• Title/Summary/Keyword: electroosmotic flow

Search Result 67, Processing Time 0.02 seconds

Electroosmotic Flows in Microfluidic Chips

  • Yang R.-J.;Fu L.-M.;Lee G.-B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.123-125
    • /
    • 2003
  • Understanding the physics of electroosmotic flow is important to the optimum design and operation of microfluidic systems. Recent development on the topic in our group is summarized in this presentation. Applications to the variable-volume-Injection, micro flow switch, electrokinetic focusing, and flow cytometer will be presented with our novel design and control.

  • PDF

Asymmetric Flows for Porous Silicon Electroosmotic Pumps (다공성 실리콘막을 포함한 전기침투 방식 펌프에서의 비대칭적 인 유동)

  • Kim, Dae-Joong;Santiago, Juan G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.703-704
    • /
    • 2008
  • We fabricated and tested porous silicon-based electroosmotic pumps. Compared to other pumping media, porous silicon is beneficial for obtaining comparable flow rates with much lowered electric potential, while maintaining enough mechanical properties. We fabricated porous silicon with two sided-reactive etching processes. We found higher flow rate per electric potential (consistent with previous studies) and we also found asymmetric flow rates for different pumping directions. We plan to utilize this asymmetry for AC pumping applications.

  • PDF

Electroosmosis in skin during iontophoresis: effect of pH, current density and ionic strength

  • Kim, Su-Youn;Kang, Rae-Young;Kim, Hye-Ji;Roh, Kyung-Eun;Oh, Seaung-Youl
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.294.1-294.1
    • /
    • 2003
  • At pH 7.4 (physiological pH), skin is permselective to cations, due to the net negative charge of the current passing channels (pores) in skin. This causes the convective solvent flow (electroosmotic flow) from anode to cathodal direction. In this work, we have investigated several factors (pH. current density and ionic strength) that can affect the electroosmotic flow. (omitted)

  • PDF

Porous Glass Electroosmotic Pumps Reduced Bubble Generation Using Reversible Redox Solutions (가역적 산화환원반응 용액을 이용하여 기포 발생을 줄인 다공성 유리막 전기삼투 펌프)

  • Kwon, Kil-Sung;Kim, Dae-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.753-757
    • /
    • 2012
  • This paper presents the performance of a porous glass electroosmotic pump using an iodide/triiodide aqueous solution. The porous glass electroosmotic pump is characterized in terms of the flow rate and voltage. The flow rate and voltage increases linearly with current. A point where the voltage significantly increases is observed owing to an excess in redox capacity. The transition time monotonously decreases with current. The normalized flow rate (flow rate per membrane surface area) is used to compare previous results with results obtained in this study. The normalized flow rate of porous glass frits is three times higher than that of Nafion 117.

A STUDY ON CHARACTERISTICS OF AC ELECTROOSMOTIC FLOWS AND MIXING IN A MICROCHANNEL WITH COPLANAR ELECTRODES (마이크로 채널 내 교류 전기삼투 현상을 이용한 유체 유동 및 혼합에 대한 수치해석적 연구)

  • Suh, Y.K.;Heo, H.S.
    • Journal of computational fluids engineering
    • /
    • v.12 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • This paper presents numerical results of fluid flows and mixing in a microfluidic device with AC electroosmotic flows (AC-EOF) around coplanar electrodes attached on the top and bottom walls. To obtain the flow and mixing characteristics, numerical computations are performed by using a commercial code, CFX10. Experiment was performed to confirm the generation of the drift velocity around the electrodes. It was found that near the coplanar electrodes 3-D complex flows are generated. The AC-electroosmotic flow on the electrodes plays an important role in mixing the liquid.

AC-Electroosmotic Flows-Fundamental Mechanism and Kinematic Aspects (교류 전기삼투유동 - 근본 메커니즘과 운동학적 양상)

  • Suh, Yonk-Kweon
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.3-16
    • /
    • 2008
  • Controlling fluid flows in micro scales is a non-trivial issue among those who are involved in designing lab-on-chips. Pumping and mixing by using electrokinetic principles has been popular in that the method requires a few parts and it is easy to control. This paper explains the basic mechanism of the electroosmotic flows caused by AC together with presenting some numerical results. In particular, the fundamental, physical idea involved in the mechanism will be illustrated in terms of the kinematic aspect. Since the electroosmotic flows are mainly driven by the motion of ions, we also demonstrate the ion motions by using the numerical-visualization method.

Modulation of Electroosmotic Flow through Skin: Effect of Poly(Amidoamine) Dendrimers

  • Kim, Hye Ji;Oh, Seaung Youl
    • Biomolecules & Therapeutics
    • /
    • v.26 no.2
    • /
    • pp.182-190
    • /
    • 2018
  • The objective of this work is to evaluate the effect of polyamidoamine (PAMAM) dendrimers on electroosmotic flow (EOF) through skin. The effect of size and concentration of dendrimer was studied, using generation 1, 4 and 7 dendrimer (G1, G4 and G7, respectively). As a marker molecule for the direction and magnitude of EOF, a neutral molecule, acetoaminophen (AAP) was used. The visualization of dendrimer permeation into the current conducting pore (CCP) of skin was made using G4-fluorescein isothiocyanate (FITC) conjugate and confocal microscopy. Without dendrimer, anodal flux of AAP was much higher than cathodal or passive flux. When G1 dendrimer was added, anodal flux decreased, presumably due to the decrease in EOF by the association of G1 dendrimer with net negative charge in CCP. As the generation increased, larger decrease in anodal flux was observed, and the direction of EOF was reversed. Small amount of methanol used for the preparation of dendrimer solution also contributed to the decrease in anodal flux of AAP. Cross-sectional view perpendicular to the skin surface by confocal laser scanning microscope (CLSM) study showed that G4 dendrimer-FITC conjugate (G4-FITC) can penetrate into the viable epidermis and dermis under anodal current. The permeation route seemed to be localized on hair follicle region. These results suggest that PAMAM dendrimers can permeate into CCP and change the magnitude and direction of EOF. Overall, we obtained a better understanding on the mechanistic insights into the electroosmosis phenomena and its role on flux during iontophoresis.

Electrokinetic remediation of diesel-contaminated silty sand under continuous and periodic voltage application

  • Asadollahfardi, Gholamreza;Rezaee, Milad
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.456-462
    • /
    • 2019
  • Hydrocarbon contamination is among the most challenging problems in soil remediation. Electrokinetic method can be a promising method to remediate hydrocarbon-contaminated soils. Electrokinetic method consists of different transport phenomena including electro-migration, electrophoresis, and electroosmotic flow. Electroosmotic flow is the main transport phenomenon for hydrocarbon removal in soil porous media. However, the main component of hydrocarbons is the hydrophobic organic which indicates low water solubility; therefore, it makes the electroosmotic flow less effective. The objective of the present study is to enhance electrokinetic remediation of diesel-contaminated silty sand by increasing the solubility of the hydrocarbons in the soil and then increase the efficiency. For this purpose, sodium dodecyl sulfate (SDS) was used as a catholyte. In this content, SDS 0.05 M was used as catholyte and $Na_2SO_4$ 0.1 M was used as an anolyte. Low (1 V/cm) and high (2 V/cm) voltage gradients were used in periodic and continuous forms. The best removal efficiency was observed for high voltage gradient (2 V/cm) in a periodic form, which was 63.86. This result showed that a combination of periodic voltage application in addition to the employment of SDS is an effective method for hydrocarbon removal from low permeable sand.

Electrokinetic-Fenton 기법에 의한 phenanthrene으로 오염된 토양의 처리

  • 김정환;김강호;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.51-54
    • /
    • 2001
  • This research was carried out to evaluate feasibility of using an Electrokinetic-Fenton(EK-Fenton) technique to treat hydrophobic organic pollutant(phenanthrene) from soils. Experiment examined the effect by introducing a continuous flow of a 3.5% hydrogen peroxide solution at the anode. An electric gradient of 1V/cm was applied to enhance the saturated flow in the soil cell for a period of 11 days. After 11 days or 1 pore volume, overall concentration of residual phenanthrene in the soil cell was 11% and residual phenanathrene concentration in the soil was found to increase with toward the cathode. This results indicated that Fenton-like reaction catalyzed by mineral surface was effective in oxidizing phenanthrene. This results also showed that hydrogen peroxide was effectively transported into the soil by electroosmotic flow as well as by diffusion.

  • PDF

A STUDY ON CHARACTERISTICS OF Ac ELECTRO-OSMOTIC FLOWS IN THE MICROCHANNEL WITH COPLANAR ELECTRODES (마이크로 채널 내 동일 평면 전극에 교류인가로 인한 유동특성 연구)

  • Heo, H.S.;Kang, S.M.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.163-166
    • /
    • 2006
  • This paper presents numerical results of fluid flows and mixing in a microfluidic device for AC electroosmotic flow (AC-EOF) with coplanar electrodes on top and bottom walls. Differently from previous EOF a channel which attached a couple of coplanar electrodes can be utilized to mix a target liquid with a reagent. In this study we propose a method of controlling fluid flows and mixing enhancement. To obtain the flow and mixing characteristics, numerical computations are performed by using a commercial code, CFX10. It was found that the flow near the coplanar electrodes is of 3-D complex flows and vortices between the other electrodes, and as a consequence the AC-electroosmotic flow on the electrodes plays an important role in mixing the liquid.

  • PDF