• Title/Summary/Keyword: emission stability

Search Result 573, Processing Time 0.03 seconds

High-Rate Blended Cathode with Mixed Morphology for All-Solid-State Li-ion Batteries

  • Heo, Kookjin;Im, Jehong;Lee, Jeong-Seon;Jo, Jeonggeon;Kim, Seokhun;Kim, Jaekook;Lim, Jinsub
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.282-290
    • /
    • 2020
  • In this article, we report the effect of blended cathode materials on the performance of all-solid-state lithium-ion batteries (ASLBs) with oxide-based organic/inorganic hybrid electrolytes. LiFePO4 material is good candidates as cathode material in PEO-based solid electrolytes because of their low operating potential of 3.4 V; however, LiFePO4 suffers from low electric conductivity and low Li ion diffusion rate across the LiFePO4/FePO4 interface. Particularly, monoclinic Li3V2(PO4)3 (LVP) is a well-known high-power-density cathode material due to its rapid ionic diffusion properties. Therefore, the structure, cycling stability, and rate performance of the blended LiFePO4/Li3V2(PO4)3 cathode material in ASLBs with oxidebased inorganic/organic-hybrid electrolytes are investigated by using powder X-ray diffraction analysis, field-emission scanning electron microscopy, Brunauer-Emmett-Teller sorption experiments, electrochemical impedance spectroscopy, and galvanostatic measurements.

Efficient Green Phosphorescent OLEDs with Hexaazatrinaphthylene Derivatives as a Hole Injection Layer (Hexaazatrinaphthylene 유도체를 정공 주입층으로 사용한 고효율 녹색 인광 OLEDs)

  • Lee, Jae-Hyun;Lee, Jonghee
    • Applied Chemistry for Engineering
    • /
    • v.26 no.6
    • /
    • pp.725-729
    • /
    • 2015
  • Organic light emitting diodes (OLEDs) are regarded as the next generation display and solid-state lighting due to their superb achievements from extensive research efforts on improving the efficiency and stability of OLEDs in addition to developing new materials. Herein, efficient green phosphorescent OLEDs were obtained by using hexaazatrinaphthylene (HAT) derivatives as a hole injection layer. External quantum and current efficiencies of OLEDs were enhanced from 8.8% and 30.8 cd/A to 13.6% and 47.7 cd/A, respectively by inserting a thin layer of HAT derivatives between the ITO and hole transporting layer. The enhancement of OLEDs was found to be originated from the inserted HAT derivatives, which resulted in the optimized hole-electron balance inside the emission layer.

A Compact Tunable VCSEL and a Built-in Wavelength Meter for a Portable Optical Resonant Reflection Biosensor Reader

  • Ko, Hyun-Sung;Kim, Bong-Kyu;Kim, Kyung-Hyun;Huh, Chul;Kim, Wan-Joong;Hong, Jong-Cheol;Park, Seon-Hee;Yang, Seong-Seok;Jang, Ho-Jin;Sung, Gun-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.395-402
    • /
    • 2010
  • This study reports a portable and precision photonic biosensor reader that can measure the concentration of a particular antigen using an optical resonant reflection biosensor (ORRB). To create a compact biosensor reader, a compact tunable vertical-cavity surface-emitting laser (VCSEL) and a compact built-in wavelength meter were manufactured. The wavelength stability and accuracy of the compact built-in wavelength meter were measured to be less than 0.02 nm and 0.06 nm, respectively. The tunable VCSEL emission wavelength was measured with the compact built-in wavelength meter, it has a fast sweep time (~ 10 seconds) and a wide tuning range (> 4 nm) that are sufficient for biosensor applications based on ORRB. The reflection spectrum of a plastic based ORRB chip was measured by the fabricated portable photonic biosensor reader using the VCSEL and wavelength meter. Although the reader is the size of a palmtop device, it could make a precise measurement of the peak wavelength on equal terms with a conventional bulky optical spectrometer.

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Characteristics of Non-premixed Synthetic Natural Gas-Air Flame with Variation in Fuel Compositions (합성천연가스의 조성변화에 따른 확산화염 연소특성)

  • Oh, Jeongseog;Dong, Sangeun;Yang, Jebok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.829-836
    • /
    • 2013
  • The combustion characteristics with variations in synthetic natural gas (SNG) compositions were studied in a lab-scale combustor. The objective of the current study is to investigate the flame stabilization, flame structure, and spectrometry in a non-premixed SNG flame with varying fuel compositions. For the analysis of light emission in SNG flames, we used a spectrometer. As experimental conditions, the fuel jet velocity at the nozzle exit $u_F$ was varied from 5 to 40 m/s and the coaxial air velocity $u_A$ was varies from 0 to 0.43 m/s. The experiments showed that the flame stability increased with the hydrogen component in SNG.

Incompatible deformation and damage evolution of mixed strata specimens containing a circular hole

  • Yang, Shuo;Li, Yuanhai;Chen, Miao;Liu, Jinshan
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.461-474
    • /
    • 2020
  • Analysing the incompatible deformation and damage evolution around the tunnels in mixed strata is significant for evaluating the tunnel stability, as well as the interaction between the support system and the surrounding rock mass. To investigate this issue, confined compression tests were conducted on upper-soft and lower-hard strata specimens containing a circular hole using a rock testing system, the physical mechanical properties were then investigated. Then, the incompatible deformation and failure modes of the specimens were analysed based on the digital speckle correlation method (DSCM) and Acoustic Emission (AE) data. Finally, numerical simulations were conducted to explore the damage evolution of the mixed strata. The results indicate that at low inclination angles, the deformation and v-shaped notches inside the hole are controlled by the structure plane. Progressive spalling failure occurs at the sidewalls along the structure plane in soft rock. But the transmission of the loading force between the soft rock and hard rock are different in local. At high inclination angles, v-shaped notches are approximately perpendicular to the structure plane, and the soft and hard rock bear common loads. Incompatible deformation between the soft rock and hard rock controls the failure process. At inclination angles of 0°, 30° and 90°, incompatible deformations are closely related to rock damage. At 60°, incompatible deformations and rock damage are discordant due that the soft rock and hard rock alternately bears the major loads during the failure process. The failure trend and modes of the numerical results agree very well with those observed in the experimental results. As the inclination angles increase, the proportion of the shear or tensile damage exhibits a nonlinear increase or decrease, suggesting that the inclination angle of mixed strata may promote shear damage and restrain tensile damage.

Modeling and Control Method for High-power Electromagnetic Transmitter Power Supplies

  • Yu, Fei;Zhang, Yi-Ming
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.679-691
    • /
    • 2013
  • High-power electromagnetic transmitter power supplies are an important part of deep geophysical exploration equipment. This is especially true in complex environments, where the ability to produce a highly accurate and stable output and safety through redundancy have become the key issues in the design of high-power electromagnetic transmitter power supplies. To solve these issues, a high-frequency switching power cascade based emission power supply is designed. By combining the circuit averaged model and the equivalent controlled source method, a modular mathematical model is established with the on-state loss and transformer induction loss being taken into account. A triple-loop control including an inner current loop, an outer voltage loop and a load current forward feedback, and a digitalized voltage/current sharing control method are proposed for the realization of the rapid, stable and highly accurate output of the system. By using a new algorithm referred to as GAPSO, which integrates a genetic algorithm and a particle swarm algorithm, the parameters of the controller are tuned. A multi-module cascade helps to achieve system redundancy. A simulation analysis of the open-loop system proves the accuracy of the established system and provides a better reflection of the characteristics of the power supply. A parameter tuning simulation proves the effectiveness of the GAPSO algorithm. A closed-loop simulation of the system and field geological exploration experiments demonstrate the effectiveness of the control method. This ensures both the system's excellent stability and the output's accuracy. It also ensures the accuracy of the established mathematical model as well as its ability to meet the requirements of practical field deep exploration.

Analytical Performance Evaluation of Pneumatic Nebulizers and Comparison of Their Characteristics (가압분무기의 성능 평가와 특성 비교)

  • Park, Chang Joon;Han, Myung Sub;Song, Sun Jin;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.120-126
    • /
    • 2002
  • The analytical performance of four commercially-available pneumatic nebulizers(Meinhard, Cross-flow, Babington, ESI PFA) was evaluated using inductively coupled plasma-atomic emission spectrometry (ICP-AES) and ICP-mass spectrometry (ICP-MS) instruments. The performance of an inert concentric nebulizer and a modified conespray nebulizer, made in Korea Research Institute of Standards and Science (KRISS), is compared with that of the four commercial nebulizers. Variation of sample introduction efficiency was investigated as carrier argon pressure and sample uptake rate were changed. Variation of sensitivity, signal stability, blank intensity and oxide/hydride ratios were also studied when the nebulizers were connected to the ICP-MS and ICP-AES instruments. It was found that good analytical result such as high sensitivity, low blank, stable signal and so on can be obtained with judicious selection of the nebulizer depending on the type of sample, sample amount, type of analytical instrument and analyte.

Usefulness of Labeled RBC-SPECT Scanning in the Diagnosis of Hepatic Hemangiomas (간혈관종 진단에 있어서의 표지 적혈구 SPECT 스캔의 유용성)

  • Kim, Hyeon-Sook;Yang, Woo-Jin;Lee, Myung-Hee;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.61-67
    • /
    • 1991
  • The usefulness of $^{99m}Tc-labeled$ RBC single photon emission CT (SPECT) scanning in the diagnosis of hepatic heminagiomas was evaluated in 22 patients with various focal hepatic lesions including 15 cases of hemangiomas, 3 cases each of hepatomas and metastasis and 1 case of abscess. The diagnoses were based on ultrasonography and/or CT scanning, clinical stability of lesion for at least 6 months or surgical exploration. Seven cases of 15 hemangiomas were detected by delayed planar RBC scanning, whereas 4 cases were detected by delayed RBC-SPECT scanning. The smallest hemangioma shown by delayed RBC-SPECT scanning was 1.0 cm in diameter. compared with 2.2 cm by planar RBC scanning. One small hemangioma (2.0 cm) located adjacent to the heart was not found by either method. The sensitivities in detecting the hemangioma according to the site by planar imaging were 16.6% $(1.0\sim1.9cm)$, 66.7% $(2.0\sim2.9cm)$ and 83.3% (more than 3.0 cm) and by SPECT were 50.0%, 66.7% and 100%, respectively. Seven cases of non-hemangiomatous lesions did not show any significant increase in activity in the delayed blood pool images. It is concluded that $^{99m}Tc-RBC$ blood-pool SPECT scanning is clearly more sensitive in detecting small hemangioma than planar scanning and is, therefore, a choice of method for the detection of hepatic hemangioma.

  • PDF

Study on the $N_2$ Plasma Treatment of Nanostructured $TiO_2$ Film to Improve the Performance of Dye-sensitized Solar Cell

  • Jo, Seul-Ki;Roh, Ji-Hyung;Lee, Kyung-Joo;Song, Sang-Woo;Park, Jae-Ho;Shin, Ju-Hong;Yer, In-Hyung;Park, On-Jeon;Moon, Byung-Moo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.337-337
    • /
    • 2012
  • Dye sensitized solar cell (DSSC) having high efficiency with low cost was first reported by Gr$\ddot{a}$tzel et al. Many DSSC research groups attempt to enhance energy conversion efficiency by modifying the dye, electrolyte, Pt-coated electrode, and $TiO_2$ films. However, there are still some problems against realization of high-sensitivity DSSC such as the recombination of injected electrons in conduction band and the limited adsorption of dye on $TiO_2$ surface. The surface of $TiO_2$ is very important for improving hydrophilic property and dye adsorption on its surface. In this paper, we report a very efficient method to improve the efficiency and stability of DSSC with nano-structured $TiO_2$. Atmospheric plasma system was utilized for nitrogen plasma treatment on nano-structured $TiO_2$ film. We confirmed that the efficiency of DSSC was significantly dependent on plasma power. Relative in the $TiO_2$ surface change and characteristics after plasma was investigated by various analysis methods. The structure of $TiO_2$ films was examined by X-ray diffraction (XRD). The morphology of $TiO_2$ films was observed using a field emission scanning electron microscope (FE-SEM). The surface elemental composition was determined using X-ray photoelectron spectroscopy (XPS). Each of plasma power differently affected conversion efficiency of DSSC with plasma-treated $TiO_2$ compared to untreated DSSC under AM 1.5 G spectral illumination of $100mWcm^{-2}$.

  • PDF