• Title/Summary/Keyword: enclosed space

Search Result 153, Processing Time 0.021 seconds

A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Summer - Without Cooling Loads from Occupancy - (대규모 실내경기장의 하계 온열환경 특성 실측조사 - 인체부하 미고려 조건 -)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.91-101
    • /
    • 2007
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with and without cooling the space in summer. Colling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space (공조공간에서 수평토출형 에어커튼의 차단 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

Automatic Calculation of Interior Volume of Refrigerator by Hole Filling Algorithm (분해모델과 구멍 메움 알고리즘을 이용한 냉장고 내부 용적의 자동 계산)

  • Park, Raesung;Fu, Jianhui;Jung, Yoongho;Park, Mingeun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.22 no.1
    • /
    • pp.59-69
    • /
    • 2017
  • Internal capacity of a refrigerator is an important indicator for design and purchasing criteria. The components facing the internal space may have holes or gaps between parts. In traditional way, design engineers manually remodeled the parts to fill the holes and the gaps for enclosed boundary of the internal space. Then they calculated internal volume by subtracting the assembly of parts from its enclosing volume. However, filling holes and gaps is not an automated process requiring a plenty of labor and time. In this research, we have developed a voxel-based method to estimate the internal volume of a refrigerator automatically. It starts transforming all components facing the interior space into voxels and fills all holes and gaps automatically by the developed hole-filling algorithm to form a completely closed boundary of the assembly. Then, it identifies the boundary voxels that are facing to the internal voxels with any part of the component. After getting the intersection points between the boundary voxels and the surfaces of components, it generates the boundary surface of triangular facets with the intersection points. Finally, it estimates the internal volume by adding volume of each tetrahedron composed of a triangle of boundary surface and an arbitrary point.

Longitudinal Modal Analysis of a LOX-filled Tank Using the Virtual Mass Method

  • Lee, SangGu;Sim, JiSoo;Shin, SangJoon;Kim, Youdan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.807-815
    • /
    • 2017
  • For liquid rocket engine(LRE)-based space launch vehicles, longitudinal instability, often referred to as the pogo phenomenon in the literature is predicted. In the building block of system-level task, accurate dynamic modeling of a fluid-filled tank is an essential. This paper attempts to apply the virtual mass method that accounts for the interaction of the vehicle structure and the enclosed liquid oxygen to LOX-filled tanks. The virtual mass method is applied in a modal analysis considering the hydroelastic effect of the launch vehicle tank. This method involves an analysis of the fluid in the tank in the form of mass matrix. To verify the accuracy of this method, the experimental modal data of a small hemispherical tank is used. Finally, the virtual mass method is applied to a 1/8-scale space shuttle external tank. In addition, the LOX tank bottom pressure in the external tank model is estimated. The LOX tank bottom pressure is the factor required for the coupling of the LOX tank with the propulsion system. The small hemispherical tank analysis provides relatively accurate results, and the 1/8-scale space shuttle external tank provides reasonable results. The LOX tank bottom pressure is also similar to that in the numerical results of a previous analysis.

Passive Smoking in Poorly Ventilated Room Space (환기(換氣)가 불량(不良)한 실내(室內)에서의 간접흡연(間接吸煙)에 관(關)하여)

  • Rhee, Jung-Ae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.14 no.1
    • /
    • pp.23-31
    • /
    • 1981
  • This study was conducted to investigate the effects of passive inhalation of cigarette smoke and the correlation between change of flicker value and active or passive smoking in poorly ventilated room. Forty five male students were tested by divided into four experimental groups composed of active and passive smokers and three control groups. Each four experimental groups were exposed to smoke for Two hours in enclosed room. Vital capacities, flicker values, blood carboxyhemoglobin levels and carbon monoxide concentration in room air were estimated before, during and after the exposure, and amounts of smoking or smoke exposure during two hours were also noted. The results obtained were as follows; 1. Concentration of carbon monoxide in air and increase of blood carboxyhemoglobin level (% COHb) were positively correlated with smoking amount. 2. Increase of blood carboxyhemoglobin in passive smokeres, in average, were about seventy six percent of that in smokers, as 2.2% vs. 2.9%. 3. Comparison with published data showed that Peterson's equation gave most similar result to this study in estimation of increase of blood carboxyhemoglobin level. 4. During the exposure, flicker values fell steadily in both experimental groups and control groups as time passed. Flicker values were, however, elevated again in experimental groups after exposure, despite the fact that values still fell in control groups. 5. Blood carboxyhemoglobin and flicker value were negatively correlated and this correlationship was stronger in passive smoker than in active smoker. 6. Multiple regression equation between flicker value and exposure time and blood carboxyhemoglobin level was expressed as: Flicker value=41.6-0.2 COHb%-0.9Hour, 7. In general, it is suggested that biological criteria would be more preferrable than chemical criteria in establishment of statutory limitation of smoking in enclosed spaces.

  • PDF

A Study on the Characteristics of Interior Elements of Frank Lloyd Wright's Residential Design (F. L. Wright의 주택특성과 실내디자인 요소분석에 관한 연구)

  • 서수경
    • Korean Institute of Interior Design Journal
    • /
    • no.5
    • /
    • pp.45-52
    • /
    • 1995
  • Frank Lloyd Wright, a master of the 20th Century Ar-chitecture, contributed tremendously in creating a wholly new form of American architecture called Prairie Style. His idea behind the development of the building structur-al system, organic relationships between inner and outer space, horizontal vertical lines, and idea of extending and expanding interior spaces came from nature. He had completed over 390 projects throughout his life and 90% of those projects were residential design. The most typical characteristic shared by many of his residential design was that each design element, whether it is functional or aesthetical, has close relationship to or-ganic nature, human scale, theoretical floor plants, and maximum emphasis on horizontal lines in respect to na-ture. His concept of "flow of spaces" reformed common the-ory of room next to room in a enclosed space. His sense of "wall" was no longer the side of a box. Careful selec-tion of finishing materials, colors, and natural images en-hance the design as well. F.L. Wright was an artist, designer, and architect who believed the exterior space should have direct relationship to the interior space. His architectural philosophy was not only to design exterior of architecture but also to ful-fill his space through the careful development of interior elements such as furniture, and lighting fixture. Even the patterns for leaded glass windows were designed to have unified appearance from outside to inside of the house. The objective of this study was to analyze floor plans, spatial organizations, and interior design elements of the houses which represent the best of F.L. Wright's design principles and philosophy behind Prairie Style. The meth-od used to collect informations for this study was based on books, articles, journals, and actual site visits. actual site visits.

  • PDF

A Study on the Performance of Ramp Tabs Asymmetrically Installed in the Supersonic Nozzle Exit (초음속 노즐 출구에 비대칭적으로 설치한 램프 탭의 성능 연구)

  • Kim, Kyoung-Rean;Ko, Jae-Myoung;Park, Jong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.10
    • /
    • pp.934-939
    • /
    • 2007
  • Thrust vector control(TVC) is the method which generates the side force and moment by controlling the exhausting gas directly from the supersonic nozzle to change the trajectory of a missile quickly. In this paper, performance study on the tapered ramp tabs asymmetrically installed in the supersonic nozzle exhaust for the thurst vector control has been carried out using the supersonic cold flow system. To study the shock wave structure and location of the oblique shock wave produced by the ramp tab, the flow field visualization using the schlieren system is conducted. This paper provides the thrust spoilage, three directional forces and moments and distribution of surface pressure on the region enclosed by the tapered ramp tabs.

A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer (대공간내 인체발열 미고려시의 하계 온열환경 조사)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.3-8
    • /
    • 2008
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with cooling the space in summer. Cooling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

A Study on Influential Factors of Egress Behavior in Respect of the Fire Prevention Manager in the Large-scale Shopping Mall (대규모 판매시설의 방화관리자의 측면에서 본 피난행동 영향요인에 대한 연구)

  • 박재성;윤명오
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.108-113
    • /
    • 2004
  • Emergency response of fire prevention manager has an effect on decisive emergency exit behavior of customer who is not accustomed to emergency response in a large-scale shopping department on fire. Especially enclosed stairways in a large scale store are usually located in back space where is impossible for customer to access. Therefore, speedy emergency exit inducement by fire prevention manager is needed for the customer's safe egress. The object of study is to analyse the factors affecting egress behavior and emergency response of fire prevention manager in respect of fire prevention management.

Effects of Surface Radiation on the Unsteady Natural Convection in a Rectangular Enclosure

  • Baek, Seung-Wook;Kim, Taig-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • Numerical solution of the full Navier-Stokes equation as well as the energy equation has been obtained for the unsteady natural convection in a rectangular enclosure. One side wall was maintained at very high temperature simulating fires. Especially the effect of surface radiation was taken into account. While the enclosed air was assumed to be transparent, the internal walls directly interacted one another through the surface radiation. Due to a significant temperature difference in the flow field, the equation of state was used instead of the Boussinesq approximation. It was found that the rapid heating of the adiabatic ceiling and floor by the incoming radiation from the hot wall made the evolution at thermo-fluid field highly unstable in the initial period. Therefore, the secondary cells brought about at the floor region greatly affected the heat transfer mechanism inside the enclosure. The heat transfer rate was augmented by the radiation, resulting in requiring less time for the flow to reach the steady state. At the steady state neglecting radiation two internal hydraulic jumps were clearly observed in upper/left as well as in lower/right comer. However, the hydraulic jump in the lower/right comer could not be observed for the case including radiation due to its high momentum flow over the bottom wall. Radiation resulted in a faster establishment of the steady state phenomena.