• Title/Summary/Keyword: elevator prevention

Search Result 22, Processing Time 0.028 seconds

Accident Prevention Counterplen of the Elevator for the Passenger (승객용 승강기의 재해예방에 관한 연구)

  • Kwon, Oh-Heon;Go, Seong-Seok;Yun, Yu-Seong
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.106-111
    • /
    • 2002
  • Recently the car and elevator accidents as well as the fire, explosion and collapse increased. The passenger elevator accident from 1993 year to 2001 year has about 56.7% of total accidents and the human victims of 180 according to the Korea Elevator Safety Institute. Accident cause and prevention were investigated for the elevator having the fall, impact and narrowness accident types. The prevention and protection methods of the elevator accident from analysis results were suggested by comparing and analogizing the accident statistics about the accident investigation of the passenger elevator according to the elevator accidents.

The vibration quality analysis for the vibration prevention of the building elevator (건축물(建築物) Elevator의 방진(防振)을 위한 진동특성(振動特性) 분석(分析))

  • Jeon, Euy-Sik;Cho, Byoung-Hoo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.5 no.2
    • /
    • pp.29-35
    • /
    • 2005
  • The interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the vibration which occurs from the elevator cage of the building is possibility of damage to the users of the building continuously. So, the purpose of this study is a place where it examines closely the vibrating unit of the elevator and propose the countermeasure of it.

  • PDF

Safety Management Improvement Plan for Elevator Worker Safety Accident Prevention (승강기작업자 안전사고예방을 위한 안전관리 개선 방안)

  • Kim, Beom-Sang;Park, Poem
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.23-29
    • /
    • 2020
  • Korea's elevator industry is one of the world's eighth-largest industrial sectors and the third largest in the world by new installations. This year, the number of elevators has exceeded 700,000, and the number of new installations is 30,000-40,000 every year. However, the news of elevator-related accidents is reported continuously through the media and the accident rate is not decreasing. In particular, among the recent accidents related to elevators, accidents related to elevator workers are increasing, causing social problems. This year, the National Assembly's Environmental Labor Relations Commission's National Auditors lost five lives a year and 12 elevator workers were killed in fall and stenosis accidents during the installation, maintenance and replacement of the elevators for about two years since 2018. It took place to adopt the representatives of four domestic elevator companies as witnesses. An elevator worker is a collective term for workers involved in the design, manufacturing, installation, replacement, maintenance, inspection, management, and supervision related to the elevator industry, and the related accidents are called elevator worker accidents. Analysis of elevator-related accidents in the past has shown that the fault of the user accounted for 70% of the total, and the fault of the worker accounted for about 2.5%, and the accident occurred to the user or the user due to carelessness of the worker during the lift-related work. Currently, elevator-related accidents are reported by the Korea Elevator Safety Agency under Article 48 of the Elevator Safety Management Act under the Ministry of Interior and Safety. If deemed necessary for the prevention and prevention of recurrence of an elevator accident, the cause and condition of the elevator accident may be investigated. However, the current draft law is limited only to elevators after installation inspection, and is separated from the Ministry of Employment and Labor's data on accidents occurring in the manufacturing and installation stages related to the elevator industry. This study analyzes the recent safety accidents of elevator workers and prepares safety measures to prevent them through the risk analysis, and also draws out the problems and improvements of the current elevator worker accident investigation to find the elevator worker accident rate that is on the increase trend.

A Study on the Estimation of the Optimum Lifetime of Elevator Components for Elevator Accident Prevention (엘리베이터 사고예방을 위한 승강기 부품의 최적 수명 추정에 관한 연구)

  • Kim, Han-jin;Hwang, Min-soo;Choi, Og-man;Lee, An-ki;Kim, Jae-chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1278-1284
    • /
    • 2017
  • As of December 2016, there are 608,828 elevators in operation in Korea and 179,790 elevators in more than 15 years. 30.4% of all elevator are aging. Improved maintenance of the elevator and proactive replacement of the parts of the elevator can extend the lifetime of the elevator and ensure safety. An unclean environment reduces the lifetime of elevator parts. If you do not clean the environment and prevent preventive parts replacement, eventually shortening the lifetime of the parts connected to the failed part or causing more damage will result in greater economic loss. Also, the risk of elevator safety accidents due to failures of elevator parts will be increased accordingly. The study of optimum replacement time of elevator parts will contribute to prevention of safety accident of elevator and prolongation of lifetime of elevator through preventive replacement of elevator parts.

Accident Prevention for the Elevator and Escalator by the Accident Type Analysis (사고유형 분석에 의한 승강기 및 에스컬레이터 재해예방)

  • Jeong, Ok Nam;Yun, Yu Seong;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.15-21
    • /
    • 2016
  • The elevator is an essential part of the transportation means in modern society. It has become the convenient movement means of vertical and horizontal mobilities for vulnerable citizens including the disabled or elderly in skyscrapers and the multi-purposes facilities. After the 1990s, the number of newly installed elevators have increased because of the establishment of large scale public houses which need an increase of means of transportation. Thus, the safety accident in the elevator has been currently in an increasing trend as years passed by because that the elevator is always exposed to the risk of accident. Most of the elevator accidents occur in the escalator and moving walkway. This study investigated the current usage situations of users at multi-purpose shopping spaces, the sub way, and the airport about the escalator including moving walkway. Moreover the accident types were analyzed for the escalator based on 10 years of statistics. And the methods for the accident prevention were proposed on the equipment, management and user side.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

A Study on electrical equipment effect of apartment customer elevator by power quality (전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구)

  • Lee, Hee-Tae;Kim, Jae-Chul;Kang, Jang-Gyou;Kim, Gi-Hyun;Seoul, Kyu-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

A Study on the Pressure Change during the Pressurization to the Elevator Lobby (부속실 급기가압 시 압력특성 변화에 관한 연구)

  • Kim, Beom-Kyue;Park, Yong-Hwan;Kim, Hong-Sik
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2012
  • This study investigated the pressure change in the fire room and elevator lobby during the air pressurization to the Elevator lobby with the various egress scenarios and the existence of vent holes in the fire room. The experiments revealed that pressure change was significantly affected by the open/closure scenarios of the front door and stairway door resulting in over pressure, under pressure and performance drop of the door closure. It also revealed that the required smoke defensive air velocity can be obtained only with the existence of vent holes in the fire room by the removal of back pressure in the fire room.

The Comparative Study on Safety Factors at Elevator Management System Operation (승강기 관리시스템 운영 시 안전요소에 관한 비교연구)

  • Park, Joo-Bong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.159-162
    • /
    • 2014
  • Recently, from 2008 to 2012, there are many of elevator safety patents from patent office survey. In this paper, we analyzed the elevator safety patent from 2009 to 2013, found out safety factor is safety control, emergency stop equipment and door opening equipment. Through reliability statistics, we defined the most important things for safety elevator factor is this three things, studied the reason about many patents. Finally, we propose the Kinect Scada elevator system for prevention safety accident.