• 제목/요약/키워드: emission computed

검색결과 456건 처리시간 0.027초

18F-2-Deoxy-2-Fluoro-D-Glucose Positron Emission Tomography: Computed Tomography for Preoperative Staging in Gastric Cancer Patients

  • Youn, Seok Hwa;Seo, Kyung Won;Lee, Sang Ho;Shin, Yeon Myung;Yoon, Ki Young
    • Journal of Gastric Cancer
    • /
    • 제12권3호
    • /
    • pp.179-186
    • /
    • 2012
  • Purpose: The use of 18F-2-deoxy-2-fluoro-D-glucose positron emission tomography-computed tomography as a routine preoperative modality is increasing for gastric cancer despite controversy with its usefulness in preoperative staging. In this study we aimed to determine the usefulness of preoperative positron emission tomography-computed tomography scans for staging of gastric cancer. Materials and Methods: We retrospectively analyzed 396 patients' positron emission tomography-computed tomography scans acquired for preoperative staging from January to December 2009. Results: The sensitivity of positron emission tomography-computed tomography for detecting early gastric cancer was 20.7% and it was 74.2% for advanced gastric cancer. The size of the primary tumor was correlated with sensitivity, and there was a positive correlation between T stage and sensitivity. For regional lymph node metastasis, the sensitivity and specificity of the positron emission tomography-computed tomography were 30.7% and 94.7%, respectively. There was no correlation between T stage and maximum standardized uptake value or between tumor markers and maximum standardized uptake value. Fluorodeoxyglucose uptake was detected by positron emission tomography-computed tomography in 24 lesions other than the primary tumors. Among them, nine cases were found to be malignant, including double primary cancers and metastatic cancers. Only two cases were detected purely by positron emission tomography-computed tomography. Conclusions: Positron emission tomography-computed tomography could be useful in detecting metastasis or another primary cancer for preoperative staging in gastric cancer patients, but not for T or N staging. More prospective studies are needed to determine whether positron emission tomography-computed tomography scans should be considered a routine preoperative imaging modality.

F-18 fluorodeoxyglucose positron emission tomography/computed tomography in the infection of heart

  • Kong, Eunjung
    • Journal of Yeungnam Medical Science
    • /
    • 제38권2호
    • /
    • pp.95-106
    • /
    • 2021
  • Infections involving the heart are becoming increasingly common, and a timely diagnosis of utmost importance, despite its challenges. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is a recently introduced diagnostic tool in cardiology. This review focuses on the current evidence for the use of FDG PET/CT in the diagnosis of infective endocarditis, cardiac implantable device infection, left ventricular assist device infection, and secondary complications. The author discusses considerations when using FDG PET/CT in routine clinical practice, patient preparation for reducing physiologic myocardial uptake, acquisition of images, and interpretation of PET/CT findings. This review also functions to highlight the need for a standardized acquisition protocol.

Preclinical evaluation using functional SPECT imaging of 123I-metaiodobenzylguanidine (mIBG) for adrenal medulla in normal mice

  • Yiseul Choi;Hye Kyung Chung;Sang Keun Woo;Kyo Chul Lee;Seowon Kang;Seowon Kang;Joo Hyun Kang;Iljung Lee
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.93-98
    • /
    • 2021
  • meta-iodobenzylguanidine is one of the norepinephrine analogs and reuptakes together with norepinephrine with norepinephrine transporter. The radioiodinated ligand, 123I-meta-iodobenzylguanidine, is the most widely used for single photon emission computed tomography imaging to diagnose functional abnormalities and tumors of the sympathetic nervous system. In this study, we performed cellular uptake studies of 123I-meta-iodobenzylguanidine in positive- and negative-norepinephrine transporter cells in vitro to verify the uptake activity for norepinephrine transporter. After 123I-meta-iodobenzylguanidine was injected via a tail vein into normal mice, Single photon emission computed tomography/computed tomography images were acquired at 1 h, 4 h, and 24 h post-injection, and quantified the distribution in each organ including the adrenal medulla as a norepinephrine transporter expressing organ. In vitro cell study showed that 123I-meta-iodobenzylguanidine specifically uptaked via norepinephrine transporter, and significant uptake of 123I-meta-iodobenzylguanidine in the adrenal medulla in vivo single photon emission computed tomography images. These results demonstrated that single photon emission computed tomography imaging with 123I-meta-iodobenzylguanidine were able to quantify the biodistribution in vivo in the adrenal medulla in normal mice.

근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성 (The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography)

  • 신덕섭;나호동;박재우
    • 대한정형외과학회지
    • /
    • 제54권6호
    • /
    • pp.509-518
    • /
    • 2019
  • 목적: 악성 종양 환자에서 림프절 전이를 발견하는 것은 초기에 정확한 병기 및 예후와 관련된 정보를 알 수 있고 수술 후 보조치료(adjuvant therapy)의 필요성을 평가해서 조기에 치료를 할 수 있도록 해주기 때문에 중요하다. 본 연구를 통해 정형외과 영역의 악성 종양 환자를 평가함에 있어 양전자 방출 컴퓨터 단층 촬영기(positron emission tomography/computed tomography, PET/CT)가 sentinel lymph node biopsy와 비교하여 유용한지를 알아보고자 한다. 대상 및 방법: 2008년부터 2018년까지 악성 근골격계 종양으로 진단받고 PET/CT를 촬영한 환자 251명 중 72명의 환자를 선별하여 후향적 분석을 시행하였다. 림프절 전이가 의심되는 환자군은 조직검사를 시행하였다. 분석은 의무기록, 임상정보, PET/CT 영상 및 판독 소견, 병리 결과를 통해 시행하였으며, 임상경과 및 병리검사 결과를 PET/CT 결과와 비교하여 PET/CT의 정확도를 평가하였다. 결과: 환자의 나이는 14세에서 88세까지 분포하였고, 평균 추시 기간은 2.4년이었으며, 22명에서 림프절의 전이가 확인되었다. 육종 및 비육종 종양에서 PET/CT 영상의 민감도, 특이도, 양성예측도, 음성예측도는 전문가의 소견을 함께 고려할 경우 상당히 상승하는 것을 확인하였다. 결론: 본 연구를 통하여 전문가의 소견을 함께 고려한다면, 림프절의 전이를 발견하는 데 PET/CT의 유용성은 증가할 것으로 생각된다.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Framework to Compute Vehicle Emission Costs Associated with Work Zones

  • Shrestha, K. Joseph;Adebiyi, Jeremiah;Uddin, Mohammad Moin;Sturgill, Roy
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.952-959
    • /
    • 2022
  • Active construction work zones will result in longer travel time and/or longer travel distances for road users because of reduced speed limits and/or detours. This results in increased fuel consumption and increased emissions of harmful gases such as Carbon Monoxide (CO), Nitrogen Oxides (NOx), and Sulfur Oxides (SOx), which causes discomfort to the environment and road users around the work zone. The impact of such emissions should be considered while designing work zones or determining the number of days the roadway will be allowed to be closed partially or fully. This study develops a methodology to compute additional road user costs associated with such work zones. To achieve this goal, a) an extensive literature review is conducted, b) a framework to compute emission cost is developed, c) emission rates are computed for all counties (95) of the state of Tennessee, and d) a case study is conducted to demonstrate the use of the framework to estimate the additional impact of emission because of the work zone. For the case study conducted, the emission cost was computed to be $10,653.60 for the duration of the project. State DOTs can account for such road user costs while selecting contractors using A+B bidding. Accounting for such impact of emission will also indicate the agency's willingness to consider sustainability as a part of the business practices.

  • PDF

단일광자방출 전산화단층촬영상에서 재구성 필터에 의한 정량화 오차에 관한 연구 (A Study on the Quantification Error due to the Reconstruction Filters in Single Photon Emission Computed Tomography(SPECT))

  • 곽철은;정준기
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권1호
    • /
    • pp.43-48
    • /
    • 1991
  • As the computerized methods and equipments In nuclear medicine imaging increases, quantitative information is needed on the single photon emission computed tomographic Images as well as on the conventional nuclear medicine images. In this paper, the authors investigated the effect of several clinician - friendly reconstrution filters on the resultant transverse slices of backprojected Profiles of radioisotope distribution from the Quantitative point of view, and reduced the filter parameters such as cutoff frequency and order of filter which are neces mary to minimize the quantification error using computer-generated phantoms.

  • PDF

한반도 상공 고층대기의 중간 자외선 대기광 모델 (A MODEL FOR MUV AIRGLOW FROM THE UPPER ATOMOSPHERE ABOVE THE KOREAN PENINSULA)

  • 문봉곤;김용하;이유;김준
    • 천문학회지
    • /
    • 제34권1호
    • /
    • pp.35-40
    • /
    • 2001
  • For the planned experiments of Korea Sounding Rocket-III (KSR-III), we have constructed a model of MUV dayglow in the mid-latitude. The model computes relative intensities of individual emission lines in the Vegard-Kaplan and 2PG band systems of $N_2$ in the wavelength range of 2500-3500${\AA}$. In addition to the emission lines, solar scattered continuum was computed by an extended LOWTRAN7 code, in which we have included solar scattering in altitudes higher than 100 km by using MSIS90 thermosphere model. Ratios among vibrational bands of VK and 2PG system, were computed from the observed MUV dayglow spectra of Cleary et al. (1995). The model provides MUV dayglow intensitiy profiles with a wavelength resolution of 3.13${\AA}$ as a function of altitude. The computed intensity profiles have been utilized in designing the KSR-III airglow photometers.

  • PDF

Improvement of signal and noise performance using single image super-resolution based on deep learning in single photon-emission computed tomography imaging system

  • Kim, Kyuseok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2341-2347
    • /
    • 2021
  • Because single-photon emission computed tomography (SPECT) is one of the widely used nuclear medicine imaging systems, it is extremely important to acquire high-quality images for diagnosis. In this study, we designed a super-resolution (SR) technique using dense block-based deep convolutional neural network (CNN) and evaluated the algorithm on real SPECT phantom images. To acquire the phantom images, a real SPECT system using a99mTc source and two physical phantoms was used. To confirm the image quality, the noise properties and visual quality metric evaluation parameters were calculated. The results demonstrate that our proposed method delivers a more valid SR improvement by using dense block-based deep CNNs as compared to conventional reconstruction techniques. In particular, when the proposed method was used, the quantitative performance was improved from 1.2 to 5.0 times compared to the result of using the conventional iterative reconstruction. Here, we confirmed the effects on the image quality of the resulting SR image, and our proposed technique was shown to be effective for nuclear medicine imaging.