• 제목/요약/키워드: electromagnetic exposure

검색결과 167건 처리시간 0.024초

전자파 세포노출장치 기술 동향 (Technical Trends of In Vitro Exposure System)

  • 이영승;전상봉;최형도
    • 전자통신동향분석
    • /
    • 제37권3호
    • /
    • pp.33-40
    • /
    • 2022
  • Communication technologies are evolving to meet the ever-increasing demand for fast transmission speeds and large capacity. However, the introduction of new mobile networks, such as 5G, should be accompanied by changes in corresponding frequency and modulation techniques to enable the commercialization of its services. Hence, investigating the human health effects of electromagnetic exposures used in these new communication systems is crucial. Since in vitro electromagnetic experiments can provide essential information on important mechanisms of exposure effects, this article presents in vitro exposure systems necessary for reliable experiments. Moreover, the fundamental requirements for system implementation and the features of various systems are discussed.

Magnetite-Carbon계 전자파흡수 무기도료의 현장 전자파 저감 성능 평가 (Evaluation of Electromagnetic Shielding Efficiency of Magnetite-Carbon based Inorganic Paint)

  • 박동철;이세현;송태협;심종우;박재명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.141-144
    • /
    • 2004
  • Nowadays, there has been substantial interest in whether there is an association between electromagnetic field exposure and living environment. It is increased the demand that electromagnetic wave environment and its countermeasure. In the present study, we has applied the electromagnetic absorbent inorganic paint of 'I' corporations, and measured electromagnetic waves generated in new apartment before occupancy using the standard field electromagnetic wave generating device we developed. The measurement before occupancy was $100\~131V/m$, but the measurement after occupancy was $6.9\~8.0V/m$ less than 10V/m, the comprehensive electromagnetic wave limit allowed by TCO in Sweden. The implication is that domestic apartment are exposed to extremely poor electromagnetic wave environment. Nevertheless, there have been neither serious efforts to overcome this problem, nor its alternatives and related standards. Therefore, it is necessary to continue research of related fields to establish standards and plans to improve the situation.

  • PDF

PCS 대역 세포실험용 전자파 노출 장치 개발 (Development of A Electromagnetic Exposure System for In Vitro Experiments at PCS Band)

  • 박민영;고채옥;성미진;김정란;백정기
    • 한국전자파학회논문지
    • /
    • 제17권4호
    • /
    • pp.335-340
    • /
    • 2006
  • 본 논문에서는 국내 PCS 대역인 1,762.5 MHz의 세포실험용 전자파 노출 장치를 설계 및 제작하였다. 노출 장치는 도파관의 ${\lambda}_g/4$ 지점에 위치한 ${\lambda}_g/8$ 모노폴 안테나에 의해 $TE_{102}$ 모드로 동작되며, 노출 장치 내부에 내부 직경이 8.5 cm인 petri dish 1개를 노출시킬 수 있다. 세포실험용 전자파 노출 장치는 구형 공진기형으로 수치 해석 기법 중 하나인 FDTD 방법을 사용하여 SAR을 해석하였고 온도 프로브(model 790, Luxtron Corp)를 이용해 측정하였다.

자계 균일 공간 확보를 위한 소동물 실험용 5G급 자계 발생장치의 최적 설계 (Sptimum Design of a Uniform Magnetic Field Exposure System for a Small-Sized Animal Study)

  • 김상범;추장희;이동일;명성호
    • 한국전자파학회논문지
    • /
    • 제11권7호
    • /
    • pp.1194-1203
    • /
    • 2000
  • 1 mG부터 5 G까지 발생시킬 수 있는 소동물 실험율 60Hz 자계 발생장치를 설계하고 제작하였다. 동시에 많은 동물을 시험하기 위해서는 발생장치 내의 균일한 자계 분포 영역이 넓어야 하는데, 본 고에서는 SD-계쥐 약 50마리를 수용할수 있도록 하기 위해 소동물의 거주 공간을 장치 내부 1$\times$1$\times$1m3 크기로 하고 전체 발생장치의 크기는 1.8$\times$1.8$\times$1.8m3 입방형으로 설정하였다. 장치 내부의 자계 균일도를 검증하기 위해서 3차원 자계 계산 프로그램을 개발하였고, 이를 이용하여 거주 공간의 자계 분포가 가장 균일하게 되는 내.외곽코일의 최적 전류비 및 위치를 결정하였다. 또한 수치계산을 통한 임피던스에 근거하여 전원장치를 제작하였다. 제작된 자계 발생장치는 측정을 통하여 동물 거주 공간의 자계 최대치와 최소치의 차이가 3% 이내임을 확인할수 있었고 정밀한 소동물 자계 노출 시험용으로 사용 가능한 것으로 판단되었다.

  • PDF

이동통신 주파수 대역에서의 동물 실험용 국부 노출 장치 개발 (Development of Local-Exposure Systems for In Vivo Studies at Mobile-Phone Frequency Bands)

  • 고채옥;박민영;도현정;김정란;정기범;백정기
    • 한국전자파학회논문지
    • /
    • 제17권5호
    • /
    • pp.451-460
    • /
    • 2006
  • 본 논문에서는 이동통신 주파수 대역인 PCS와 셀룰러 대역(PCS: 1,762.5 MHz, 셀룰러: 848.5 MHz)에서 전자파의 인체 영향 규명을 위해 동물 실험용 국부 노출 장치를 설계, 제작하였다. 제작된 노출 장치는 카루셀 형의 마우스용 국부 노출 장치로서 40마리의 마우스를 동시에 노출시킬 수 있으며, 피 실험체인 마우스에 스트레스가 없도록 조명, 환기, 소음 등 환경 조건을 적절히 고려하여 제작되었다. 노출 장치의 노출량 측정을 위해 온도 프로브를 이용한 SAR측정을 수행하였다. 마우스 카데바와 고체 팬텀의 머리 부분 내부의 3점에 대해 측정하였으며, 실제로 장기간의 노출에 이용되는 조건에서 시뮬레이션 결과와 잘 일치함을 확인하였다. 현재 제작된 노출 장치는 실제 마우스의 장기 노출 실험에 사용되고 있다.

휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출 (Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure)

  • 윤지훈;손태호
    • 한국전자파학회논문지
    • /
    • 제16권8호
    • /
    • pp.810-814
    • /
    • 2005
  • TEM 셀 내에 있는 혈액에 대한 삽입 손실과 반사율을 측정하여, 원하는 혈액 흡수 SAR(Specific Absorption Rate) 선택에 따른 TEM셀 입력 전력을 구하였다. 혈액 세포는 피부 세포와 함께 전자파 영향을 연구하기 위한 기준 세포이다. 따라서 SAR에 따른 혈액 세포에 인가할 전력 산출은 정확해야 함은 물론 타당성이 있어야 한다. 이 연구에서는 g당 혈액 세포가 받는 전력을 산출하기 위해 50 g의 혈액을 이용하여 전달 전력 감소를 측정하였다. 측정된 데이터로부터 휴대폰 전자파 생체 흡수율 SAR 0.8, 1.6, 3, 4 mW/g에 해당하는 TEM셀 입력 전력을 계산하였다. 이 연구 결과는 배양 세포의 전자파 방사 장치에 응용함을 목적으로 하고 있다.

Role of Electromagnetic Field Exposure in Childhood Acute Lymphoblastic Leukemia and No Impact of Urinary Alpha-Amylase - a Case Control Study in Tehran, Iran

  • Tabrizi, Maral Mazloomi;Hosseini, Seyed Ahmad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7613-7618
    • /
    • 2015
  • Childhood acute lymphoblastic leukemia (ALL) is one of the most common hematologic malignancies which accounts for one fourth of all childhood cancer cases. Exposure to environmental factors around the time of conception or pregnancy can increase the risk of ALL in the offspring. This study aimed to evaluate the influence of prenatal and postnatal exposure to high voltage power lines on the incidence of childhood ALL. It also examines the role of various factors such as environmental factors and alpha-amylase as a marker in the development of leukemia.This cross-sectional case control study was carried out on 22 cases and 100 controls who born and lived in low socioeconomic families in Tehran and were hospitalized for therapeutic purposes in different hospitals ofrom 2013-2014. With regard to the underlying risk factors; familial history and parental factors were detected as risk factors of ALL but in this age, socioeonomic and zonal matched case control study, prenatal and childhood exposure to high voltage power lines was considered as the most important environmental risk factor (p=0.006, OR=3.651, CI 95% 1.692-7.878). As the population study was from low socioeconomic state, use of mobiles, computers and microwaves was negligible. Moreover prenatal and postnatal exposure to all indoor electrically charged objects were not detected as significant environmental factors in the present study. This work defined the risk of environmental especially continuous pre and postnatal exposure to high voltage power lines and living in pollutant regions through the parents or children as well as the previously described risk factors of ALL for the first time in low socioeconomic status Iranian population.

근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가 (Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF))

  • 박경호;안용호;김태전
    • 대한임상검사과학회지
    • /
    • 제37권3호
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

원자력발전소 안전 관련 디지털 기기의 내환경검증 (Environmental Qualification) 동향 (Trend of Environmental Qualification of Safety-Related Digital Equipment in Nuclear Power Plants)

  • 고재승;김상은;김성렬
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.7-15
    • /
    • 2024
  • Environmental qualification is required for safety related electrical equipment under harsh environments located in nuclear power plants according to 10 CFR 50.49 and RG 1.89. As analog technology has recently been replaced by digital technology, NRC established RG 1.209 as a regulatory guideline for environmental qualification of safety related computer-based I&C system located in mild environments, requiring evaluation for electromagnetic compatibility, smoke exposure and type test for actual service conditions such as temperature and humidity. In this paper, the trend of environmental qualification for digital equipment is analyzed by comparing the environmental qualification requirements between digital and analog equipment.

송전선로 부근과 가전제품의 전자계 측정 (Measurements of Electric and Magnetic Fields in the Vicinity of Transmission Lines and Electric Appliances)

  • 김상범;조성배;이동일;신구용;김정부
    • 한국전자파학회논문지
    • /
    • 제9권5호
    • /
    • pp.687-697
    • /
    • 1998
  • 최근 국내 전력설비에서 발생하는 전자계에 대한 관심이 증가하고 있지만 이에 대한 정확한 자료 파악은 극히 미미한 실정이다. 본고에서는 송전선로에서 발생하는 전계와 자계의 수준을 알아보기 위하여 전국 1537H의 송전 선로를 대상으로 전계와 자계를 측정하였다. 측정 지점의 전계와 자계 최대치들의 중간값은 각각 0.47 kV /m, 11.6 mG 최고 값은 각각 3.16 kV /m, 125 mG로 나타났으며, 전세계의 전자계 관련 권고치나 기준치에 비해 낮은 값임을 알 수 있었다. 아울러 몇 가지 경우에 대하여 가전제품에서 발생하는 자계와 일일 자계 노출량올 측정 하였고 이를 송전선로의 자계 크기와 비교하였다.

  • PDF