• 제목/요약/키워드: endocardium detection

검색결과 4건 처리시간 0.015초

B 모드 단축 심초음파 영상의 좌심실 내벽 윤곽선 자동 검출 (Automatic Detection of Left Ventricular Endocardial Boundary on B-mode Short Axis Echocardiography)

  • 김명남;원철호;조진호
    • 전자공학회논문지B
    • /
    • 제32B권10호
    • /
    • pp.1294-1304
    • /
    • 1995
  • In this paper, a method has been proposed for the fully automatic detection of left ventricular endocardial boundary in B-mode short axis echocardiography without manual intervention by human operator. The proposed method makes use of the weighted model that approximates to endocardium and incomplete edge information for echocardiography. Therefore, this method is more effective than boundary detection by only edge information. The implementation of this method is as follows. First, the proposed algorithms are used in order to detect the approximate boundary, then a weighted model with the approximate boundary is constructed. Finally, the cavity center of the left ventricle performing the Hough transform with the weighted model and edge image can be found automatically, and then the endocardial boundary using detected center, original image, weighted model, and edge image can be detected. validations of this method with experimental results on echo image of dog's heart and clinical echocardiography is verified.

  • PDF

Murine Heart Wall Imaging with Optical Coherence Tomography

  • Kim Jee-Hyun;Lee Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 2006
  • M-mode imaging of the in vivo murine myocardium using optical coherence tomography (OCT) is described. Application of conventional techniques (e.g. MRI, Ultrasound imaging) for imaging the murine myocardium is problematic because the wall thickness is less than 1.5 mm (20 g mouse), and the heart rate can be as high as six hundred beats per minute. To acquire a real-time image of the murine myocardium, OCT can provide sufficient spatial resolution ($10{\mu}m$) and imaging speed (1000 A-scans/s). Strong light scattering by blood in the heart causes significant light attenuation, which makes delineation of the endocardium-chamber boundary problematic. To measure the thickness change of the myocardium during one heart beat cycle, a myocardium edge detection algorithm is developed and demonstrated.

가중모델 Hough 변환을 이용한 2D 심초음파도에서의 좌심실 윤곽선 자동 검출 (Automatic Detection of Left Ventricular Contour Using Hough Transform with Weighted Model from 2D Echocardiogram)

  • 김명남;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권3호
    • /
    • pp.325-332
    • /
    • 1994
  • 본 논문에서는 2D 심초음파영상으로 부터 가중모델을 검출하고 이 모델로써 Hough변환을 수행하여 좌심실의 심내벽윤곽을 검출하는 방법을 제안하였다. 제안된 방법의 수행은 다음과 같이 크게 두단계로 나누어진다. 첫번째 단계에서는 근사적인 심내벽 모델과 모델의 중심을 검출하기 위하여 근사모델 검출 알고리듬이 수행되고 그런다음, 검출된 모델로써 가중모델을 구성한다. 두번째 단계에서는 가중모델과 에지영상을 이용한 Hough변환을 수행하므로써 좌심실 동공의 중심을 자동적으로 찾은 다음, 가중모델, 에지영상 및 동공의 중심과 같은 지식을 이용하여 심내벽 윤곽을 검출하였다.

  • PDF

심초음파에서 국소 좌심실벽 운동 추적 및 정량적 분석에 관한 연구 (A Study on Tracking and Quantitative Analysis of Regional Left Ventricular Wall Motion in Echocardiography)

  • 신동규;김동윤;최경훈;박광훈
    • 한국의학물리학회지:의학물리
    • /
    • 제10권3호
    • /
    • pp.115-123
    • /
    • 1999
  • 2 차원 심초음파는 좌심실벽 운동을 실시간으로 보여줄 수 있어 국소 좌심실벽 운동장애를 진단하는 데 널리 사용되고 있다. 심초음파를 통하여 국소 좌심실벽 운동기능을 평가하고 정량화하기 위한 많은 연구들이 진행되어왔다. 본 논문에서는 국소 좌심실벽 운동장애의 진단을 위한 좌심실벽 운동 추 적 및 정량적 분석 알고리듬을 제안하였다. 정상 피검자들과 국소 좌심실벽 운동이상 환자로부터 얻은 심초음파 흉골연단축단면 영상들이 알고리듬의 시험을 위해 사용되었다. 자동화된 경계선 검출과 좌심실내벽 윤곽선 연결 알고리듬을 각 프레임들에 적용하였고 영역분할에 기초한 정량적 분석을 수행하였으며 운동량을 의미하는 칼라가 프레임 및 영역별로 심초음파 영상들 위에 덧씌워졌고 칼라화된 영상들이 동영상으로 구현되었다. 제안된 알고리듬은 좌심실벽 운동장애의 자동화된 정량적 진단을 제공하였다.

  • PDF