• Title/Summary/Keyword: electrolyte concentration

Search Result 686, Processing Time 0.03 seconds

Effect of Oral Administration of DiakurTM (a Glucose and Electrolytes Additive) on Growth and Some Physiological Responses in Broilers Reared in a High Temperature Environment

  • Takahashi, Kazuaki;Akiba, Yukio
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.9
    • /
    • pp.1341-1347
    • /
    • 2002
  • An experiment was conducted to determine effects of oral administration of $Diakur^{TM}$ (an additive of glucose and electrolytes for young calves) on growth performance and some physiological responses in male broilers reared in a high temperature. A 2 by 3 factorial arrangement test of 2 temperatures (24 and $36^{\circ}C$) and 3 levels of oral administration of the glucose and electrolytes additive, $Diakur^{TM}$, (0, 150 and 300 mg/day/100 gBW) were applied in the experiment. Male broiler chicks (2 weeks of age) were assigned to six groups and received dietary and temperature treatments for 7 days. The additive of glucose and electrolytes was suspended with water and intubated into crop twice a day (08:00 and 17:00). Oral administration of the additive prevented decreases in food intake and growth rates in broilers due to exposure of the hot environment. Oral administration of the additive also improved a lowered electrolyte ($Na^+$ + $K^+$ - $Cl^-$) balance in plasma, low mitogenic response of blood mononuclear cell and an increase in glucose concentration due to exposure to the high environmental temperature. Oral administration of the additive increased rectal temperature regardless of environmental temperatures. On the other hand, blood pH, $pCO_2$ and $HCO_3$ - concentration, and plasma creatine kinase activity were not affected by the oral administration. The results suggested that oral administration of the glucose and electrolytes additive, $Diakur^{TM}$ during heat stress did not only prevent decrease in growth performance, but also normalized some physiological and immunological responses in male broilers.

The Operation of Polymer Electrolyte Membrane Fuel Cell using Hydrogen Produced from the Combined Methanol Reforming Process

  • Park, Sang Sun;Jeon, Yukwon;Park, Jong-Man;Kim, Hyeseon;Choi, Sung Won;Kim, Hasuck;Shul, Yong-Gun
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.146-152
    • /
    • 2016
  • A combined system with PEMFC and reformer is introduced and optimized for the real use of this kind of system in the future. The hydrogen source to operate the PEMFC system is methanol, which needs two parts of methanol reforming reaction and preferential oxidation (PROX) for the hydrogen fuel process in the combined operation PEMFC system. With the optimized methanol steam reforming condition, we tested PROX reactions in various operation temperature from 170 to 270 ℃ to investigate CO concentration data in the reformed gases. Using these different CO concentration, PEMFC performances are achieved at the combined system. Pt/C and Ru promoted Pt/C were catalysts were used for the anode to compare the stability in CO contained gases. The alloy catalyst of PtRu/C shows higher performance and better resistance to CO than the Pt/C at even high CO amount of 200 ppm, indicating a promotion not only to the activity but also to the CO tolerance. Furthermore, in a system point of view, there is a fluctuation in the PEMFC operation due to the unstable fuel supply. Therefore, we also modified the methanol reforming by a scaled up reactor and pressurization to produce steady operation of PEMFC. The optimized system with the methanol reformer and PEMFC shows a stable performance for a long time, which is providing a valuable data for the PEMFC commercialization.

A Study on the Characteristics of Solid Capacitor According to the Pyrolysis Methods (열분해 방식에 따른 고체 커패시터의 특성연구)

  • Kim, Jaekun;Yu, Hyungjin;Hong, Woonghee
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.614-622
    • /
    • 2006
  • A Study on the characteristics of $Ta/Ta_2O_5/MnO_2$ capacitor applied $MnO_2$ by means of pyrolysis of manganese nitrate solution was carried out. Single phase of $MnO_2$ was obtained in the pyrolysis temperature range of 230 to $250^{\circ}C$ by TG/DSC analysis on manganese nitrate solution. Temperature of pyrolysis, concentration of manganese nitrate solution and the number of pyrolysis were selected for the basic parameters of embodying $MnO_2$ solid electrolyte and then the effects of these parameters on the characteristics of capacitor were estimated. The characteristics of capacitor pyrolyzed radiationally was superior to that of capacitor pyrolyzed convectionally on the basis of these optimized parameter conditions. It was verified that radiational pyrolysis formed smaller spherical $MnO_2$ particles than those of convectional one relatively and these facts resulted in forming uniform and dense solid electrolyte layer into the microporous sintered body of capacitor.

Electrical Conduction in Y2O3-doped SrZrO3-metal Electrode System (Y2O3가 도핑된 SrZrO3-금속전극계의 전기전도 특성)

  • Baek, Hyun-Deok;Lee, Poong-Hun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.4
    • /
    • pp.367-376
    • /
    • 2002
  • Electrical conduction in $SrZr_{1-x}Y_xO_{3-\delta}$((x=0.05, 0.10)-metal electrode system was investigated by impedance spectroscopy and two-probe d.c. conductivity measurement. Electrode conductivity in anodic direction varies with $P_W^{1/2}$( and that in cathodic direction with $P_{O2}^{1/4}$ in oxidizing atmosphere. In hydrogen atmosphere, the addition of water vapor increased the electrode conductivity both in anodic and cathodic direction. Increasing dopant concentration from 5 to 10% showed a more than four times increase in anodic conduction as well as bulk conduction of the solid electrolyte. This observation implies that unfilled oxygen vacancy concentration increases rapidly as the dopant content increases in humid atmosphere. The activation energy of cathodic conduction in Pt and Ag electrode was nearly same below $800^{\circ}C$ which means the rate of cathodic reaction is determined by the reaction in the electrolyte surface rather than on the metal electrodes.

A study on corrosion resistance and surface properties of AZ31 alloy according to Ca-GP addition during PEO treatment (PEO 처리시 Ca-GP첨가에 따른 AZ31합금의 내식성 및 표면특성에 관한 연구)

  • Lee, Jun-Su;Park, Je-Shin;Park, Il-Song
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.238-247
    • /
    • 2021
  • PEO (plasma electrolytic oxidation) was applied to modify the surface of AZ31 magnesium alloy in this study. The mixed solution of sodium hydroxide (NaOH) and sodium silicate (Na2SiO3) was used as the electrolyte, and 0 - 0.05 g/L of Ca-GP (Glycerol Phosphate Calcium salt) was added in the electrolyte as an additive. PEO treatment was conducted at a current density of 30mA/cm2 for 5 minutes using a DC power supply. The surface properties were identified by SEM, XRD and surface roughness analyses, and the corrosion resistance was evaluated by potentiodynamic polarization and immersion tests. In addition, the biocompatibility was evaluated by immersion test in SBF solution. As the concentration of Ca-GP was increased, the surface morphology was denser and more uniform, and the amount of Ca and the thickness of oxide layer increased. Only Mg peak was observed in XRD analysis due to very thin oxide layer. The corrosion resistance of PEO-treated samples increased with the concentration of Ca-GP in comparision with the untreated sample. In particular, the highest corrosion resistance was identified at the group of 0.04g Ca-GP through potentiodynamic polarization and immersion tests in saline solution (0.9 wt.%NaCl). During the immersion in saline solution, pH rapidly increased at the beginning of immersion period due to rapid corrosion, and then increase rate of pH decreased. However, the pH value in the SBF temporarily increased from 7.4 to 8.5 during the day, then decreased due to the inhibition of corrosion with HA(hydroxyapatite) formation.

Numerical simulation of electrokinetic dissipation caused by elastic waves in reservoir rocks

  • Zhang, Xiaoqian;Wang, Qifei;Li, Chengwu;Sun, Xiaoqi;Yan, Zheng;Nie, Yao
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.11-20
    • /
    • 2019
  • The use of electrokinetic dissipation method to study the fluid flow law in micro-pores is of great significance to reservoir rock microfluidics. In this paper, the micro-capillary theory was combined with the coupling model of the seepage field and the current field under the excitation of the harmonic signal, and the coupling theory of the electrokinetic effect under the first-order approximation condition was derived. The dissipation equation of electrokinetic dissipation and viscous resistance dissipation and its solution were established by using Green's function method. The physical and mathematical models for the electrokinetic dissipation of reservoir rocks were constructed. The microscopic mechanism of the electrokinetic dissipation of reservoir rock were theoretically clarified. The influencing factors of the electrokinetic dissipation frequency of the reservoir rock were analyzed quantitatively. The results show that the electrokinetic effect transforms the fluid flow profile in the pores of the reservoir from parabolic to wavy; under low-frequency conditions, the apparent viscosity coefficient is greater that one and is basically unchanged. The apparent viscosity coefficient gradually approaches 1 as the frequency increases further. The viscous resistance dissipation is two orders of magnitude higher than the electrokinetic effect dissipation. When the concentration of the electrolyte exceeds 0.1mol/L, the electrokinetic dissipation can be neglected, while for the electrolyte solution (<$10^{-2}M$) in low concentration, the electrokinetic dissipation is very significant and cannot be ignored.

Modification of Tencel Fabric Treated with Chitosan( II ) - Change of Dyeing Properties - (키토산처리에 의한 텐셀 직물의 개질기능화(II) - 염색성의 변화 -)

  • 육은영;배현숙
    • Textile Coloration and Finishing
    • /
    • v.14 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Tencel fabric cationized with chitosan can be effectively dyed with anionic dyes. To investigate the change of dyeing properties of cationized Tencel fabric, some experiments were performed under the several dyeing conditions with acid and reactive dyes. Whiteness index decreased with the increment of crosslinking agent concentration. The cationized Tencel fabric was dyed well by anionic dye such as acid dye, the dyeability of reactive dye was improved by addition of a little salt without alkali. The dye fixation on the cationized Tencel fabric was increased with chitosan concentration without electrolyte and alkali. The dyeability of Tencel treated with chitosan was better than controlled Tencel, especially under the acidic conditions. According to the number and the types of functional group of reactive dyes, dye affinity of the modified Tencel fabric varied and wash fastness of acid dye was better than reactive dye.

Electrosorption of Uranium Ions in Liquid Waste

  • Lee, Hye-Young;Jung, Chong-Hun;Oh, Won-Zin;Park, Jin-Ho;Shul, Yong-Gun
    • Carbon letters
    • /
    • v.4 no.2
    • /
    • pp.64-68
    • /
    • 2003
  • A study on the electrosorption of uranium ions onto a porous activated carbon fiber (ACF) was performed to treat uraniumcontaining lagoon sludge. The result of the continuous flow-through cell electrosorption experiments showed that the applied negative potential increased the adsorption kinetics and capacity in comparison to the open-circuit potential (OCP) adsorption for uranium ions. Effective U(VI) removal is accomplished when a negative potential is applied to the activated carbon fiber (ACF) electrode. For a feed concentration of 100 mg/L, the concentration of U(VI) in the cell effluent is reduced to less than 1 mg/L. The selective removal of uranium ions from electrolyte was possible by the electrosorption process.

  • PDF

Experimental Study of Acid-Base Balance and Variations of Heart Rate, Fluid and Electrolyte by Electrical Stimulation according to the Physical Constitutions (체질에 따른 산.염기평형과 전기자극에 의한 맥박수 및 체액전해질의 변동에 관한 실험적 고찰)

  • 조봉관;배종일
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.349-354
    • /
    • 1993
  • To investigate the relations between the physical constitutions, the acid-base balance, and the autonomic nervous function, the blood gas, the heart rate and the concentrations of Na, K of serum were measured pre-and poststimulation. As the result, it is shown that in the normal condition the macro-negative(strong liver- weak lung type) is the metabolic alkalosis, the macro-positive (strong lung-weak liver type) is the metabolic acidosis, the micro-negative(strong kidney-weak spleen type) is the alkalosis and the micro-positive (strong spleen-weak kidney type) is the acidosis. And the ntacro-positive and micro-positive are the sympathetic lead, the macro-negative and micro-negative are the parasympathetic lead. In the macro-positive and micro-positive subjects, the concentration of K in serum is relatively high. This si coincided with the acidosis. But in the macro-negative and micro-negative subjects, the concentration of K in serum is relatively low. This is coincided with the alkalosis.

  • PDF

Mass Transfer to Amalgamated Copper Rotating Disk Electrode

  • Sulaymon, Abbas H.;Abbar, Ali H.
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.165-171
    • /
    • 2012
  • An experimental study of mass transfer to an amalgamated copper rotating disc electrode has been employed to determine an empirical correlation for the mass transfer rate in laminar flow. The study was performed in a three-electrodes configuration using 0.1 M boric acid and 0.1M potassium chloride as supporting electrolyte with Zn (II) concentration in the range (25-100 mg $dm^{-3}$). Polarization curves at different zinc ion concentration are reported. Hydrogen and oxygen reduction has also been considered.The diffusion coefficients and mass transfer coefficient were obtained using limiting diffusion current technique based on zinc ion reduction. A least squares analysis indicates that the laminar flow results for 13067 < Re > 57552 and 550 < Sc > 1390 can be correlated by the following equation with correlation coefficient (CR) equal to 0.98: $sh=0.61Re^{0.5}Sc^{1/3}$.