이종재료(알루미늄합금-강판)의 저항 점용접에 관한 연구 (A Study on Resistance Spot Welding of Dissimilar Sheet Metals(Aluminum Alloy - Steel Sheets))

  • 손병천;우승엽;이재범;최용범;장희석
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.42-62
    • /
    • 1997
  • Resistance spot welding has been widely used in the sheet metal joining processes because of its high productivity and convenience. Recently, automobile industries are trying to replace partly steel sheets with aluminum alloy sheets. Among currently produced aluminum alloys, Al alloy sheets of Al-Mg-Si(6000 series) are being tested. Especially, 6000 series are the most probable substitute in view of strength and weldability. In this paper, an attempt was made to apply resistance spot welding to joining of dissimilar sheet metals (KS6383+SCPZn or KS6383+SHCP). An effort was made to balance heating rate in the Al alloy with that in the steel sheets by increasing electrode tip diameter. Although resistance spot welding of Al alloy sheet and sheet metals does not produce desirable nugget, it proved to have reasonable strength if optimal weld condition is found by tensile-shear strength and fatigue life test. Since spot weld joints in automobile are always experiencing repeated load, spot welding methodology proposed in this paper is found to be not suitable to automobile body manufacturing.

  • PDF

RF 고전력 스트레스에 의한 SAW Device의 고장메카니즘 분석 (Failure Mechanism Analysis of SAW Device under RF High Power Stress)

  • 김영구;김태홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.215-221
    • /
    • 2014
  • 본 논문에서는 RF 고전력 스트레스에 의한 SAW 디바이스의 신뢰성 분석을 위하여 향상된 내전력 시험시스템 및 시험방법을 제안하고 고장분석을 통해 고장메카니즘을 분석하였다. 광학현미경, SEM(Scanning Electron Microscope) 및 EDX(Energy Dispersive X-ray Spectro-scopy)장비를 이용하여 고장 분석한 결과, SAW 디바이스의 고장메카니즘은 고전류 밀도 및 고온 조건에서 줄열에 의한 Electromigration으로 분석하였다. Electromigration은 IDT전극에 void와 hillock을 생성하고, 그 결과로 전극이 단락과 단선되어 삽입손실이 증가하는 것이다. 제안된 내전력 시험시스템과 방법을 이용하여 450MHz CDMA용 SAW 필터의 가속수명시험을 수행하고, 아이링 모델과 와이블 분포를 이용하여 SAW 필터의 $B_{10}$수명은 98,500시간으로 추정하였다.

단일탐침법을 사용한 평판형 광원의 제논 (Xe) 플라즈마 특성 연구 (Xe Plasma Property with Flat Lamp by Langmuir Probe)

  • 백광현;이종찬;황명근;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.50-54
    • /
    • 2006
  • The study on discharge of the flat lamp lighting source has been requested increasingly. To improve the brightness, life time and efficiency of flat lamp, the plasma diagnosis of flat lamp lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density with single Langmuir probe in flat lamp. Pressure conditions to test the plasma discharge from 100 Torr to 300 Torr. The power supply was PDS-4000 with frequency 20kHz and duty ratio $20\%.$ Form these experimental results, electron temperature was decreased according to increase the gas pressure and the voltage while electron density was increased.

태양전지모듈 제조를 위한 요소기술연구 (A Study on the Element Technology for PV Module Manufacturing)

  • 김기환;유권종;박경은;한득영;안형근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1365-1367
    • /
    • 2003
  • In this paper, element technologies such as soldering. arrangement and lamination processes for photovoltaic module manufacture were examined and described as main processes. Especially solder paste and temperature condition in soldering process, loss factor in arrangement process and process conditions in lamination process are investigated to minimize the electrical loss. As a results, temperature condition in soldering process was found to be critical to contact resistance of electrode and life-time. Productivity of the process decreases dramatically by physical damage during arrangement process. Pressure level and press condition of upper chamber in lamination process were important parameters for the reliability. According to the test result of photovoltaic module, electrical properties dropped about $5{\sim}25%$ after 5 years.

  • PDF

탄소나노튜브 방출원을 통한 초소형 질량분석기의 이온화 향상 (The Improvement of the Ionization on Micro Mass Spectrometer using Carbon Nanotube Emitter)

  • 송성호;한규성;;이순일;양상식
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.1004-1009
    • /
    • 2009
  • Recently, mass spectrometers are widely used for in-situ chemical analysis. It has rapid response and high sensitivity. In this paper, we present the fabrication and test of a cold cathode emitter for micro mass spectrometer using CNTs(Carbon nano tubes). The CNTs have good mechanical, electrical and chemical characteristics. So they have a long life time and strong robustness. The micro mass spectrometer is composed of the glass substrate and the silicon substrate. The glass substrate is constructed by electrodes for TOF(Time-of-flight) which analyze an ion with mass to charge ratio as ion separator. The silicon substrate is highly doped wafer which is patterned for gate electrode and then 100 11m dry etching to grow the CNTs as the electron emitter. The CNTs are grown by HFCVD(Hot filament chemical vapor deposition) with sputtering the catalyst. We successfully attained to grow the CNTs and to test the characteristics.

Zn/AgO Secondary Battery용 아연 양극의 성능에 미치는 첨가제의 영향 (The Effect of Additives on the Properties of Zn Electrode in Zn/AgO Secondary Battery)

  • 박경화;김창환;문경만
    • 전기화학회지
    • /
    • 제6권3호
    • /
    • pp.196-202
    • /
    • 2003
  • 아연 양극의 성능을 향상시킬 목적으로 4가지 종류의 첨가제의 효과를 연구하였다. $Pb_3O_4(0.5, \;1.0&\;2.0wt\%)$와 4가지 종류의 첨가제$(0.4wt\%\;of\;Ca(OH)_2,\;0.025M\;of\;Citrate,\;tartrate\;and\;Gluconate)를\;40wt\%$ KOH 전해질 용액에 용해시켜 부식전위 측정, 분극실험, 충$\cdot$방전 사이클 수명시험을 행하였다. 부식전위는 시간이 흐름에 따라 높은 방향으로 이행하였고 $Pb_3O_4$의 량이 증가함에 따라 반복적으로 전위가 상승과 하강을 거듭하였다. 더욱이 내식성은 무첨가의 경우에 비해 확실하게 증가하였고 첨가제가 들어간 경우 충$\cdot$방전 특성이 향상되었다. SEM사진을 분석한 결과 $0.5wt\%\;Pb_3O_4$ 만을 첨가한 경우와 Tartrate가 첨가된 경우의 표면 형상이 유사하였으며, 다른 첨가제의 경우 표면에 수지상 결정의 성장이 나타났다. 결과적으로 다른 첨가제와 비교하여 Tartrate의 경우 내식성 효과뿐만 아니라 충$\cdot$방전 특성도 우수함을 보여주었다.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구 (A Study on Smart Ground Resistance Measurement Technology Based on Aduino)

  • 김홍용
    • 한국재난정보학회 논문집
    • /
    • 제17권4호
    • /
    • pp.684-693
    • /
    • 2021
  • 연구목적: 아두이노를 이용하여 실시간 대지저항 데이터를 취득할 수 있는 스마트 대지저항 측정장치를 개발하여 낙뢰 등 이상전압으로부터 안전한 설비환경을 구축하는것에 목적이 있다. 연구방법: 본 논문은 아두이노와 전력선 통신(PLC) 체계를 갖춘 대지저항 취득 및 분석 시스템을 개발하여 설계모델과 적용사례를 연구하였다. 경남지역의 풍력발전 단지 내 일부 부지를 테스트 베드로 선정하여 신기술을 적용한 실시간 대지저항 데이터를 취득하였다. 전극배열은 웨너(Wenner) 4전극배열과 슐렘버거(Schlumberger) 전극배열을 혼용한 스마트 전극배열을 채택하였다. 연구결과: 본 기술의 특징은 첫 번째로 스마트 다 전극의 깊이를 각기 다르게 편성해 층간에 특이성을 가지는 지층 구조에도 취득 데이터의 오차범위를 축소하였다. 두 번째로 스마트 접지전극에서 취득한 대지저항 데이터의 정보를 사물인터넷으로 실시간 송·수신이 가능하도록 IT융합 기술을 적용하였다. 마지막으로 규칙적인 관리 체계를 구축하고 Server에 축적된 빅 데이터를 분석하여 다양한 요소들의 변화추이를 확인할 수 있으며, IT융합 환경에 최적의 접지 알고리즘과 접지시스템 설계 모델링이 가능하다. 결론: 본 기술은 4차 산업 시대에 근간이 되는 도시 기반시설에 낙뢰로 인한 서지(Surge)의 피해를 줄이고 최적화된 접지시스템 모델을 설계하여 사용자의 안전과 생명을 보호 할 것이다. 또한 순수 국산 기술력의 지적재산권을 확보하여 포스트 코로나 시대에 팬데믹으로 정체되어있는 우리산업의 일자리 창출과 활기를 불어넣는 효과도 기대된다.

Piezoelectric immunosensor for the detection of Edwardsiellosis

  • Hong, Sung-Rok;Choi, Suk-Jung;Jeong, Hyun-Do;Hong, Su-Hee
    • 한국어병학회지
    • /
    • 제20권3호
    • /
    • pp.307-313
    • /
    • 2007
  • In this study, a QCM biosensor was made to detect Edwardsiella tarda (E. tarda) using a specific antibody. A 9 MHz AT-cut piezoelectric wafer layered with two gold electrodes of 5mm diameter had a reproducibility of 0.1 Hz in frequency response and was used as the transducer of the QCM biosensor. Self assembled layer (SAM) was conformed on a quartz crystal by treating with 3-mer-captopropionic acid (MPA) and activated with N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The resulting NHS group was further converted to hydrazide by the reaction with hydrazine. Aldehyde group was introduced into the carbohydrate moiety of anti-E. tarda antibody by the reaction with periodic acid and was used to immobilise the antibody through the reaction with hydrazide group on the electrode surface. A baseline was established in the presence of phosphate-buffered saline (PBS) and a resonant frequency (F1) was measured. Sample was added to the sensor surface and second resonant frequency (F2) was measured after unbound substances were washed out with PBS several times. Finally, the frequency shift (ΔF) representing the mass change was calculated by subtracting F2 from F1. After adding the oxidized anti-E. tarda antibody to the electrode surface containing hydrazide group, frequency shift of 288.811.4 Hz (mean S.E) was observed, thus proving that considerable amount of antibody was immobilized. In the immunoassay test, the frequency shift of 1877.75 Hz, 580.67 Hz, 221.39 Hz, 7.671.83 Hz (mean S.E) were observed at doses of 1000, 500, 100, 50 g of bacterial cells, respectively. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration with 0.2 M Tris-glycine and 1 % DMSO, pH 2.3 more than ten times.

TheraBand를 이용한 견관절 외전시 삼각근과 극상근의 근전도 변화 (A Changes of Electromyogram Activities in Deltoideus and Supraspinatus During Shoulder Abduction Using TheraBand)

  • 박관용;이석민;이재구
    • 대한물리치료과학회지
    • /
    • 제9권3호
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this study was to compare the changes of muscle activities in deltoid with those in supraspinatus using electromyography(EMG) while subjects abducted their shoulder to different angles with different resistance. Methods : 20 volunteers who were comprised of 10 males(mean age: $21.2{\pm}2.0$) and 10 females(mean age: $20.2{\pm}1.6$) were collected. Surface electrodes were attached on deltoid and supraspinatus muscle for recording. Each reference electrode was located 3 cm to the each recording electrode. Muscle action potentials were recorded with changing the angle of shoulder abduction, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. This procedure was repeated with different resistance 0 pound, 2 pounds, 4.5pounds. The angle of shoulder abduction was determined by clinical goniometer. SPSS(Statistical Program for Social Science)/WIN 10.0 was used for statistics. Analysis included ANOVA, T-test. Results : The following results were obtained in this study. 1. There was significant differences during isometric shoulder abduction $30^{\circ}$, $60^{\circ}$, $90^{\circ}$ comparing muscle activity in deltoid and supraspinatus muscles at 0 pound, 2pound, 4.5pound resistance(p<0.05). 2. There was no useful significant in the deltoid and supraspinatus muscles activity EMG compared by physical condition. 3. Their was significant in the deltoid EMG compared by gender t=-5.41, P<0.01, but no difference in the supraspinatus EMG(P=0.333 >a=0.05). Conclusions: There are many previous studies on influence of shoulder angles and speeds of muscle activity. However most of them placed the focus on isotonic or isokinetic exercise, or shoulder function. But this study was done during isometric exercise, which is better for early assessment and treatment for injured patients. There is strong relationship between the shoulder angle with resistance in deltoid supraspinatus muscle activity. We conclude that it is important to apply isometric shoulder abduction exercise with correct angle and resistance especially in early stage.

  • PDF