• Title/Summary/Keyword: electronic eye

Search Result 181, Processing Time 0.028 seconds

Study on Face recognition algorithm using the eye detection (눈 검출을 이용한 얼굴인식 알고리즘에 관한 연구)

  • Park, Byung-Joon;Kim, Ki-young;Kim, Sun-jib
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.491-496
    • /
    • 2015
  • Cloud computing has emerged with promise to decrease the cost of server additional cost and expanding the data storage and ease for computer resource sharing and apply the new technologies. However, Cloud computing also raises many new security concerns due to the new structure of the cloud service models. Therefore, the secure user authentication is required when the user is using cloud computing. This paper, we propose the enhanced AdaBoost algorithm for access cloud security zone. The AdaBoost algorithm despite the disadvantage of not detect a face inclined at least 20, is widely used because of speed and responsibility. In the experimental results confirm that a face inclined at least 20 degrees tilted face was recognized. Using the FEI Face Database that can be used in research to obtain a result of 98% success rate of the algorithm perform. The 2% failed rate is due to eye detection error which is the people wearing glasses in the picture.

Design and manufacture of eyeball protrusion measuring device using white light scanning interferometer (백색광 간섭계를 이용한 안구 돌출 측정 장치 설계 및 제작)

  • Chang, Jung-soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2019
  • The relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure eyeball protrusion values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In this paper, we designed and fabricated a protrusion measuring device using a white light interferometer and measured the protrusion of the human eye and found that the precision and repeatability were significantly higher than the manual measurement method.

A Study of Korean Medicine Hospital Inpatient Consulted by Korean Medicine Ophthalmology, Otolaryngology & Dermatology Department for Ophthalmology Disease (안과 질환으로 한방안이비인후피부과에 의뢰된 한방병원 입원 환자에 대한 고찰)

  • Mi-rae Jeong;Eun-na Heo;Kang Kwon;Hyung-sik Seo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.36 no.4
    • /
    • pp.19-29
    • /
    • 2023
  • Objectives : The purpose of this study is to retrospectively analyze 3 years of inpatient ophthalmology consultation to Korean medicine ophthalmology, otolaryngology & dermatology department in Korean medicine hospital. Methods : We classified ophthalmological inpatient consultations between September 1st, 2019 and August 31st, 2022, based on electronic medical record by gender, age, hospitalized department, categories of diseases. Results : Total number of consultations were 111, and the average of age was 63.6. The proportion of female and male were 2.5:1. Among the 136 cases of eye disease referred, lacriminal production and discharge diseases accounted for the most at 54 cases(39.7%), of which 44 cases were dry eyes syndrome. Excluding dry eye syndrome, conjunctival disease occurred the most with 24 cases(17.6%). Consultations from department of Korean rehabilitation medicine, and Korean internal medicine were most common, because they have a comparatively large number of inpatients and long hospitalization period. Conclusions : This study identified the frequency of consultation and the disease group with many requests for each department. When inpatients complain of eye disease, consultation to Korean medicine ophthalmology, otolaryngology & dermatology department should be encouraged as accurate diagnosis and treatment using specialized equipment is possible and can be used for the purpose of progress observation and examination.

Real Time Eye and Gaze Tracking

  • Park Ho Sik;Nam Kee Hwan;Cho Hyeon Seob;Ra Sang Dong;Bae Cheol Soo
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.857-861
    • /
    • 2004
  • This paper describes preliminary results we have obtained in developing a computer vision system based on active IR illumination for real time gaze tracking for interactive graphic display. Unlike most of the existing gaze tracking techniques, which often require assuming a static head to work well and require a cumbersome calibration process for each person, our gaze tracker can perform robust and accurate gaze estimation without calibration and under rather significant head movement. This is made possible by a new gaze calibration procedure that identifies the mapping from pupil parameters to screen coordinates using the Generalized Regression Neural Networks (GRNN). With GRNN, the mapping does not have to be an analytical function and head movement is explicitly accounted for by the gaze mapping function. Furthermore, the mapping function can generalize to other individuals not used in the training. The effectiveness of our gaze tracker is demonstrated by preliminary experiments that involve gaze-contingent interactive graphic display.

  • PDF

Synthesis, characterization, and toxicity of multi-walled carbon nanotubes functionalized with 4-hydroxyquinazoline

  • Tahermansouri, Hasan;Mirosanloo, Atieh;Keshel, Saeed Heidari;Gardaneh, Mossa
    • Carbon letters
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2016
  • The attachment of 2-aminobenzamide to carboxylated multi-wall carbon nanotubes (MWCNTs)-COOH was achieved through the formation of amide bonds. Then, the functionalized MWCNTs, MWCNT-amide, were treated by phosphoryl chloride to produce MWCNT-quin. The products were characterized by Fourier transform infrared spectroscopy, Raman spectroscopy, scanning electron microscopy, thermogravimetric analysis, derivative thermogravimetric, steady-state fluorescence spectroscopy, and solubility testing. MWCNT-quin showed photo-electronic properties, which is due to the attachment of the 4-hydroxyquinazoline groups to them as proved by steady-state fluorescence spectroscopy. This suggests intramolecular interactions between the tubes and the attached 4-hydroxyquinazoline. The toxicity of the samples was evaluated in human embryonic kidney HEK293 and human breast cancer SKBR3 cell lines, and the viable cell numbers were measured by 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyltetrazolium bromide (MTT) after the cells were cultured for 24 h. Cellular investigations showed that the modified MWCNTs, particularly MWCNT-quin, have considerably significant toxic impact on SKBR3 as compared to HEK293 at the concentration of 5 µg/mL.

Real Time Discrimination of 3 Dimensional Face Pose (실시간 3차원 얼굴 방향 식별)

  • Kim, Tae-Woo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • In this paper, we introduce a new approach for real-time 3D face pose discrimination based on active IR illumination from a monocular view of the camera. Under the IR illumination, the pupils appear bright. We develop algorithms for efficient and robust detection and tracking pupils in real time. Based on the geometric distortions of pupils under different face orientations, an eigen eye feature space is built based on training data that captures the relationship between 3D face orientation and the geometric features of the pupils. The 3D face pose for an input query image is subsequently classified using the eigen eye feature space. From the experiment, we obtained the range of results of discrimination from the subjects which close to the camera are from 94,67%, minimum from 100%, maximum.

  • PDF

Factors influencing Video Display Terminal Syndrome in Clinical Nurses (임상간호사의 영상표시단말기 증후군 및 영향요인)

  • Kwon, Yunhee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

A Study on Performance of Optical Duobinary Transmitters for 25Gbps Transmission (25Gbps 광 신호 전송을 위한 광 듀오바이너리 송신기 특성에 관한 연구)

  • Lee, Dong-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.89-94
    • /
    • 2017
  • This paper presents a theoretical study of transmission performance for optical duobinary transmitters employed a Mach-Zehnder modulator. Especially, we have investigated the performance of the various transmitters for transmitting 25Gbps optical duobinary signals at a wavelength of 1550nm without any dispersion compensation methods over single mode fiber. Due to the characteristics of generating their duobinary signals, each transmitter has a distinct optical power spectrum and an eye opening shape. By these, there was a difference in the dispersion tolerance. We could find a suitable transmitter for 25Gbps transmission considering the structure complexities and the restricted conditions with the simulation results.

A 16-channel CMOS Inverter Transimpedance Amplifier Array for 3-D Image Processing of Unmanned Vehicles (무인차량용 3차원 영상처리를 위한 16-채널 CMOS 인버터 트랜스임피던스 증폭기 어레이)

  • Park, Sung Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1730-1736
    • /
    • 2015
  • This paper presents a 16-channel transimpedance amplifier (TIA) array implemented in a standard $0.18-{\mu}m$ CMOS technology for the applications of panoramic scan LADAR (PSL) systems. Since this array is the front-end circuits of the PSL systems to recover three dimensional image for unmanned vehicles, low-noise and high-gain characteristics are necessary. Thus, we propose a voltage-mode inverter TIA (I-TIA) array in this paper, of which measured results demonstrate that each channel of the array achieves $82-dB{\Omega}$ transimpedance gain, 565-MHz bandwidth for 0.5-pF photodiode capacitance, 6.7-pA/sqrt(Hz) noise current spectral density, and 33.8-mW power dissipation from a single 1.8-V supply. The measured eye-diagrams of the array confirm wide and clear eye-openings up to 1.3-Gb/s operations. Also, the optical pulse measurements estimate that the proposed 16-channel TIA array chip can detect signals within 20 meters away from the laser source. The whole chip occupies the area of $5.0{\times}1.1mm^2$ including I/O pads. For comparison, a current-mode 16-channel TIA array is also realized in the same $0.18-{\mu}m$ CMOS technology, which exploits regulated-cascode (RGC) input configuration. Measurements reveal that the I-TIA array achieves superior performance in optical pulse measurements.

3D VISION SYSTEM FOR THE RECOGNITION OF FREE PARKING SITE LOCATION

  • Jung, H.G.;Kim, D.S.;Yoon, P.J.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.3
    • /
    • pp.361-367
    • /
    • 2006
  • This paper describes a novel stereo vision based localization of free parking site, which recognizes the target position of automatic parking system. Pixel structure classification and feature based stereo matching extract the 3D information of parking site in real time. The pixel structure represents intensity configuration around a pixel and the feature based stereo matching uses step-by-step investigation strategy to reduce computational load. This paper considers only parking site divided by marking, which is generally drawn according to relevant standards. Parking site marking is separated by plane surface constraint and is transformed into bird's eye view, on which template matching is performed to determine the location of parking site. Obstacle depth map, which is generated from the disparity of adjacent vehicles, can be used as the guideline of template matching by limiting search range and orientation. Proposed method using both the obstacle depth map and the bird's eye view of parking site marking increases operation speed and robustness to visual noise by effectively limiting search range.