• Title/Summary/Keyword: emergency operation

Search Result 936, Processing Time 0.029 seconds

A Selection Method of Implementation Area for Emergency Vehicle Preemption System Using Dispatch Data Analysis (출동현황자료 분석을 통한 재난대비 긴급차량 우선신호제어 시스템 도입지역 선정방안 연구)

  • Sung, Joong Gi;Ha, Dongik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.24-35
    • /
    • 2016
  • Emergency Vehicle Preemption(EVP) is an operation method which helps to improve response condition of Emergency Vehicle(EV) and it has not yet been introduced in Korea. In order to implement the system, it requires step-by-step plan and selecting a priority area for trial operation. Since a municipal government such as Seoul is too large so it is limited in time and cost to analyze the whole area. Therefore, quantitative and effective selection method for priority area is critical. The aim of this study is to propose a selection method of implementation area for EVP system using the dispatch data analysis. This study also determined the priority area for EVP implementation by analyzing the dispatch data in Seoul and conducted a simulation to evaluate the effects of implementing EVP.

A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.

Using nasal cannula for sevoflurane deep sedation in emergency dental treatment

  • Kim, Jongbin;Yoo, Seunghoon;Kim, Jongsoo;Kim, Seungoh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.1
    • /
    • pp.11-15
    • /
    • 2015
  • Background: Emergency room doctors run into difficulties in treating injured pediatric patients because usually they fell into panic after trauma. In these situation, deep sedation with sevoflurane is fully recommendable method. The conventional way can interrupt common dental treatment procedure. Methods: In the present study, nasal cannula was used for sevoflurane deep sedation in 11 dental emergency treatment. Age ranged from 0 to 3 years old (average of 1.8 years). Results: Treatment duration was from 10 to 35 minutes (average of 16.7 minutes). Average duration of sedation was 25.5 minutes ranging from 15 to 45 minutes. Conclusions: It has advantages to use nasal cannula for sevoflurane deep sedation rather than conventional intubation; saves time and secures good operation field.

A Study on the Optimum Design Parameters for Robot Teach Pendant (로보트 안전사고 방지를 위한 비상 정지 스위치의 설계지침에 관한 연구)

  • Park, Se-Jin;Lee, Nahm-Sik;Kim, Chul-Jung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.16 no.2
    • /
    • pp.99-107
    • /
    • 1990
  • Many accidents related to robot operation occur during the robot teaching process. This paper deals with recommendations for the teach pendant design parameters to enhance safety and performances in human-robot interactions. In order to investigate the optimum location and the size of the emergency stop button on the teach pendant, an experiment was conducted with a simulated teach pendant which can accomodate four different locations and three sizes of the button. Under a simulated emergency condition, the reach time to the emergency stop button was measured at random combination of the location and the size of button. The reach time was significantly affected by the location and the size of the emergency stop button. The fastest average reach time was attained with 1.5 inch-diameter button on the upper center of the teach pendant.

  • PDF

A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection (비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구)

  • Kim, Kyung-Chul;Kho, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시 기술 적용 연구)

  • Choi, K.H.;Park, J.H.;Park, J.E.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

An analysis of the state of operation of the electrical safety emergency dispatch system (전기안전 긴급출동제도 운영 실태 분석)

  • Yoo, Jae-Geun;Kim, Jae-Hyun;Lee, Ki-Sik;Koo, Kyung-Wan;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1748-1751
    • /
    • 2012
  • This paper describes the background of the electrical safety emergency dispatch system and analyzes the operational status of the system. This system is to provide the enhanced electrical safety service to general-purpose electrical equipment users. Annual average of about 6 million cases have been implemented since 2005. In order to enhance electrical safety service and more effectively prevent electrical disasters in future, institutional expansion of the electrical safety emergency dispatch system with keeping budget is necessary. If periodic inspections with a remote monitoring system is applied, the effect of electrical safety will be improved.

HUMAN-MACHINE INTERACTION IN NUCLEAR POWER PLANTS

  • YOSHIKAWA HIDEKAZU
    • Nuclear Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.151-158
    • /
    • 2005
  • Advanced nuclear power plants are generally large complex systems automated by computers. Whenever a rare plant emergency occurs the plant operators must cope with the emergency under severe mental stress without committing any fatal errors. Furthermore, The operators must train to improve and maintain their ability to cope with every conceivable situation, though it is almost impossible to be fully prepared for an infinite variety of situations. In view of the limited capability of operators in emergency situations, there has been a new approach to preventing the human error caused by improper human-machine interaction. The new approach has been triggered by the introduction of advanced information systems that help operators recognize and counteract plant emergencies. In this paper, the adverse effect of automation in human-machine systems is explained. The discussion then focuses on how to configure a joint human-machine system for ideal human-machine interaction. Finally, there is a new proposal on how to organize technologies that recognize the different states of such a joint human-machine system.

Enhancement Plan for Overall Disaster Prevention System

  • Moon, Sang-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.1
    • /
    • pp.6-10
    • /
    • 2011
  • In Korea, overall disaster prevention system or 119 emergency rescue system has been established to protect life and fortune of citizens. This system supports command & control operation, emergency 119 caller location indicator, automatic formation of fire troops and dispatch, and emergency management. To do this, various new information technologies such as GIS, telematics, CTI and TTS are applied to implement the system. In the future, however, it is not impossible to prevent a large scale disasters caused by world climate environment change and complication of city culture using the current system. In this paper, we propose enhancement plan for overall disaster prevention system to solve this problem.

A Study on the Emergency Power of the Airport with the case study (사례연구를 통한 공항의 비상전원에 관한 연구)

  • Choi, Hong-Kyu;Choi, Young-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.129-133
    • /
    • 2005
  • While everyone who uses electric power desires perfect frequency, voltage, stability, and reliability at all times, this cannot be realized in practice. The supplying utility cannot be expected to provide a perfect power supply because many of the causes of power supply disturbances are beyond the control of the utility. The outage happens but due to many reason. The electricity equipment requires consequently the emergency power supply. We classify the subordinate for quick supply of the emergency power supply and must grope the supply plan. We will find out in this paper through the case study about the emergency power efficient operation plan.

  • PDF