tracker)

  • 황성수;이용환
    • 한국통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.2470-2476
    • /
    • 1997
  • We propose a simle scheme for detecting tone signals narrowly spaced in the frequency by employing a nonlinear device called Teager's energy tracker. When the input signal is a tone signal, the output of Teager's energy tracker is proportional to the energy and tone frequency of the input signal. When the envelope of the input tone is varying, this tracker can also track the energy of the envelope. By employing Teager's algorithm as a preprocessor, the detector for narrowly spaced tone signals can be implemented without the use of sharp notch filters. As an example, the proposed detector is applied to distinguishing ITU-T V.8 and V.25 tone signals. The detector perfodrmance is analyszed and is verified by computer simulation.

  • PDF

열가소성 폴리우레탄과 벅-부스트 컨버터를 이용한 마이크로 에너지 포집시스템 설계 (Design of Micro Energy Harvesting System using Thermoplastic Polyurethane and Buck-boost Converter)

  • 손영대;김규현
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.560-565
    • /
    • 2011
  • This paper proposes the design of micro energy harvesting system by using thermoplastic polyurethane(TPU), which harvests electric energy from the kinetic energy of pedestrian and drives the desired load, and applied it to the self-generating shoes. Also, we designed the buck-boost converter in discontinuous conduction mode(DCM) which functions as a resistor emulator(RE) such that converter's average input current is proportional to input voltage, and it results in transfer of maximum power to buck-boost converter according to control behavior that converter's input resistance is matched with TPU's internal resistance. Therefore, this paper confirms the validity of proposed control scheme and possibility of application for self-generating shoes, from the obtained characteristic of designed micro energy harvesting system by using a TPU and buck-boost converter in DCM.

Parametric study on energy demands for steel special concentrically braced frames

  • Dogru, Selcuk;Aksar, Bora;Akbas, Bulent;Shen, Jay
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.265-276
    • /
    • 2017
  • Structures are designed in such a way that they behave in a nonlinear manner when subject to strong ground motions. Energy concepts have been widely used to evaluate the structural performance for the last few decades. Energy based design can be expressed as the balance of energy input and the energy dissipation capacity of the structure. New research is needed for multi degree of freedom systems (MDOFs)-real structures- within the framework of the energy based design methodology. In this paper, energy parameters are evaluated for low-, medium- and high-rise steel special concentrically braced frames (SCBFs) in terms of total energy input and hysteretic energy. Nonlinear dynamic time history analyses are carried out to assess the variation of energy terms along the height of the frames. A seismic energy demand spectrum is developed and hysteretic energy distributions within the frames are presented.

기질 농도에 따른 미생물전기분해전지의 운전 특성 (Effect of substrate concentration on the operating characteristics of microbial electrolysis cells)

  • 서휘진;김재일;기서진;안용태
    • 유기물자원화
    • /
    • 제31권4호
    • /
    • pp.41-49
    • /
    • 2023
  • 본 연구는 주입 기질 농도에 따른 미생물전기분해전지 (Microbial electrolysis cell, MEC)의 운전성능을 조사하였다. 주입 기질 농도에 따른 MEC의 운전 성능을 비교하기 위해 6 개의 실험실 규모 MEC를 2, 4, 6 g/L Sodium acetate 조건으로 순서대로 주입 농도를 증가시켜 운전하였다. 전류밀도, 수소 생산량, SCOD 제거율을 분석하였고, 에너지 효율, cathodic hydrogen recovery를 계산하여 주입 기질 농도 별 MEC의 운전성능을 비교하였다. 체적 전류밀도는 4 g/L 조건에서 76.3 A/m3였고, 6 g/L로 주입 농도를 증가시켰을 때 19.0 A/m3로 4 g/L 주입 조건에 비해 75% 감소하였다. 수소 생산량은 4 g/L 주입 조건이 47.3 ± 16.8 mL로 가장 높았으나 수소 수율은 2 g/L 주입 조건이 1.1 L H2/g CODin로 가장 높았다. 에너지 효율 역시 2 g/L 조건에서 가장 높았고, 6 g/L 조건에서 가장 낮은 결과를 보여주었다. 최대 전기에너지 효율은 76.4%였으며, 2 g/L 조건에서 최대 전체에너지 효율은 39.7%였다. 그러나 기질 농도가 6 g/L로 증가하였을 때, 성능이 급격히 감소하였다. Cathodic hydrogen recovery 역시 에너지 효율과 유사한 경향을 보였으며, 가장 낮은 농도 조건에서 가장 높은 성능을 보여주었다. 따라서 MEC 운전에 있어서 SCOD 제거율뿐만 아니라 에너지 효율 등을 고려한 최적 운전을 위해서는 낮은 주입 농도 조건에서 운전하는 것이 바람직할 것으로 판단된다.

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

HSB600강 용접에서 입열량, 보호가스, 용접후 열처리가 미세조직과 기계적 특성에 미치는 영향 (The effect of Heat input, Shielding Gas(Ar80% + $CO_2$20%), PWHT on the mechanical properties of HSB600 steel Weldments)

  • 주동휘;임영민;김남훈;고진현
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 2부
    • /
    • pp.394-397
    • /
    • 2011
  • The effects of heat input(1.4~3.2kJ/mm), shielding gas(Ar80%+$CO_2$20%) and postweld heat treatment(PWHT, $600^{\circ}C$, 40hr.) on the TMCP HSB600 steel weldments made by GMAW process were investigated. The tensile strength and CVN impact energy of as-welded specimens decreased with increasing heat input. The fine-grained acicular ferrite was mainly formed in the low heat input while polygonal and side plate ferrites were dominated in the high inputs. High performance steel for bridges requires higher performance in tensile and yield strength, toughness, weldability, etc. Thus, the purpose of the experiment is to study HSB 600 in GMAW.

  • PDF

산업연관표 2009를 이용한 태양광발전설비산업의 생산유발효과분석 (Induced Production Analysis for Photovoltaic Power Generation Equipment in Korea using Input-Output Table 2009)

  • 김윤경
    • 신재생에너지
    • /
    • 제8권1호
    • /
    • pp.8-17
    • /
    • 2012
  • The Korean government pushed ahead various policies to disseminate photovoltaic (PV), wind power, small hydro, bio-fuel, etc. Renewable energy system (RES) budget of the Korean government increased from 118 billion won of 2003 to 876.6 billion won of 2010. The R&D budgetary supports for RES increased by 6.8 times in the period 2003-2010. It is necessary to confirm RES budget expenditure that renewable energy promotion policy makes good performance evaluated in quantity level. This paper made Input-Output Table 2009 contains photovoltaic power generation equipment industry as a dependent sector and analyzed induced production effect by demand of photovoltaic power generation equipment industry. From the empirical analysis result, additional demand in photovoltaic power generation equipment induced 1.932 times of induced production in Korea. Each of industry sector has positive induced production from the additional demand in photovoltaic power generation equipment. Renewable energy promotion in photovoltaic power generation is considered together with industry policy as the option to sustain economic growth.