• Title/Summary/Keyword: energy index

Search Result 2,329, Processing Time 0.036 seconds

A Study on Nutrient Intake and Food Consumption by Food Frequency Questionnaire According to the Obesity Index of Women College Students in Kunsan. (군산시 일부 여대생의 비만도에 따른 영양소 섭취와 식품섭취빈도)

  • 장혜순;김미라
    • Korean Journal of Human Ecology
    • /
    • v.6 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • The purpose of this study was to compare nutrient intake and food consumption by food frequency according to the obesity index of women college student in Kunsan. The subjects were 251 women college students who were randomly selected from Kunsan national university. Subjects were assigned to one of the following group based on BMI : underweight, normal weight and overweight. Nutrient intake and food consumption by food frequency were evaluated based on questionnaires and 24 hour recall method. The results were as follows. %RDA of calcium, iron and zinc of obese group were more than the underweight group(p<0.05). %Fat was significantly correlated with the daily intakes of protein and vitamin E(p<0.05). %Fat was significantly correlated with %RDA of energy, protein, vitamin E, vitamin B$_{6}$. RBW was significantly correlated with %RDA of iron. BMI was significantly correlated with %RDA of energy, calcium, phosphorus. The foods frequently consumed among students were cooked rice and gimchi. The frequencies of fish and mushroom were correlated with food behavior scores(p<0.01). The frequencies of carbonated beverage(p<0.01), hamburger & piazza, deep fried foods(p<0.01), soybean curd fried fish cake(p(0.05) were correlated with nutritional knowledge scores.

  • PDF

Numerical Analysis on the Performance Improvement of Plate Heat Exchanger by Applying to CuO Nanofluid (CuO 나노유체를 적용한 판형열교환기 성능에 대한 수치해석적 연구)

  • Ham, Jeonggyun;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • In this study, a numerical study was conducted to evaluate the performance improvement when CuO nanofluid was used in the plate heat exchanger. As a result, the heat transfer amount is increased by 5.45% when 2 vol% CuO nanofluid is used. The influence on the CuO nanofluid on the performance of heat exchanger is decreased by increasing the flow rate of working fluid. In addition, the overall heat transfer coefficient using 2 vol% CuO nanofluid decreased compared to the base fluid. However, the pressure drop and the consumption of the pump power is increased as the concentration of CuO nanofluid increased because the increase of the viscosity. These are increased up to 15.4% compared to those of the base fluid. Moreover, the performance index of CuO nanofluid is decreased by 12.6% compared to that of the base fluid.

Structure-Control Combined Design with Structure Intensity

  • PARK JUNG-HYEN;KIM SOON HO
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.57-65
    • /
    • 2003
  • This paper proposes an optimum design method of structural and control systems, using a 2-D truss structure as an example. The structure is subjected to initial static loads and disturbances. For the structure, a FEM model is formed. Using modal transformation, the equation of motion is transformed into modal coordinates, in order to decrease D.O.F. of the FEM model. To suppress the effect of the disturbances, the structure is controlled by an output feedback $H_{\infty}$ controller. The design variables of the combined optimal design of the control-structure systems are the cross sectional areas of truss members. The structural objective function is the structural weight. The control objective function is the $H_{\infty}$ norm, the performance index of control. The second structural objective function is the energy of the response related to the initial state, which is derived from the time integration of the quadratic form of the state in the closed-loop system. In a numerical example, simulations have been perform. Through the consideration of structural weight and $H_{\infty}$ norm, an advantage of the combined optimum design of structural and control systems is shown. Moreover, since the performance index of control is almost nearly optimiz, we can acquire better design of structural strength.

The Difference of EEI through the Slope of Stairs (계단 높이에 따른 에너지소모지수(EEI)의 변화)

  • Lee, Jung-Rim;Ahn, Duck-Hyun;Kim, Yu-Mi
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.67-76
    • /
    • 1999
  • Going up and down the stairs is a repeated task in the activities of daily living. These activities are needed during the recovery process with impaired lower limbs. This paper presents the difference of EEI (energy expenditure index) through the slope of stairs. Twenty-one normal young adults took a part in this study (11 males, 10 females). They stepped up and down the stairs which had two different slopes for 5 minutes. Resting heart rate, walking heart rate, and moving distance were recorded. EEI was calculated from the heart rate and moving speed which was calculated by the distance of movement. Data were analyzed by repeated two-way ANOVA with SAS program and the difference of EEI through the slope of stairs was not statistically significant (p=0.9971). The results show that EEI was not affected by the slope of stairs in normal people. But distance of movement (p=0.0067) and speed (p=0.0064) had a significant difference.

  • PDF

A study on APR-1400 core design for heterogeneous thorium fuel (APR-1400 원전을 위한 비균질 토륨핵연료 노심설계 방안연구)

  • 배강목;김관희;김명현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.135-141
    • /
    • 2002
  • An optimization of KTF thorium fuel assembly design was performed on the basis of the design parameter studies. Optimization goals ware to make the core have both proliferation resistance and fuel cycle economics. Four kinds of proliferation resistance indexes were used; SNS, TG, BCM, Toxicity. A new index, FEI was regarded as a limiting index for the maximization of fuel cycle economics. Optimized thorium fuel design was applied for APR-1400 reactor core. Nuclear core design procedures were examined to solve the thorium fuel reactor problems. It was shown that heterogeneous thorium fuel core option is acceptable in safety and economics aspects.

  • PDF

A Design Criterion for the Vibration of a Marine Diesel Generator Set (선박용 디젤발전기의 진동 절연을 위한 설계 기준)

  • Lee, D.C.;Brennan, M.J.;Mace, B.R.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.648-655
    • /
    • 2005
  • The resilient mounts of a diesel engine installed onboard a ship should be designed for both static and dynamic loads. If possible, the resonance frequencies of the six rigid body modes of the installation and the flexible modes of the engine support structure should not lie within the engine operation range. In this paper a design criterion is proposed to evaluate an isolation system which involves the summation of dynamic forces transmitted through the resilient mounts and elastic potential energy index stored in the mounts. A case study is also presented in which a diesel engine generator, which had an elastic foundation and was mounted in a 5500 TEU container vessel, was studied both theoretically and experimentally. The theoretical analysis of the test model was performed by using a single mass 6 degree of freedom system. Actual measurements of mechanical vibration of the Engine and its foundation onboard were carried out, which showed the importance of including the flexibility of the engine support structure in the mode

  • PDF

Dietary Compliance among Men Participating in a Controlled feeding Study of fiber Supplementation

  • Yoon, Hei-Ryeo
    • Journal of Nutrition and Health
    • /
    • v.31 no.5
    • /
    • pp.957-964
    • /
    • 1998
  • The study was undertaken to assess the degree to which subjects were compliant with a specific metabolic diet in a controlled outpatient feeding study. The study consisted of a two-week control period in which subjects consumed a control diet consisting of 38-40% fat, 18-20% protein, 40-42% carbohydrate, followed by a three-week experimental period during which each subject consumed the control diet plus one of the four fiber supplements(20g/4ay) assigned on a random basis on the trust day. All meals were prepared and eaten in a metabolic feeding laboratory, with the exception of Saturday and Sunday meals that were packed for take-out. Fifty-seven healthy adult men, aged 18-65 years participated in the study. Dietary compliance index(CI) defined as the percent deviation of actual consumption from the prescribed food's and unconsumed prepared foods. The CI reflected the additional 'non-prescribed foods' and unconsumed 'prescribed foods'. A CI was calculated for all subjects. A CI of 5% or more was defined as poor compliance. Overall, dietary compliance was substantially improved for the entire group over the course of the study. Significant increase in compliance far energy and macronutrient intake occurred between the baseline and experimental periods. Within a non-obese group, dietary compliance fir energy improved from 5.5% to 3.3% by the end of the study(week 1vs week 5, respectively, p<0.05). However, between non-obese and obese group, dietary compliance was not different. (Korean J Nutrition 31(5) : 957-964, 1998)

  • PDF

Evaluation of Reliability and Interruption Cost of Distribution Power System in Industrial Complex (산업단지내 배전계통의 공급신뢰도 및 정전비용 평가)

  • Choi, Sang-Bong;Nam, Ki-Young;Kim, Dae-Kyeong;Jeong, Seong-Hwan;Rhoo, Hee-Seok;Lee, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.95-96
    • /
    • 2006
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate distribution power system reliability by using customer interruption costs. Accordingly, it is increased for methodology to evaluate distribution power system reliability in power supply zones under competitive electricity market. This paper presents algorithm to evaluate system average interruption duration index. expected energy not supplied and system outage cost taking Into consideration failure rate of distribution facility and industrial customer interruption cost. Also, to apply this algorithm to evaluate system outage cost presented in this paper, distribution system of a dual supply system consisting of mostly high voltage customers in industrial complex in Korea is used as a sample case study. Finally, evaluation results of system interruption cost, system average interruption duration index and expected energy not supplied in sample industrial complex area are shown in detail.

  • PDF

Sustainability Evaluation of Western Nakdong River Basin by the Systems Ecology (시스템 생태학적 접근법에 의한 서낙동강 유역의 지속성 평가)

  • Kim, Jin Lee;Park, Bae Kyung;Lee, Su Woong;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.439-445
    • /
    • 2010
  • An emergy analysis of the main energy flows driving the economy of humans and life support systems consists of environmental energies, fuels, and imports, all expressed as solar emjoules. Total emergy use (371 E20 sej/yr) of the Western Nakdong River Basin is 97 per cent from imported sources, fuels and goods and services. Emergy flows from the environment such as rain and geological uplift flux accounted for only 2.9 percent of total emergy use. Emergy yield ratio and environment loading ratio were 1.03 and 33.27, respectively. Emergy sustainability index, a ratio of emergy yield ratio to environment loading ratio, is therefore less than one, which is indicative of highly developed consumer oriented economies. It is necessary for an efficient management of Western Nakdong River Basin to reduce pollution load basically and to restructure economic activities into an environmental friendly industrial structure depending on renewable energy and resources.

Damage Detection in a Beam Structure Using Modal Strain Energy (빔 구조물의 모달 변형에너지를 이용한 손상탐지)

  • 박수용;최상현
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.333-342
    • /
    • 2003
  • The objective of this paper is to present an algorithm to locate and size damage in a beam structure. The method uses the changes in the modal strain energy distribution. A damage index, utilized to identify possible location and corresponding severity of local damage, is formulated and expressed in terms of modal displacements that can be obtained from mode shapes of the undamaged and the damaged structures. The possible damage locations in the structure arc determined by the application of damage indicator according to previously developed decision rules. The robustness and effectiveness of the method arc demonstrated using numerical examples of beam structures with simulated damage.