• Title/Summary/Keyword: electrochemical response

Search Result 222, Processing Time 0.021 seconds

An Experimental Study on the Effect of Sensor Line Number on the Reactivity Characteristic of Corrosion Sensor Reactive with Chloride Ion to Immigrate into Concrete (콘크리트내로 침투하는 염소이온 반응형 부식센서의 응답특성에 미치는 센서 세선 수의 영향에 관한 실험적 연구)

  • Lee, Hyun-Seok;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.143-152
    • /
    • 2014
  • In this study, the sensor response and sensitivity is experimented and analyzed quantitatively by the line numbers of chlorine ion reaction type corrosion sensor that is developed. The sensor response of the developed corrosion sensor is verified with properties of chlorine ion. The multilineal sensor is shown a large resistance change more than the single line sensor by damage of the sensor. And, the resistance change of sensor is as large as high concentration of NaCl aqueous solution, the sensitivity of multilineal sensor is higher than single line sensor's, and the depth of sensor's location is as large as the increasing of resistance change time (cycle). These results suggest that, the developed corrosion sensor could sense corrosion reaction, sensor sensitivity and change of resistance for chloride ion. Especially, It was judged that 7 line sensor was the most superior for monitoring chloride ion immigration into concrete.

Electrogenerated Chemiluminescence Sensor Based on Tris(2,2'-bipyridyl) ruthenium(II) Immobilized in the Composite Film of Multi-walled Carbon Nanotube/Sol-gel Zinc oxide/Nafion

  • Choi, Eun-Jung;Kang, Chang-Hoon;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2387-2392
    • /
    • 2009
  • A composite film of multi-walled carbon nanotube (MWCNT)/sol-gel-derived zinc oxide(ZnO)/Nafion has been utilized as an efficient immobilization matrix for the construction of a highly sensitive and stable tris(2,2'-bipyridyl) ruthenium(II) (Ru(${bpy)_3}^{2+})$ electrogenerated chemiluminescence (ECL) sensor. The electrochemical and ECL behaviors of Ru(${bpy)_3}^{2+})$ ion-exchanged into the composite film were strongly dependent upon the sol-gel preparation condition, the amount of MWCNT incorporated into the ZnO/Nafion composite film, and the buffer solution pH. The synergistic effect of MWCNTs and ZnO in the composite films increased not only the sensitivity but also the long-term stability of the ECL sensor. The present ECL sensor based on the MWCNT/ZnO/Nafion gave a linear response ($R^2$ = 0.999) for tripropylamine concentration from 500 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 15 nM. The present ECL sensor showed outstanding long-term stability (94% initial signal retained for 5 weeks). Since the present ECL sensor exhibits large response towards NADH, it could be applied as a transduction platform for the ECL biosensor in which the NADH is produced from the dehydrogenase-based enzymatic reaction in the presence of NA$D^+$ cofactor.

Determination of Glucose Using Enzyme Immobilized Membrane (효소 고정화 막을 이용한 Glucose의 정량)

  • Kim, Im Ok;Kwak, Kyeong Do;Ha, Youn Shick;Kwon, Hyo Shik;Seo, Moo Lyong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.264-270
    • /
    • 1999
  • Enzyme electrodes for amperometric measurement of glucose were prepared by immobilization of glucose oxidase on an Immobilon-AV Affinity membrane and attachement to a Pt electrodes. The electrochemical oxidation of Hz02 was monitored at +0.8V vs. Ag/AgCl. Response was linear from 0.2 mM to 20mM. The detection limit was 10m3 mM. Response time, the optimum pH and life time of enzyme immobilized membrane was 12 seconds, pH 5.5(CH3COONaJCH3COOH) and about 27 days, respectively. When the enzyme electrode was applied for the determinaion of glucose with amperometric method, other physiolosical materials have not interfered. Also, we compared the result with that from AOAC(Association of Offical Analytical Chemists) method, measuring the glucose in sweet potato. The relative error was 0.1%.

  • PDF

New Equivalent Circuit Model for Interpreting Spectral Induced Polarization Anomalous Data (광대역유도분극 이상 자료의 해석을 위한 새로운 등가회로 모델)

  • Shin, Seungwook;Park, Samgyu;Shin, Dongbok
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.4
    • /
    • pp.242-246
    • /
    • 2014
  • Spectral induced polarization (SIP) is a useful technique, which uses electrochemical properties, for exploration of metallic sulfide minerals. Equivalent circuit analysis is commonly conducted to calculate IP parameters from SIP data. An equivalent circuit model, which indicates the SIP response of rock, has a non-uniqueness problem. For this reason, it is very important to select the proper model for accurate analysis. Thus, this study focused on suggesting a new model, which suitable for the analysis of an anomalous SIP response, such as ore. A suitability of the new model was verified by comparing it with the existing Dias model and Cole-Cole models. Analysis errors were represented as a normalized root mean square error (NRMSE). The analysis result using the Dias model was the NRMSE of 10.50% and was the NRMSE using the Cole-Cole model of 17.03%. Howerver, because the NRMSE of the new model is 0.87%, it is considered that the new model is more useful for analyzing the anomalous SIP data than other models.

Introduction of Various Amine Groups onto Poly(glycidyl methacrylate)-g-MWNTs and their Application as Biosensor Supports (폴리(글리시딜 메타크릴레이트)가 그래프트된 다중벽 탄소나노튜브에 다양한 아민 그룹의 도입과 바이오센서 지지체로서의 응용)

  • Chung, Da-Jung;Kim, Ki-Chul;Choi, Seong-Ho
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.470-477
    • /
    • 2012
  • A tyrosinase-immobilized biosensor was developed based on various amine-modified multi-walled carbon nanotube (MWNT) supports for the detection of phenolic compounds. MWNTs with various amine groups were prepared by radiation-induced graft polymerization of glycidyl methacrylate (GMA) onto MWNT supports and the subsequent amination of poly(GMA) graft chains. The physical and chemical properties of the poly(GMA)-grafted MWNT supports and the aminated MWNT supports were investigated by SEM, XPS, and TGA. Furthermore, the electrochemical properties of the prepared tyrosinase-modified biosensor based on MWNT supports with amine groups were also investigated. The response of the enzymatic biosensor was in the range of 0.1-0.9 mM for the concentration of phenol in a phosphate buffer solution. Various parameters influencing biosensor performance have been optimized: binder effects, pH, temperature, and the response to various phenolic compounds. The biosensor was tested on phenolic compounds contained in two different commercial red wines.

Photoelectrochemical Behaviour of Oxide Films on Ti-Ga2O3 Alloy (Ti-Ga 합금 위에 형성된 산화티타늄 피막의 광 전기분해 특성에 관한 연구)

  • Park, Seong-Yong;Cho, Byung-Won;Yun, Kyung-Suk;Lee, Eung-Cho
    • Journal of Hydrogen and New Energy
    • /
    • v.3 no.2
    • /
    • pp.25-33
    • /
    • 1992
  • With the aim to obtain $TiO_2$ films with an increased photorespones and absorbance in the visible region of the solar spectrum, the direct oxidation of titanium alloys were performed. In this study, $Ti-Ga_2O_3$ alloy was prepared by mixing, pressing and arc melting of appropriate amounts of titanium and $Ga_2O_3$ powder. Electrochemical measurements were performed in three electrode cell using electrolyte of 1M NaOH solution. The oxide films on $Ti-Ga_2O_3$ alloy was composed of $Ti_2O$, TiO, $TiO_2$, $Ga_2TiO_5$. The free energy efficiency (${\eta}e$) of $Ti-Ga_2O_3$ oxide films had 0.8~1.3 % and were increased with the increase of $Ga_2O_3$ content up to 10wt %. The onset potential ($V_{on}$) had -0.8V~0.9V ranges and were shifted to anodic direction with the increase of $Ga_2O_3$ content. The spectral response of Ti-$Ga_2O_3$ oxides were similar to the response of the $TiO_2$ and their $E_g$ were observed to 2.90~3.0eV. Variations of onset potential($V_{on}$) associated with electrolyte pH were -59mV/pH. This probably reflects the nature of the bonding of $OH^-$ ion to the $TiO_2$ surface, a common phenomena in the transition-metal oxides.

  • PDF

Fabrication of Potentiometric Sodium-ion Sensor Based on Carbon and Silver Inks and its Electrochemical Characteristics (탄소 및 은 잉크 기반의 전위차 나트륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Kim, Seo Jin;Son, Seon Gyu;Yoon, Jo Hee;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.456-460
    • /
    • 2021
  • A potentiometric sodium-ion (Na+) sensor was prepared using a screen-printing process with carbon and silver inks. The two-electrode configuration of the sensor resulted in potential differences in Na+ solutions according to Nernstian equation. The obtained Na+-sensor exhibited an ideal Nernstian sensitivity, fast response time, and low limit of detection. The Nernstian response was stable when the sensor was tested for repeatability and long-term durability. The Na+-selective membrane coated onto the carbon electrode selectively passed sodium ions against interfering ions, indicating an excellent selectivity. The portable Na+-sensor was finally fabricated using a printed circuit system, demonstrating the successful measurements of Na+ concentrations in various real samples.

Amperometric Morphine Detection Using Pt-Co Alloy Nanowire Array-modified Electrode

  • Tao, Manlan;Xu, Feng;Li, Yueting;Xu, Quanqing;Chang, Yanbing;Wu, Zaisheng;Yang, Yun-Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1968-1972
    • /
    • 2010
  • Pt-Co alloy nanowire array was directly synthesized by electrochemical deposition with polycarbonate template at -1.0V and subsequent chemical etching of the template. The use of Pt-Co alloy nanowire array-modified electrode (Pt-Co NAE) for the determination of morphine (MO) is described. The morphology of the Pt-Co alloy nanowire array has been investigated by scanning electron microscopy (SEM) and energy disperse X-ray spectroscopy (EDS) analysis), respectively. The resulting Pt-Co NAE offered a linear amperometric response for morphine ranging from $2.35\times10^{-5}$ to $2.39\times10^{-3}$ M with a detection limit of $7.83\times10^{-6}$ M at optimum conditions. This sensor displayed high sensitivity and long-term stability.

Development of a cholesterol biosensor modified with carbon nanotube (탄소나노튜브를 이용하여 개조한 콜레스테롤 바이오 센서 개발)

  • Kim, Haidong
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.425-429
    • /
    • 2015
  • A cholesterol biosensor was developed using a modified carbon electrode with carbon nanotubes. The disposable cholesterol biosensor was modified with carbon nanotubes to enhance electron transfer during the enzymatic reaction of cholesterol. Cholesterol oxidase and peroxidase, with potassium ferrocyanide as a mediator, were immobilized on a screen-printed carbon nanotube electrode. The electrochemical cholesterol biosensor developed using carbon nanotubes showed a rapid and reliable signal for measuring total cholesterol. The cholesterol sensor showed a linear response in 5 seconds with a small volume (0.5 μL) in the range of 100~400 mg/dL, with a coefficient of variation of 4.0%.

A Sensing of Glucose Solution and Diabetic Serum using Polypyrrole Nanotubules Enzyme Electrode Immobilized Glucose Oxidase (포도당 산화효소를 고정화한 Polypyrrole 나노튜뷸 효소전극의 포도당 용액 및 당뇨병 혈청에 대한 감응특성)

  • Kim, Hyun-Cheol;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.6-10
    • /
    • 2001
  • We synthesized polypyrrole (PPy) nanotubules by oxidative polymerization of the pyrrole monomer on the pore of a polycarbonate membrane. The electrochemical behavior was investigated using cyclic voltammetry and AC impedance. The redox potential was about -0.5 V vs. Ag/AgCl reference electrode, while the potential was about 0 V for electro-synthesized PPy film. It is considered as the backbone grows according to the pore wall. Therefore, it is possible to be arranged regularly. That leads to improvement in the electron hopping. The AC impedance plot gave a hint of betterment of mass transport. PPy nanotubules have improved in mass transport, or diffusion. That is because the diffusion occurs through a thin pore wall of PPy nanotubules. The kinetic parameter of PPy nanotubules enzyme electrode with glucose solution was evaluated. The formal Michaelis constant and maximum current calculated by computer were about 23.8 mmol $dm^{-3}$ and $440\;{\mu}A$ respectively. Obviously, an affinity for the substrate and current response of the PPy nanotubules enzyme electrode are rather good, comparing with that of PPy film. What is more, the enzyme electrode is sensitive to blood sugar of a diabetic serum despite an obstruction of ascorbic acid, oxygen, some protein and/or hormone.

  • PDF