• Title/Summary/Keyword: emission line spectrum

Search Result 77, Processing Time 0.026 seconds

Wavelength-resolved Thermoluminescence of Chemical-vapor-deposited Diamond Thin Film (화학증착된 다이어몬드 박막의 파장 분해된 열자극발광)

  • Cho, Jung-Gil;Yi, Byong-Yong;Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Diamond thin films were synthesized by a chemical vapor deposition (CVD). Raman spectrum showed the diamond line at 1332 $cm^{-1}$ / and x-ray diffraction pattern exhibited a strong (111) peak of diamond. The scanning electron microscopy analysis showed that the CVD diamond thin film was grown to be unepitaxial crystallites with pyramidal hillocks. A wavelength-resolved thermoluminescence (TL) of the CVD diamond thin film irradiated with X-rays showed one peak at 430 nm around 560 K. The glow curve of the CVD diamond thin film produced one dominant 560-K peak that was caused by first-order kinetics. Its activation energy and the escape frequency were calculated to be 0.92 ~ 1.05 eV and 1.34 $\times$ 10$^{7}$ sec$^{-1}$ , respectively. The emission spectrum at 560 K was split into 1.63-eV, 2.60-eV, and 3.07-eV emission bands which is known to be attribute to silicon-vacancy center, A center, and H3 center, respectively.

  • PDF

Property of Optical Spectroscopy on the Lanthanum Tungstate doped Eu3+ Ion (Eu3+ 이온이 첨가된 란타넘텅스텐산화물의 분광학 특성)

  • Seo, Hyojin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2015
  • $La_2W_3O_{12}:Eu^{3+}$ phosphors were prepared by solid state reaction method. The crystal structure was characterized by XRD pattern and ICSD card (78180). Luminescence properties of $La_2W_3O_{12}:Eu^{3+}$ are investigated by optical and laser-excitation spectroscopy in which emission and excitation spectra and time-resolved spectra are measured. The 1 mol % $Eu^{3+}$-doped $La_2W_3O_{12}$ phosphor exhibits broad excitation band peaking at 286 nm due to the ligand-to-metal charge transfer transition. The excitation lines due to the $^7F_0{\rightarrow}{^5D_4},{^5D_4},{^5L_6},{^5G_4},{^5D_3},{^5D_2}$ transitions of $Eu^{3+}$ are observed in the wavelength region 350-500 nm. The strong line emission is observed at 618 nm corresponding to the due to the $^5D_0{\rightarrow}^7F_2$ transition. The lifetime of 618 nm emission decreases with increasing temperature as 7 K ($114{\mu}s$), 100 K ($94{\mu}s$), 200 K ($10{\mu}s$) and 300 K ($0.5{\mu}s$).

A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism

  • Liu, Hongyu;Chen, Yao;Cho, Kyungsuk;Feng, Shiwei;Vasanth, Veluchamy;Koval, Artem;Du, Guohui;Wu, Zhao;Li, Chuanyang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.52.2-53
    • /
    • 2018
  • A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB ) of this burst is extremely high, over 10^11K at 150 MHz and over 10^8K in general. The degree of circular polarization (q ) is between -60%~-100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3~-4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.

  • PDF

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

In Vitro Study of Fluorescence Detection for Protoporphyrin IX Induced from 5-Aminolevulinic Acid in Cancerous and Normal Cells (정상 및 암 세포주에서의 5-Aminolevulinic Acid에 의해 유도된 Protoporphyrin IX의 형광 검출을 위한 In Vitro 연구)

  • Kim, Myung-Hwa;Kim, Hyun-Jeong;Lee, In-Seon;Kim, Kyung-Chan;Lee, Chang-Seop
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.171-174
    • /
    • 2006
  • To clarify the usefulness of fluorescent diagnosis for cancer, We investigated the optimal method of administrating 5-aminolevulinic acid(5-ALA) by analyzing fluorescence signal of Protoporphyrin IX(PpIX) in the cultured normal and cancer cells. 5-ALA was injected as a photosensitizer to the cervico-uterine cancer cell line(HeLa) and in normal liver cells(Chang). Chang and HeLa cells were incubated with various concentrations of 5-ALA($0-800{\mu}g/ml$). The accumulation of PpIX induced by 5-ALA was in HeLa and Chang cells. The cell viability was measured by MTT assay. The optimal concentration of ALA that induced maximum levels of PpIX was $50{\mu}g/ml$ in HeLa cell cultured for 24 hours after 5-ALA injection. Fluorescence of PpIX in HeLa cell was excited at a wavelength(${\lambda}$=410 nm) and showed an emission spectrum at 602.3 nm, 659.9 nm which could be related to the PpIX generation induced by the applied 5-ALA. The experimental results showed that fluorescence signal of PpIX was proportional to the concentration of 5-ALA in cancer cells, but measured with low concentration in normal cells.

A study of ubiquitous-RTLS system for worker safety (작업자 안전관리를 위한 유비쿼터스-실시간 위치추적시스템 연구)

  • Kim, Young-Baig
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1C
    • /
    • pp.1-7
    • /
    • 2012
  • At the industrial work site, the manufacturing process is being automated to improve work efficiency. However, it is often difficult to automate the entire manufacturing process, and there are spaces in which workers there are constantly exposed to danger. To protect such workers from the danger, this paper studied a worker safety management system for the industrial work site which uses a location recognition system and which is based on the Ubiquitous-Wireless Sensor Network (U-WSN). Using wireless signals, the distance between two devices can be measured and the location of a worker can be calculated using triangularization in 3-D. But at the industrial work sites where there are a lot of steel and structures, errors occur due to signal reflection and multi-path, etc., which makes it difficult to get the accurate location. To address this problem the following was done: first, a circular polarization patch antenna appropriate to the work site was used to reduce the degree of error that may occur from the antenna emission pattern and the particular Line of Sight (LOS); second, a 3-D localization technique and a filtering algorithm were used to improve the accuracy of location determination. The developed system was tested by using it on a wharf crane to validate its accuracy and effectiveness. The proposed location recognition system is expected to contribute greatly in ensuring the safety of workers at industrial work sites.