Accumulation of Thallium-201 in Hemorrhagic Cerebral Infarction (Thallium-201 brain SPECT에서 양성 소견을 보인 출혈성 뇌경색)

  • Lee, Ki-Yeol;Kim, Kyung-Min;Choe, Jae-Gol;Chung, Yong-Gu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.337-340
    • /
    • 1999
  • Thallium-201 brain SPECT is utilized in the diagnosis of brain tumor especially in cases where CT or MRI findings alone cannot differentiate malignant lesion from benign. Recently we came across two cases of positive T1-201 brain SPECT in clinically suspected brain tumor patients that turned out to be hemorrhagic cerebral infarction instead on biopsy. The findings in these cases demonstrate that thallium-201 accumulation may occur by the breakdown of the blood-brain barrier and phagocytic cell infiltration in the liquefaction stage of infarction.

  • PDF

Case of Complete Remission of Breast Cancer Metastasized to Lung Treated by Traditional Korean Therapy (한방 치료로 완전관해에 이른 폐로 전이된 유방암 1례)

  • Han, Jae Bok;Ha, Tai Hyoun;Kim, Sung Su;Seong, Shin
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.818-822
    • /
    • 2013
  • This report is aimed to investigate the effect of Traditional Korean Therapy (TKT) in treating recurred breast cancer metastasized to lung. A 53-year-old woman who was diagnosed as left breast cancer and underwent surgery, adjuvant chemotherapy and radiotherapy in early 2009 was admitted for the treatment of recurred, metastatic lung cancer in late 2012. She was treated with TKT including acupuncture, moxibustion and pharmacopuncture. The effect was evaluated with positron emission tomogram and computed tomogram (PET-CT). The metastatic tumors in both lungs were disappeared after the treatment for about 2 months. These results suggest that TKT is a therapeutic method to treat metastatic lung cancer originated from breast cancer.

Application of Weighted Sum of Gray Gases Model with Gray Gas Regrouping for Opposed Flow Flames (대향류화염에서의 회색가스재조합 회색가스가중합법의 적용)

  • Park, Won-Hee;Kim, Tae-Kuk
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.9-17
    • /
    • 2005
  • WSGGM with gray gas regrouping is successfully applied to study the flame structure of opposed flow flames including effect of radiative transfer. The statistical narrow band model is used to obtain the benchmark solutions. Results obtained by using the optically thin model are shown to overestimate the emission and to predict the flame structures inadequately especially for optically thick and low stretch rate flames. Computed results by using the WSGGM with 10 gray gases and SNB model show reasonable agreements with each other, and the required calculation time for the WSGGM is acceptable for engineering applications.

  • PDF

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

Total En Bloc Lumbar Spondylectomy of Follicular Thyroid Carcinoma

  • Jo, Dae-Jean;Jun, Jae-Kyun;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.188-191
    • /
    • 2009
  • The presence of distant metastases from differentiated thyroid carcinoma decreases the 10-year survival rates of patients by 50%. This is a report of a 61-year-old female with follicular thyroid carcinoma who presented initially with low back pain. 2-deoxy-2-[18F] fluoro-D-glucose whole-body positron emission tomography/computed tomography (PET/CT) demonstrated a hypointensity lesion in the left thyroid gland with malignant uptake in L1 vertebra and magnetic resonance images revealed paravertebral and epidural extension of mass in L1 vertebra. After thyroidectomy, histopathological study showed a follicular carcinoma. We performed L1 total en bloc spondylectomy with expandable cage for long-term local control. The technical details of total en bloc spondylectomy in follicular carcinoma are described herein.

A Comparative Study of the Effects of Gibbs Smoothing Priors in Bayesian Tomographic Reconstruction (Bayesian Tomographic 재구성에 있어서 Gibbs Smoothing Priors의 효과에 대한 비교연구)

  • Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.279-282
    • /
    • 1997
  • Bayesian reconstruction methods for emission computed tomography have been a topic of interest in recent years, partly because they allow for the introduction of prior information into the reconstruction problem. Early formulations incorporated priors that imposed simple spatial smoothness constraints on the underlying object using Gibbs priors in the form of four-nearest or eight-nearest neighbors. While these types of priors, known as "membrane" priors, are useful as stabilizers in otherwise unstable ML-EM reconstructions, more sophisticated prior models are needed to model underlying source distributions more accurately. In this work, we investigate whether the "thin plate" model has advantages over the simple Gibbs smoothing priors mentioned above. To test and compare quantitative performance of the reconstruction algorithms, we use Monte Carlo noise trials and calculate bias and variance images of reconstruction estimates. The conclusion is that the thin plate prior outperforms the membrane prior in terms of bias and variance.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

Quality Assurance and Performance Evaluation of PET/CT (핵의학 영상장비 PET/CT의 정도관리와 성능평가)

  • Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.137-144
    • /
    • 2008
  • Positron emission tomography-computed tomography (PET/CT) provides both functional and anatomical images of high quality non-invasively with better precision in localization than PET alone. Increase in the use of PET/CT, coupled with increasing concerns about the quality of medical services accrued the demands for accurate evaluation of system performance and quality assurance. Thus, well designed programs for performance evaluation and quality assurance are needed. Widely used protocols for performance evaluation of PET are the methods proposed by National Electrical Manufacturers Association (NEMA) in 1994 and 2001. In addition, in order to maintain high quality of PET/CT images, quality assurance programs including periodic (daily, monthly, and yearly). Therefore, in this article, the methods and present state of performance evaluation and quality assurance of PET/CT are reviewed.

Interband optical properties in wide band gap group-III nitride quantum dots

  • Bala, K. Jaya;Peter, A. John
    • Advances in nano research
    • /
    • v.3 no.1
    • /
    • pp.13-27
    • /
    • 2015
  • Size dependent emission properties and the interband optical transition energies in group-III nitride based quantum dots are investigated taking into account the geometrical confinement. Exciton binding energy and the optical transition energy in $Ga_{0.9}In_{0.1}N$/GaN and $Al_{0.395}In_{0.605}N$/AlN quantum dots are studied. The largest intersubband transition energies of electron and heavy hole with the consideration of geometrical confinement are brought out. The interband optical transition energies in the quantum dots are studied. The exciton oscillator strength as a function of dot radius in the quantum dots is computed. The interband optical absorption coefficients in GaInN/GaN and AlInN/AlN quantum dots, for the constant radius, are investigated. The result shows that the largest intersubband energy of 41% (10%) enhancement has been observed when the size of the dot radius is reduced from $50{\AA}$ to $25{\AA}$ of $Ga_{0.9}In_{0.1}N$/GaN ($Al_{0.395}In_{0.605}N$/AlN) quantum dot.

Numerical Analyses of Fuel Sprays in a Constant Volume Chamber (정적챔버내 연료분무의 수치해석적 연구)

  • Yang, Du-Han;Park, Hyung-Koo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.974-979
    • /
    • 2003
  • This study aimed to analyze spray characteristics and the ambient flow field in the mixture preparation state of the premixed combustion stage. It is very important to understand the spray characteristics and the fuel injection conditions in direct injection diesel engine because the emission gas compositions from diesel engines are related to spray formation processes of the premixed combustion stage. The numerical simulation was performed using the STAR-CD which is a commercial CFD code. Computed results of the transient high pressure diesel spray were compared with experimental results of the same spray injection condition in the constant volume chamber. The results show that spray patterns of numerical simulation agree with this experimental results comparatively.

  • PDF