• Title/Summary/Keyword: energy dissipated

Search Result 315, Processing Time 0.034 seconds

Experimental evaluation of steel connections with horizontal slit dampers

  • Lor, Hossein Akbari;Izadinia, Mohsen;Memarzadeh, Parham
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.79-90
    • /
    • 2019
  • This study introduces new connections that connect the beam to the column with slit dampers. Plastic deformations and damages concentrate on slit dampers. The slit dampers prevent plastic damages of column, beam, welds and panel zone and act as fuses. The slit dampers were prepared with IPE profiles that had some holes in the webs. In this paper, two experimental specimens were made. In first specimen (SDC1), just one slit damper connected the beam to the column and one IPE profile with no holes connected the bottom flange of the beam to the column. The second specimen (SDC2) had two similar dampers which connected the top and bottom flange of the beam to the column. Cyclic loading was applied on Specimens. The cyclic displacements conditions continued until 0.06 radian rotation of connection. The experimental observations showed that the bending moment of specimen SDC2 increased until 0.04 story drift. In specimen SDC1, the bending moment decreases after 0.03 story drift. Test results indicate the high performance of the proposed connection. Based on the results, the specimen with two slit damper (SDC2) has higher seismic performance and dissipates more energy in loading process than specimen SDC1. Theoretical formulas were extended for the proposed connections. Numerical studies have been done by ABAQUS software. The theoretical and numerical results had good agreements with the experimental data. Based on the experimental and numerical investigations, the high ductility of connection is obtained from plastic damages of slit dampers. The most flexural moment of specimen SDC1 occurred at 3% story drift and this value was 1.4 times the plastic moment of the beam section. This parameter for SDC2 was 1.73 times the plastic moment of the beam section and occurred at 4% story drift. The dissipated energy ratio of SDC2 to SDC1 is equal to 1.51.

Chlorophyll a Fluorescence Parameters of Hulled and Hull-less Barley (Hordeum vulgare L.) DH Lines Inoculated with Fusarium culmorum

  • Warzecha, Tomasz;Skrzypek, Edyta;Adamski, Tadeusz;Surma, Maria;Kaczmarek, Zygmunt;Sutkowska, Agnieszka
    • The Plant Pathology Journal
    • /
    • v.35 no.2
    • /
    • pp.112-124
    • /
    • 2019
  • Barley worldwide is affected seriously by Fusarium seedling blight (FSB) and Fusarium head blight (FHB) diseases caused by the Fusarium species. The objective of this study was to facilitate the resistance of hulled and hull-less barley at different growth stages to F. culmorum according to direct parameters: disease rating (DR), fresh weight of leaves and roots, kernel weight per spike, kernel number per spike, plump kernels, and indirect parameters - chlorophyll a fluorescence (CF). Plate assay, greenhouse and field tests were performed on 30 spring barley doubled haploid (DH) lines and their parents infected with Fusarium culmorum. Direct parameters proved that hulled genotypes show less symptoms. Most studied chlorophyll a fluorescence (CF) parameters (apart from DIo/CS - amount of energy dissipated from PSII for laboratory test, TRo/CS - amount of excitation energy trapped in PSII reaction centers, ETo/CS - amount of energy used for electron transport and RC/CS - number of active reaction centres in the state of fully reduced PSII reaction center in field experiment) were significantly affected by F. culmorum infection. In all experiments, hulled genotypes had higher values of CF parameters compared to hull-less ones. Significant correlations were detected between direct and indirect parameters and also between various environments. It was revealed that ABS/CS, TRo/CS, and RC/CS have significant positive correlation in greenhouse test and field experiment. Significant correlations suggest the possibility of applying the CF parameters in selection of barley DH lines resistant to F. culmorum infection.

Seismic response and energy dissipation in partially restrained and fully restrained steel frames: An analytical study

  • Reyes-Salazar, Alfredo;Haldar, Achintya
    • Steel and Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.459-480
    • /
    • 2001
  • The damage suffered by steel structures during the Northridge (1994) and Kobe (1995) earthquakes indicates that the fully restrained (FR) connections in steel frames did not behave as expected. Consequently, researchers began studying other possibilities, including making the connections more flexible, to reduce the risk of damage from seismic loading. Recent experimental and analytical investigations pointed out that the seismic response of steel frames with partially restrained (PR) connections might be superior to that of similar frames with FR connections since the energy dissipation at PR connections could be significant. This beneficial effect has not yet been fully quantified analytically. Thus, the dissipation of energy at PR connections needs to be considered in analytical evaluations, in addition to the dissipation of energy due to viscous damping and at plastic hinges (if they form). An algorithm is developed and verified by the authors to estimate the nonlinear time-domain dynamic response of steel frames with PR connections. The verified algorithm is then used to quantify the major sources of energy dissipation and their effect on the overall structural response in terms of the maximum base shear and the maximum top displacement. The results indicate that the dissipation of energy at PR connections is comparable to that dissipated by viscous damping and at plastic hinges. In general, the maximum total base shear significantly increases with an increase in the connection stiffness. On the other hand, the maximum top lateral displacement $U_{max}$ does not always increase as the connection stiffness decreases. Energy dissipation is considerably influenced by the stiffness of a connection, defined in terms of the T ratio, i.e., the ratio of the moment the connection would have to carry according to beam line theory (Disque 1964) and the fixed end moment of the girder. A connection with a T ratio of at least 0.9 is considered to be fully restrained. The energy dissipation behavior may be quite different for a frame with FR connections with a T ratio of 1.0 compared to when the T ratio is 0.9. Thus, for nonlinear seismic analysis, a T ratio of at least 0.9 should not be considered to be an FR connection. The study quantitatively confirms the general observations made in experimental results for frames with PR connections. Proper consideration of the PR connection stiffness and other dynamic properties are essential to predict dynamic behavior, no matter how difficult the analysis procedure becomes. Any simplified approach may need to be calibrated using this type of detailed analytical study.

A Performance Analysis of Embedded Systems adapting Data Prefetching (데이터 선인출을 채용한 임베디드 시스템의 성능 분석)

  • Moon, Hyun-Ju;Yoo, Hyun-Bae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.148-155
    • /
    • 2006
  • Portable embedded systems which mainly handle multimedia applications involve the problem that frequent accesses to fetch data from memory make running time increased. To cope with the problem, embedded processors have adopted data prefetching schemes. From a power point of view, which is a main performance indicator of embedded systems, this paper analyzed to investigate how data prefetching schemes influence on system's performance. To solve the problem, we proposed a power-consumption analysis model of a memory system with data prefetching scheme and measured the power dissipated during running application programs. As a result data prefetching schemes have application program's running time reduced but have system's power increased. Also we proposed a performance analysis model considering execution time and power consumption for embedded system with data prefetching schemes.

Development of Defogger Equipped with a Roller Horsehair Brush

  • Ma, Chang-Jin;Kasahara, Mikio;Cao, Renqiu
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.226-231
    • /
    • 2016
  • In order to remove fog often causes various troubles in our daily lives, the novel defog blower equipped the roller brush made of recycled horse's mane hair was developed. This work presents the overview of new defog devices and the experimental data obtained at two different kinds of defogging experiments. In the model experiment carried out at the enclosed cleanroom ($W5.9m{\times}L5.1m{\times}H2.4m$) targeted a vinyl house, fog was dissipated in less than 30 seconds in case with wind entrainment and two minutes 45 seconds in case without wind entrainment after running of the newly designed defog blower. When the demisting blower was run in a duct, it has an excellent mist sweeping qualities as well as a great removal effect for the background particles (89.5% and 65.4% scavenging rates for fine and coarse particles, respectively). It can be therefore said that the mist eliminator presented in this paper is ideal for use in the sealing space like a vinyl house and the industrial sites where required to remove both harmful mist and particle.

Measurement of Dynamic Compressive Properties of Apples using the Oscillatory Test

  • Lee, Jong-Whan;Tan, Jinglu;Waluyo, Sri
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.28-35
    • /
    • 2012
  • Purpose: This study performed the oscillatory test using the texture analyzer to characterize the viscoelastic behavior of apples such as the storage modulus (E'), the loss modulus (E"), the complex modulus (${\mid}E^*{\mid}$) and the energy dissipated per cycle ($W_{diss}$). Methods: The sinusoidal deformation with the frequency of 1-10 Hz and the maximum displacement of 0.1 mm were applied to the flesh tissues of Fuji, Golden Delicious and Red Delicious apples. The Lissajous figure was used to measure the phase angle(${\delta}$) between stress and strain curve. Results: Trigger force was critical to the measurement of the phase angle. E', E", ${\mid}E^*{\mid}$ and Wdiss were measured using the Lissajous figure and the phase angle. The complex modulus of Golden Delicious apple was significantly lower than those of Fuji apple and Red Delicious apple. Conclusions: Apple flesh was exhibiting more elasticity at low frequency, and more viscosity at high frequency. Dynamic compressive properties of Fuji apple were similar to those of Red Delicious apple but significantly different from those of Golden Delicious apple.

Association of UCP2 Polymorphisms with Type 2 Diabetes in Korean Subjects

  • Kim, Su-Won;Yoo, Min
    • Biomedical Science Letters
    • /
    • v.14 no.4
    • /
    • pp.239-242
    • /
    • 2008
  • Obesity results from a combination of genetic, environmental, and behavioral factors. Uncoupling proteins (UCP) are members of the larger family of mitochondrial anion carrier proteins (MACP). UCP separates oxidative phosphorylation from ATP synthesis with energy dissipated as heat, also referred to as the mitochondrial proton leak. UCP facilitates the transfer of anions from the inner to the outer mitochondrial membrane and the return transfer of protons from the outer to the inner mitochondrial membrane. Therefore, we investigated the genotype for the G>A polymorphism at the position -866 of UCP2 gene in Koreans and compared genotype of patients with control group. 50 patients (Male 22, Female 28), who previously underwent type 2 diabetcs (T2DM) and 30 controls (Male 14, Female 16) participated in this study. There was a weak significant association between -866 G>A polymorphism in UCP2 gene and T2DM. The present study shows that UCP2 -866 G>A polymorphism may not be associated with the pathogenesis of T2DM as opposed to the previous reports in other countries. Further studies with larger population may be needed for the development of diagnostic methods at genetic level such as DNA chip.

  • PDF

Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions (연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요)

  • 서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

Design and Control of Braking Chopper Circuit for Ventilation Inverter of Traction Control System (고속전철용 추진제어장치의 냉각용 인버터를 위한 제동초퍼 회로 설계 및 제어)

  • Cho, Sung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.314-315
    • /
    • 2011
  • This paper introduces the design and control method of braking chopper circuit which can supply input power to ventilation inverter of traction control system. The DC input voltage from auxiliary block (static inverter) is normally used as an input of ventilation inverter. It converts DC input to AC output voltage to drive cooling fans for traction control system and traction motors. The electrical braking force is very important for high speed train to guarantee safety even though the train is running in the dead section where the pantograph voltage is not supplied. When the high speed train decelerate speed in dead section, the regenerative energy is dissipated by braking resistor. This paper proposed the braking chopper control method to implement rheostatic braking function and the appropriate chopper circuit for supplying voltage source to ventilation inverter during rheostatic braking mode. The proposed chopper circuit makes it possible for traction control system to regenerate power continuously regardless of the existence of pantograph voltage. The feasibility of proposed braking chopper control and circuit were proven by inertia load test and actual train field test.

  • PDF

Influence of vertical load on in-plane behavior of masonry infilled steel frames

  • Emami, Sayed Mohammad Motovali;Mohammadi, Majid
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.609-627
    • /
    • 2016
  • Results of an experimental program are presented in this paper for the influence of vertical load on the in-plane behavior of masonry infilled steel frames. Five half-scaled single-story, single-bay steel frame specimens were tested under cyclic lateral loading. The specimens included four infilled frames and one bare frame. Two similar specimens as well as the bare frame had moment-resisting steel frames, while the remaining two specimens had pinned steel frames. For each frame type, one specimen was tested under simultaneous vertical and lateral loading, whereas the other was subjected only to lateral loading. The experimental results show that the vertical load changes the cracking patterns and failure modes of the infill panels. It improves dissipated hysteresis energy and equivalent viscous damping. Global responses of specimens, including stiffness and maximum strength, do no change by vertical loading considerably. Regarding the ductility, the presence of vertical load is ignorable in the specimen with moment-resisting frame. However, it increases the ductility of the infilled pinned frame specimen, leading to an enhancement in the m-factor by at least 2.5 times. In summary, it is concluded that the influence of the vertical load on the lateral response of infilled frames can be conservatively ignored.