• Title/Summary/Keyword: energy cost saving

Search Result 444, Processing Time 0.03 seconds

Analysis of the abroad and domestic research trends on climate change and its economical effect on the power plant (기후변화협약 시행에 따른 대응 방안 및 발전분야 영향 분석)

  • Woo, Kwangje;Hwang, Jae Dong;Jeong, Seok Yong;Jang, Gil Hong
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.43-49
    • /
    • 2001
  • To meet $CO_2$ emission regulation, this study describes the present state of $CO_2$ reduction technology and the effect of the regulation on power industry. In Japan, R&D investment is actively continuing through a long-term R&D project, along with trying to meet the reduction demand by the ways of energy saving and abroad business. EU has made a lot of investments in increasing the efficiency of power generation and developing alternative energy sources. The US is making provision of the portion of reduction by using energy saving program and emission trading, and the current DOE-driven program is addressing the development of cost-effective power systems. In the country, the research to reduce $CO_2$ emission has been mainly driven by the government and research institute supported by the government. Meanwhile, if the reduction obligation imposed on Portugal which is the least strict condition will be enforced in Korea, it is likely that about 50 running power plants should be stopped or shut down after 2015, in spite of voluntary reduction efforts such as conversion to clean fuels, etc. according to the government's long-term electric power need and supply plan.

  • PDF

Smart City Energy Inclusion, Towards Becoming a Better Place to Live

  • Cha, Sang-Ryong
    • World Technopolis Review
    • /
    • v.8 no.1
    • /
    • pp.59-70
    • /
    • 2019
  • Where is a better place to live? In the coming era, this should be more than simply a livable place. It should be an adaptable place that has a flexible system adaptable to any new situation in terms of diversity. Customization and real-time operation are needed in order to realize this technologically. We expect a smart city to have a flexible system that applies technologies of self-monitoring and self-response, thereby being a promising city model towards being a better place to live. Energy demand and supply is a crucial issue concerning our expectations for the flexible system of a smart city because it is indispensable to comfortable living, especially city living. Although it may seem that energy diversification, such as the energy mix of a country, is a matter of overriding concern, the central point is the scale of place to build grids for realizing sustainable urban energy systems. A traditional hard energy path supported by huge centralized energy systems based on fossil and nuclear fuels on a national scale has already faced difficult problems, particularly in terms of energy flexibility/resilience. On the other hand, an alternative soft energy path consisting of small diversified energy systems based on renewable energy sources on a local scale has limitations regarding stability, variability, and supply potential despite the relatively light economic/technological burden that must be assumed to realize it. As another alternative, we can adopt a holonic path incorporating an alternative soft energy path with a traditional hard energy path complimentarily based on load management. This has a high affinity with the flexible system of a smart city. At a system level, the purpose of all of the paths mentioned above is not energy itself but the service it provides. If the expected energy service is fixed, the conclusive factor in choosing a more appropriate system is accessibility to the energy service. Accessibility refers to reliability and affordability; the former encompasses the level of energy self-sufficiency, and the latter encompasses the extent of energy saving. From this point of view, it seems that the small diversified energy systems of a soft energy path have a clear advantage over the huge centralized energy systems of a hard energy path. However, some insuperable limitations still remain, so it is reasonable to consider both energy systems continuing to coexist in a multiplexing energy system employing a holonic path to create and maintain reliable and affordable access to energy services that cover households'/enterprises' basic energy needs. If this is embodied in a smart city concept, this is nothing else but smart energy inclusion. In Japan, following the Fukushima nuclear accident in 2011, a trend towards small diversified energy systems of a soft energy path intensified in order to realize a nuclear-free society. As a result, the Government of Japan proclaimed in its Fifth Strategic Energy Plan that renewable energy must be the main source of power in Japan by 2050. Accordingly, Sony vowed that all the energy it uses would come from renewable sources by 2040. In this situation, it is expected that smart energy inclusion will be achieved by the Japanese version of a smart grid based on the concept of a minimum cost scheme and demand response.

Practitioners' Awareness of Planning Features for Environment-Friendly Apartment unit (공동주택 단위주거의 친환경 계획요소에 대한 전문가 의식조사)

  • Kwon, O-Jin;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The purpose of this study was to find out awareness of the environment-friendly planning elements for residential unit space among practitioners. The respondents in this questionnaire survey were 140 practitioners in architecture and interior design field. The major findings of this study were as follows; most of the respondents were aware of the impact of indoor built environment on residents' wellness. In addition, the survey respondents viewed that the factors for planning environment-friendly high-rise apartments were represented by gardening and energy-saving while their perception on the concept excluded comprehensive components affecting residents' life quality. Over 50% of respondents had an experience of applying environment-friendly planning elements in their works, and high frequency appeared on the general planning elements which had been applied special awareness as pro-environmental features. The respondents considered environment-friendly planning elements as important. Specially, space planning and system were considered more likely important in interior design field. In application of environment-friendly planning elements, cost, lack of consumers' awareness of and underdevelopment of environment-friendly materials were of concern. Therefore, the consumer's cognition needs to be improved for wide application about environment-friendly planning element, and then consumers are willing to pay additional construction cost of environment-friendly apartments. At the same time, the current practice that housing developers pass the additional cost on to residents needs to be changed. Then, the quality of life in high-rise residential settings can be improved. More importantly, the exchange and development of the reliable information on environment-friendly planning elements need to be made, and technical support and long-term policy for the development are required. This research showed current status of knowledge and practice in sustainable planning of unit apartment and proved basic information for future direction.

A Study on Regional Distribution of the Ground Effective Thermal Conductivity (지중 유효 열전도도의 지역별 분포)

  • Kong, Hyoung Jin;Kwon, Soon-Ki;Ji, Seung Gyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • Ground source heat pump(GSHP) systems is known as environmental friendly and energy saving. Especially a ground heat exchanger is an important unit that determines the thermal performance of a system and initial cost. In design phase of vertical GSHP system, it is recommended that the effective borehole thermal resistance, be determined from in-situ thermal response test. In this study, ground effective thermal conductivity was categorized by a region. As a result of the study, the ground thermal conductivity of national average was analyzed as 2.56 W/mK. The highest regional average of thermal conductivity is 2.68 W/mK in Seoul, and the lowest is 2.28 W/mK in Busan. Also, the thermal conductivity on the coast has been analyzed approximately 30% lower than the average.

Development of Power Quality Measurement System for Harmonics Diagnosis of Electrical Equipment (전기설비의 고조파 진단을 위한 전력품질 측정시스템의 개발)

  • 유재근;이상익;전정채
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • Because of falling-off in power quality by harmonics, obstacles like lowering of capability, noise, vibration of power facilities and so on are occurred. Also generation of harmonics is inevitable and the point at harmonics is seriously gathering strength because energy saving installation using semiconductor circuit as countermeasures to enhance energy efficiency will be broadly spread and the use of energy conversion equipment like motor speed control contrivance, energy keeping installation and so on will increase, in the future. In order to eliminate harmonics obstacle, precision measurement and analysis on voltage, current, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion, and so forth are needed. In this paper, we developed low-cost measurement system to measure and analyze power quality connected with harmonics and verified it's performance by measuring and analyzing power quality in the three-phase and four-wire system.

Analysis of Temperature and Power Generation Characteristics of Bifacial BIPV System Applied into Curtain Wall (양면형 BIPV 시스템의 커튼월 적용에 따른 온도 및 발전특성 분석)

  • Kang, Jun-Gu;Kim, Yong-Jae;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.57-66
    • /
    • 2015
  • BIPV system not only produces electricity at building, but also acts as a material for building envelope. Thus, it can increase the economical efficiency of PV system by saving the cost for building materials. Bifacial solar cell can convert solar energy to electrical energy from both sides of the cell. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial solar cells. Therefore, many of the module manufacturers can easily use the bifacial solar cells without changing their manufacturing equipments. Moreover, bifacial PV system has much potential in building application by utilizing glass-to-glass structure of PV module. However, the electrical generation of the bifacial PV module depends on the characteristics of the building surface which faces the module, as well as outdoor environment. Therefore, in order to apply the bifacial PV module to building envelope as BIPV system, its power generation characteristics are carefully evaluated. For this purpose this study focused on the electrical performance of the bifacial BIPV system through the comparative outdoor experiments. As a result, the power generation performance of the bifacial BIPV system was improved by up to 21% compared to that of the monofacial BIPV system. Therefore, it is claimed that the bifacial BIPV system can replace the conventional BIPV system to improve the PV power generation in buildings.

Energy efficiency standard for imaging equipments using electrophotograph printing (전자사진 기술을 사용하는 이미징 장치의 에너지 효율 기준 연구)

  • Park, Jun-Young;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2433-2442
    • /
    • 2014
  • In this paper, an efficiency grade standard for imaging equipments using electrophotograph printing such as a printer, copier, fax, and MFD (Multi Function Device) is studied. By emphasizing domestic standby power reduction program's problem, and proposing the necessity of efficiency management, the efficiency standard is developed by reliable data registered in domestic standby power reducing program. To find an efficiency indication for grade, correlation analysis is used and as a result, printing speed has the biggest correlation coefficient. By applying the efficiency indication for grade, the proposed certification standard is established in 1st to 5th level products and super-high-efficiency product (energy frontier) which is better than 1st to 5th level products. If these efficiency standards are chosen by government policies, it is expected to save 65 billion won reduction of energy cost per year.

Performance of sequencing batch reactor under aeration-limited condition and characteristics of microbial community change (폭기 에너지 저감 연속회분식반응조 운전과 미생물 군집 변화 특성)

  • Hwang, Kuksun;Shin, Donghyeok;Jeong, Ingyo;Park, Sungje;Chang, Insoo;Kim, Jeongbae;Choi, Jeongdong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.215-224
    • /
    • 2019
  • Recent focus on wastewater treatment includes energy-saving and renewable energy generation for energy-independence of water infrastructures. Aeration and pumping in biological wastewater removal processes account for nearly 30-60% of the total electricity cost in real wastewater treatment plants. In this study, the performance and microbial characteristics were investigated in sequencing batch reactor under typical oxygen and oxygen limited condition. Under typical DO ($7.55{\pm}0.99mg/L$) and low DO ($0.23{\pm}0.08mg/L$) conditions, COD removal was stable over 91 % during SBR operation. Ammonia removal efficiency was reduced from 95.6 % to 89.2 % when DO concentration was dropped sharply. Phosphorus removal efficiency also reached 77% at oxygen-limited condition. The results indicated that removal efficiency both ammonia and phosphorus was influenced by DO condition. Microbial analysis revealed that Proteobacteria and Bacteroidetes at phylum level was dominant in typical DO and low DO conditions and DO concentration did not much affect phylum distribution. Population decrease of genera of nitrifying bacteria(Dokdonella) and Dechloromonas spp. affect removal efficiency of nitrogen and phosphorus at low DO condition.

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

Experimental Study on Energy Saving through FAN Airflow Control in the Generator Room of a 9200-ton Training Ship (9200톤급 실습선 발전기실 FAN 송풍유량 제어를 통한 선박에너지 절약에 관한 실험적 연구)

  • Moon-seok Choi;Chang-min Lee;Su-jeong Choe;Jae-jung Hur;Jae-Hyuk Choi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.697-703
    • /
    • 2023
  • As a part of the global industrial efforts to reduce environmental pollution owing to air pollution, regulations have been established by the International Maritime Organization (IMO). The IMO has implemented various regulations such as EEXI, EEDI, and CII to reduce air pollution emissions from ships. They are also promoting measures to decrease the power consumption in ships, aiming to conserve energy. Most of the power used in ships is consumed by electric motors. Among the motors installed on ships, the engine room blower that takes up a significant load, operates at a constant irrespective of demand. Therefore, energy savings can be expected through frequency control. In this study, we demonstrated the efficacy of energy savings by controlling the frequency of the electric motor of the generator blower that supplies combustion air to the generator's turbocharger. The system was modeled based on the output data of the turboharger outlet temperature in response to the blower frequency inpu. A PI control system was established to control the frequency with the target being the turbocharger outlet temperature. By maintaining the turbocharger design standard outlet temperature and controlling the blower frequency, we achieved an annual energy saving of 15,552kW in power consumption. The effectiveness of energy savings through frequency control of blower fans was verified during the summer (April to September) and winter (March to October) periods. Based on this, we achieved annual fuel cost savings of 6,091 thousand won and reduction of 8.5 tons of carbon dioxide, 2.4 kg of SOx, and 7.8 kg of NOx air pollutants on the training ship.