• 제목/요약/키워드: electrochemical methods

검색결과 562건 처리시간 0.028초

이중 연료 엔진용 이중벽 가스 배관 이종 용접부의 매크로 및 마이크로 전기화학적 특성 (Macro and Micro-electrochemical Characteristics on Dissimilar Welding Metal of Double Wall Gas Pipe for Duel Fuel Engine)

  • 김성종;박재철;한민수;장석기
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.331-337
    • /
    • 2010
  • This study compared the macro and micro electrochemical characteristics at the local area of welding metal on dissimilar welding parts for type 304 stainless steel (SS) and type 316L SS. The materials are used for double wall gas pipe of duel fuel engine for a ship. The various potentiodynamic experiments were performed several times in 10% ${H_2C_2O_2}{\cdot}{H_2O}$ solution using macro and micro methods, respectively. The micro electrochemical experiments conducted to resolve at local area on cross-section of dissimilar welding materials by micro-droplet cell device. The micro-droplet cell techniques can be used almost electrochemical experiments to resolve corrosion characteristics of the limited electrode area of the metallic surface between wetted spot of working electrode and tip of sharpened capillary tube. The results of macro electrochemical experiments show that resistance of active dissolution reaction at welding zone was high due to low current density by formation of passivation protection film at passive region. According to the micro electrochemical experiment, the corrosion current density of welding zone and bond zone were relatively high.

Review on CNT-based Electrode Materials for Electrochemical Sensing of Ascorbic Acid

  • P Mary Rajaitha;Runia Jana;Sugato Hajra;Swati Panda;Hoe Joon Kim
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.131-139
    • /
    • 2023
  • Ascorbic acid plays a crucial role in the regulation of neurotransmitters and enzymes in the central nervous system. Maintaining an optimal level of ascorbic acid, which is between 0.6-2 mg/dL, is vital for preventing oxidative stress and associated health conditions, such as cancer, diabetes, and liver disease. Therefore, the detection of ascorbic acid is of the utmost importance. Electrochemical sensing has gained significant attention among the various detection methods, owing to its simplicity, speed, affordability, high selectivity, and real-time analysis capabilities. However, conventional electrodes have poor signal response, which has led to the development of modified electrodes with better signal response and selectivity. Carbon nanotubes (CNTs) and their composites have emerged as promising materials for the electrochemical detection of ascorbic acid. CNTs possess unique mechanical, electrical, and chemical properties that depend on their structure, and their large surface area and excellent electron transport properties make them ideal candidates for electrochemical sensing. Recently, various CNT composites with different materials and nanoparticles have been studied to enhance the electrochemical detection of ascorbic acid. Therefore, this review aims to highlight the significance of CNTs and their composites for improving the sensitivity and selectivity of ascorbic acid detection. Specifically, it focuses on the use of CNTs and their composites in electrochemical sensing to revolutionize the detection of ascorbic acid and contribute to the prevention of oxidative stress-related health conditions. The potential benefits of this technology make it a promising area for future research and development.

High-risk Human Papillomavirus Genotype Detection by Electrochemical DNA Chip Method

  • Chansaenroj, Jira;Theamboonlers, Apiradee;Chinchai, Teeraporn;Junyangdikul, Pairoj;Swangvaree, Sukumarn;Karalak, Anant;Takahashi, Masayoshi;Nikaido, Masaru;Gemma, Nobuhiro;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1151-1158
    • /
    • 2012
  • High-risk human papillomavirus (HPV) genotypes are the major cause of cervical cancer. Hence, HPV genotype detection is a helpful preventive measure to combat cervical cancer. Recently, several HPV detection methods have been developed, each with different sensitivities and specificities. The objective of this study was to compare HPV high risk genotype detection by an electrochemical DNA chip system, a line probe assay (INNO-LiPA) and sequencing of the L1, E1 regions. A total of 361 cervical smears with different cytological findings were subjected to polymerase chain reaction-sequencing and electrochemical DNA chip assessment. Multiple infections were found in 21.9% (79/361) of the specimens, most prevalently in 20-29-year olds while the highest prevalence of HPV infection was found in the 30-39-year age group. The most prevalent genotype was HPV 16 at 28.2% (138/489) followed by HPV 52 at 9.6% (47/489), with the other types occurring at less than 9.0%. The electrochemical DNA chip results were compared with INNO-LiPA and sequencing (E1 and L1 regions) based on random selection of 273 specimens. The results obtained by the three methods were in agreement except for three cases. Direct sequencing detected only one predominant genotype including low risk HPV genotypes. INNO-LiPA identified multiple infections with various specific genotypes including some unclassified-risk genotypes. The electrochemical DNA chip was highly accurate, suitable for detection of single and multiple infections, allowed rapid detection, was less time-consuming and was easier to perform when compared with the other methods. It is concluded that for clinical and epidemiological studies, all genotyping methods are perfectly suitable and provide comparable results.

The Inhibitive Effect of Poly(p-Anisidine) on Corrosion of Iron in 1M HCl Solutions

  • Manivel, P.;Venkatachari, G.
    • Corrosion Science and Technology
    • /
    • 제4권2호
    • /
    • pp.51-55
    • /
    • 2005
  • The corrosion inhibitive effect of Poly (p-Anisidine) on iron in 1M HCl with various concentrations were studied by using electrochemical methods such as impedance measurements and polarization techniques. The inhibition efficiency (IE) of Poly (p- Anisidine) was compared with its monomer and it was observed that there is a remarkable increase for the polymer. Further, it is found that the value of IE increases with increasing concentrations for both monomer and polymer of p-Anisidine.

전기화학법을 이용한 DNA Hybridization 특성 검출 (Detection of DNA Hybridization Characteristics Using Electrochemical methods)

  • 김도균;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1569-1571
    • /
    • 2002
  • The determination of DNA hybridization can apply the molecular biology research, clinic diagnostics, bioengineering, environment monitoring, food science and other application area. So, The determination of hybridization is very important for the improvement of DNA detection system. In this study, we report the characterization of the DNA hybridization by the electricalchemical methods. A new electrochemical biosensor is described for voltammetric detection of gene sequence related to probe oligonucleotide of bacterium Escherichia coli O157:H7. The biosensor involves the immobilization of a 18-mer probe oligonucleotide, which is complemetary to a specific gene sequence related to Escherichia coli O157:H7 on a gold electrode through specific adsorption. The probe oligonucleotide was used to determine the amount of target oligonucleotide in solution using mitoxantrone(MTX) as the electrochemical indicators. The cathodic peak currents $(I_{peak})$ of MTX were linearly related to the concentration of the target oligonucleotide sequence in the range $1[{\mu}M]{\sim}0.1[nM]$. The detection limit of this approach was 0.01[nM]. In addition, these indicators were capable of selectivity discriminating against various mismatching condition.

  • PDF

알칼리형 연료전지의 수소극용 Co-Mo 및 Ni-Mo 금속간화합물 전극의 전기화학적 안정성 (Electrochemical Stability of Co-Mo and Ni-Mo Intermetallic Compound Electrodes for Hydrogen Electrode of Alkaline Fuel Cell)

  • 이창래;강성군
    • 전기화학회지
    • /
    • 제2권3호
    • /
    • pp.150-155
    • /
    • 1999
  • [ $H_2-O_2$ ] 알칼리형 연료전지용 수소극으로서 아크융해법으로 제조된 Brewer-Engel type의 Co-Mo$(35\;wt\%)$ 및 Ni-Mo$(35\;wt\%)$ 금속간화합물 전극의 전기화학적 안정성이 조사되었다. $N_2$가스로 용존산소를 제거한 $80^{\circ}C$ 6N KOH 전해질 내에서 금속간화합물 전극의 전기화학적 안정성에 미치는 전해질의 농도 및 온도의 영향이 조사되었다. 또한, AFC의 정상 작동조건하에서는 Co-Mo및 Ni-Mo전극의 전기화학적 안정성에 대한 분극전압(과전압)의 영향이 논의되었다. Co-Mo전극은 Ni-Mo전극에 비하여 낮은 전기화학적 안정성을 보였다. 수소가스 평형전위로부터 낮은 양분극 과전압 하에서 Co-Mo전극에서는 Co와 Mo의 용해가 동시에 일어났다. 그러나, Co는 Mo에 비하여 급격히 용해되었다 높은 양분극 과전압에서는 전극표면에 $Co(OH)_2$ 부동태 피막이 형성되었다. Ni-Mo전극의 경우에는 Mo의 용해반응이 치밀한 $Ni(OH)_2$, 부동태 피막형성에 의하여 억제되어 우수한 전기화학적 안정성을 보였다.

Nickel Hexacyanoferrate 이온교환체의 전기화학적 특성에 관한 연구 (A Study on the Electrochemical Characteristics of the Nickel Hexacyanoferrate Ion Exchanger)

  • 황영기
    • 한국산업융합학회 논문집
    • /
    • 제19권4호
    • /
    • pp.198-205
    • /
    • 2016
  • For the study on the ion exchange of nickel hexacyanoferrate(NiHCNFe) electrode with the several cations, the film of hexacyanoferrate was prepared on the bare nickel surface by the electrochemical and chemical methods in the solution composed with 5mM K3Fe(CN)6 and 100mM KNO3. To compare the capability of the ion exchange of NiHCNFe film electrode, the repeated cyclic voltammograms were measured in the 0.5M cation nitrate solutions at $25^{\circ}C$ and pH7. It was found that the capacity of the electrochemically derivatized NiHCNFe reduced in the rate of 0.5~0.7%/cycle and was nearly exhausted at the 150th potential cycle. Better result was obtained from that the capacity loss of the chemically assembled NiHCNFe was less than 0.02%/cycle for 5,000cycles. Furthermore, the residual capacity was more than 30% at the 5,000th cycle.

전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구 (Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods.)

  • 조용범;김용철;장상엽;고영태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

비접촉 SPL기법을 이용한 단결정 실리콘 웨이퍼 표면의 극초단파 펄스 전기화학 초정밀 나노가공 (Nanomachining on Single Crystal Silicon Wafer by Ultra Short Pulse Electrochemical Oxidation based on Non-contact Scanning Probe Lithography)

  • 이정민;김선호;김택현;박정우
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.395-400
    • /
    • 2011
  • Scanning Probe Lithography is a method to localized oxidation on single crystal silicon wafer surface. This study demonstrates nanometer scale non contact lithography process on (100) silicon (p-type) wafer surface using AFM(Atomic force microscope) apparatuses and pulse controlling methods. AFM-based experimental apparatuses are connected the DC pulse generator that supplies ultra short pulses between conductive tip and single crystal silicon wafer surface maintaining constant humidity during processes. Then ultra short pulse durations are controlled according to various experimental conditions. Non contact lithography of using ultra short pulse induces electrochemical reaction between micro-scale tip and silicon wafer surface. Various growths of oxides can be created by ultra short pulse non contact lithography modification according to various pulse durations and applied constant humidity environment.