• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.028 seconds

Performance Comparison of a Welded Plate Heat Exchanger and Shell and Tube Heat Exchanger with Same Heat Transfer Area (동일 전열면적을 갖는 용접식 판형열교환기와 관류형 열교환기의 성능 비교)

  • Ham, Jeonggyun;Kim, Min-Jun;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.46-54
    • /
    • 2019
  • In this study, the performance of a shell and tube heat exchanger (STHE) and welded plate heat exchanger (WPHE) was measured experimentally. The pass numbers of the STHE was changed by 1, 2 and 4. As a result, the WPHE showed 2.1 times higher heat exchange capacity than that of the STHE. In case of pressure drop, the STHE with 1 and 2 pass number has a lower pressure drop than the WPHE, while the STHE with 4 pass presented higher pressure drop than the WPHE. The performance index considering the heat exchange capacity and pump consumption power, showed in oder of STHEPass1 > STHEPass2 > W PHE > STHEPass4 under the same flow rate. Therefore, when the WPHE was designed optimally under same operating condition with STHE, the maintenance fee and space can be reduced effectively by using the WPHE.

Structure-Control Combined Design with Structure Intensity

  • Park, Jung-Hyen;Kim, Soon-Ho
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.60-68
    • /
    • 2003
  • This paper proposes an optimum design method of structural and control systems, using a 2-D truss structure as an example. The structure is subjected to initial static loads and disturbances. For the structure, a FEM model is formed. Using modal transformation, the equation of motion is transformed into modal coordinates, in order to decrease D.O.F. of the FEM model. To suppress the effect of the disturbances, the structure is controlled by an output feedback $H_{\infty}$ controller. The design variables of the combined optimal design of the control-structure systems are the cross sectional areas of truss members. The structural objective function is the structural weight. The control objective function is the $H_{\infty}$ norm, the performance index of control. The second structural objective function is the energy of the response related to the initial state, which is derived from the time integration of the quadratic form of the state in the closed-loop system. In a numerical example, simulations have been perform. Through the consideration of structural weight and $H_{\infty}$ norm, an advantage of the combined optimum design of structural and control systems is shown. Moreover, since the performance index of control is almost nearly optimiz, we can acquire better design of structural strength.

  • PDF

Non linear analysis of a functionally graded square plate with two smart layers as sensor and actuator under normal pressure

  • Arefi, M.;Rahimi, G.H.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.433-447
    • /
    • 2011
  • The present paper addresses the nonlinear response of a FG square plate with two smart layers as a sensor and actuator under pressure. Geometric nonlinearity was considered in the strain-displacement relation based on the Von-Karman assumption. All the mechanical and electrical properties except Poisson's ratio can vary continuously along the thickness of the plate based on a power function. Electric potential was assumed as a quadratic function along the thickness direction and trigonometric function along the planar coordinate. By evaluating the mechanical and electrical energy, the total energy equation can be minimized with respect to amplitude of displacements and electrical potential. The effect of non homogenous index was investigated on the responses of the system. Obtained results indicate that with increasing the non homogenous index, the displacements and electric potential tend to an asymptotic value. Displacements and electric potential can be presented in terms of planar coordinate system. A linear analysis was employed and then the achieved results are compared with those results that are obtained using the nonlinear analysis. The effect of the geometric nonlinearity is investigated by using the comparison between the linear and nonlinear results. Displacement-load and potential-load curves verified the necessity of a nonlinear analysis rather than a linear analysis. Improvement of the previous results (by the linear analysis) through employing a nonlinear analysis can be presented as novelty of this study.

Effect of Environmental and Physiological Factors on Bone Mineral Density in Postmenopausal Women (폐경후 여성의 골밀도에 대한 환경, 생리적 요인의 영향)

  • 이보경
    • Journal of Nutrition and Health
    • /
    • v.25 no.7
    • /
    • pp.656-667
    • /
    • 1992
  • This study was designed to investigate the effect of environmental an d physiological factors on bone mineral density(BMD) of the lumbar spine(L2longrightarrowL4) in 41 postmenopausal women. There were a positive relationships between BMD of the lumbar spine and monthly income food expenses pocket money energy expenditure(EXP) per day sociocultural EXP activity intensity time of standing and walking or age at first pregnancy. BMD of the lumbar spine was negatively correlated with age Engel index time of sleeping and sitting number of childbirty and children period of breastfeeding or menopausal period. But there were no significant relationships between BMD and physiological domestic EXP body mass index age at menar-che menstruation cycle or age at menopause. The complex interrelations between BMD and these variables were examined using stepwise multiple regression analysis. From this analysis in subject aged 50~59 years. EXP per body weight physiological EXP age at menopause time of sleeping were positively significant independent predictors of BMD. In subjects aged 60~69 years, . time of walking only and in total subjects. EXP per body weight pocket money were positively significant independent predictors ofBMD. This study suggest that EXP and pocket money are major constituents affection lumbar spine BMD in postmenopausal women.

  • PDF

Consideration on the Prediction Approach of Ash Deposition Propensity in Coal-fired Boilers (석탄 보일러에서 회분 부착성향 예측 접근 방법에 대한 고찰)

  • Kim, Daehee;Choi, Sangmin;Kim, Jung-Rae
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.27-34
    • /
    • 2017
  • Various approaches have been proposed to predict the ash deposition (slagging and fouling) propensity of coal, which is essential in maintaining high efficiency and preventing corrosion/damage of a coal-fired boiler. The common method is to establish an index of the ash deposition propensity based on elementary coal composition and advanced characterization of ash properties, which is readily applicable to design, operation and maintenance of coal-fired boilers. Although many indexes have been developed for this purpose, their validity is still not satisfactory in actual applications to particular coal types or operating conditions. This paper reviews the status of predictive approaches for the ash deposition propensity, and assesses the performance of existing indexes by comparing the results for selected coals. This work will contribute to the development of a comprehensive and practical method for prediction of the ash deposition propensity.

Evaluation anisotropy in stochastic texture images using wavelet transforms for characterizing printing, coating and paper structure

  • Sung, Yong-Joo;Farnood, Ramin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2005.11a
    • /
    • pp.45-53
    • /
    • 2005
  • A novel method for evaluating the anisotropy of the deterministic features in a stochastic 2D data is introduced. The ability of the wavelet transform for the identification of the abrupt discontinuities could be used to characterize the boundary of the deterministic area in a 2D stochastic data, such as flocs in paper structure. The one-dimensional wavelet transform with a small-scale range in MD and CD could quantify the amount of the edge in both directions, depending on the intensity of each floc. The flocs that are aligned in the MD direction result in a higher value of local wavelet energy in the CD direction. Therefore, the ratio of the total wavelet energy in CD and MD directions can be used as a new anisotropy index. This index is a measure of the floc-orientation and can provide an excellent tool to obtain the orientation distribution and the major oriented angle of flocs. Various simulated images and real stochastic data such as local gloss variation of printed image and formation image, have been tested and the results show this analysis method is very reliable to measure the anisotropy of the deterministic features.

  • PDF

A Design Criterion for the Vibration Isolation of a Marine Diesel Generator Set (선박용 디젤발전기의 진동 절연을 위한 설계 기준)

  • Brennan M.J.;Mace B.R.;Lee, D.C.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.329-338
    • /
    • 2006
  • The resilient mounts of a diesel engine installed onboard a ship should be designed for both static and dynamic loads. If possible, the resonance frequencies of the six rigid body modes of the installation and the flexible modes of the engine support structure should not lie within the engine operation range. In this paper a design criterion is proposed to evaluate an isolation system which involves the summation of dynamic forces transmitted through the resilient mounts and elastic potential energy index stored in the mounts. A case study is also presented in which a diesel engine generator, which had an elastic foundation and was mounted in a 5500 TEU container vessel, was studied both theoretically and experimentally. The theoretical analysis of the test model was performed by using a single mass 6 degree of freedom system. Actual measurements of mechanical vibration of the engine and its foundation onboard were carried out, which showed the importance of including the flexibility of the engine support structure in the mode.

Development of Tracking Daylighting System Using Multi-Parabolic Reflector (다중 파라볼릭 반사경 방식을 이용한 추적식 집광시스템 개발)

  • Lee, Chung-Sik;Kim, Jong-Min;Park, Yeon-Min;Sung, Tae-Kyung;Joung, Che-Bong;Kang, Seung-Hoon;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.56-63
    • /
    • 2013
  • Daylighting system is an alternative lighting system using daylight collecting device, light transformer and light diffuser. In this paper, we developed a daylighting system in which the collecting device composed by dual parabolic reflectors, the silica optical fiber adapted to the light transformer and light diffuser made of the polyglass square sheet. We have estimated the system efficiency and general color rendering index(Ra) of the developed system. The system efficiency measured to 23.8% and Ra was revealed as 95. Ra number of the developed system is bigger than the number(65) of the previous fresnel lens based sunlight collector.

Thermal Kinetics of Color Changes of Purple Sweet Potato Anthocyanin Pigment (자색고구마 Anthocyanin 색소의 가열에 대한 속도론적 연구)

  • Lee, Lan-Sook;Rhim, Jong-Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.497-501
    • /
    • 1997
  • Kinetic parameters on heat-induced color changes of anthocyanin pigment from purple sweet potato were determined in the temperature range of $121{\sim}141^{\circ}C$. Color change determined by a browning index $(A_{532}\;nm/A_{420}\;nm)$ followed second order reaction kinetics. Activation energy values of purple sweet potato pigment solutions of pH 2.0, 3.0, 4.0 and 5.0 were 69.57, 76.68, 81.07 and 92.98 kJ/mol, respectively, indicating that temperature dependency of the reaction increased with pH. Apparent kinetic compensation effect between preex-ponential factor and activation energy value was observed.

  • PDF

Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer (수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Kim, Gi-Hyun;Im, Jin-Soon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF