• Title/Summary/Keyword: electrochemical methods

Search Result 562, Processing Time 0.024 seconds

Controllable Patterning of an Al Surface by a PDMS Stamp (PDMS를 이용한 균일한 알루미늄 표면 패터닝 연구)

  • Park, Gayun;Kim, Kyungmin;Lee, Hoyeon;Park, Changhyun;Kim, Youngmin;Tak, Yongsug;Choi, Jinsub
    • Applied Chemistry for Engineering
    • /
    • v.23 no.5
    • /
    • pp.501-504
    • /
    • 2012
  • In this study, etched Al electrodes with ordered arrays of pits and high aspect ratios were successively obtained using a patterned protect layer on the Al surface prepared with soft lithography method. Various methods were applied to fabricate a well ordered protect layer on the Al surface and the difference of etched Al surfaces with and without a protect layer was investigated by using SEM. It was found that the etched Al surfaces were affected by using either a protect layer or a non protect layer. As a result, the Al surface with the well ordered pits could be achieved by protect layer. However, the etched Al with nonuniform pits can be obtained without any protect layers.

The Addition of Carbon Black to Raney Nickel Hydrogen Electrodes for Alkaline Fuel Cells (알칼리 연료전지용 라니니켈 수소극에서 카본블랙의 첨가)

  • Jo, Jang-Ho;Lee, Sang-Gon;Cho, Won-Il;Kim, Young Chai;Yi, Sung-Chul;Lee, Ju-Seong;Moon, Sei-Ki
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.927-933
    • /
    • 1997
  • The effects of carbon black on the electrodes performance and on the structure of the catalyst layer in Raney nickel hydrogen electrodes for alkaline fuel cells were investigated by using electrochemical and nitrogen adsorption methods. The optimum content of carbon black in the catalyst layer of Raney nickel hydrogen electrode was 2wt%. The limiting current density was increased by the addition of carbon black due to the enlargement of gas-liquid interface area. The rate determining step at the limiting current density was supposed to be a step where hydrogen dissolves at gas-liquid interfaces.

  • PDF

Enhanced Electrocatalytic Activity of Platinized Carbon Electrode via NaBH4 Treatment (NaBH4 화학적 처리를 통한 백금화 카본 전극의 촉매반응 향상)

  • Yun, Changsuk;Hwang, Seongpil
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.581-584
    • /
    • 2020
  • The effect of a chemical pretreatment on the surface carbon was investigated using a scanning electron microscope (SEM) and electrochemical methods. Primitive carbon has a reducing power likely due to incompletely oxidized functional groups on the surface. We aim to control this reducing power by chemical treatment and apply for the spontaneous deposition of nanoparticles (NPs). Highly ordered pyrolytic graphite (HOPG) was initially treated with a reducing agent, NaBH4 or an oxidizing agent, KMnO4, for 5 min. Subsequently, the pretreated carbon was immersed in a platinum (Pt) precursor. Unexpectedly, SEM images showed that the reducing agent increased spontaneous PtNPs deposition while the oxidizing agent decreased Pt loading more as compared to that of using bare carbon. However, the amount of Pt on the carbon obviously decreased by NaBH4 treatment for 50 min. Secondly, spontaneous reduction on pretreated glassy carbon (GC) was investigated using the catalytic hydrogen evolution reaction (HER). GC electrode treated with NaBH4 for a short and long time showed small (onset potential: -640 mV vs. MSE) and large overpotential for the HER, respectively. Although the mechanism is unclear, the electrochemistry results correspond to the optical data. As a proof-of-concept, these results demonstrate that chemical treatments can be used to design the shapes and amounts of deposited catalytic metal on carbon by controlling the surface state.

Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

  • Lee, Bo-Ah;Kim, Hae-Jin;Xuan, Yun-Ze;Park, Yeong-Joon;Chung, Hyun-Ju;Kim, Young-Joon
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.512-520
    • /
    • 2014
  • PURPOSE. The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS AND METHODS. The zirconium films were developed on Ti-6Al-4V discs using RF magnetron sputtering method. Surface profile, surface composition, surface roughness and surface energy were evaluated. Electrochemical test was performed to evaluate the corrosion behavior. Cell proliferation, alkaline phosphatase (ALP) activity and gene expression of mineralized matrix markers were measured. RESULTS. SEM and EDS analysis showed that zirconium deposition was performed successfully on Ti-6Al-4V alloy substrate. Ti-6Al-4V group and Zr-coating group showed no significant difference in surface roughness (P>.05). Surface energy was significantly higher in Zr-coating group than in Ti-6Al-4V group (P<.05). No difference in cell morphology was observed between Ti-6Al-4V group and Zr-coating group. Cell proliferation was higher in Zr-coating group than Ti-6Al-4V group at 1, 3 and 5 days (P<.05). Zr-coating group showed higher ALP activity level than Ti-6Al-4V group (P<.05). The mRNA expressions of bone sialoprotein (BSP) and osteocalcin (OCN) on Zr-coating group increased approximately 1.2-fold and 2.1-fold respectively, compared to that of Ti-6Al-4V group. CONCLUSION. These results suggest that zirconium coating on Ti-6Al-4V alloy could enhance the early osteoblast responses. This property could make non-toxic metal coatings on Ti-6Al-4V alloy suitable for orthopedic and dental implants.

Electrochemical Synthesis of Red Fluorescent Silicon Nanoparticles

  • Choi, Jonghoon;Kim, Kyobum;Han, Hyung-Seop;Hwang, Mintai P.;Lee, Kwan Hyi
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.35-38
    • /
    • 2014
  • Herein, we report on the preparation of red fluorescent Si nanoparticles stabilized with styrene. Nano-sized Si particles emit fluorescence under UV excitation, which could be used to open up new applications in the fields of optics and semi-conductor research. Unfortunately, conventional methods for the preparation of red fluorescent Si nanoparticles suffer from the lack of a fully-established standard synthesis protocol. A common initial approach during the preparation of semi-conductors is the etching of crystalline Si wafers in a HF/ethanol/$H_2O$ bath, which provides a uniformly-etched surface of nanopores amenable for further nano-sized modifications via tuning of various parameters. Subsequent sonication of the etched surface crumbles the pores on the wafer, resulting in the dispersion of particles into the solution. In this study, we use styrene to occupy these platforms to stabilize the surface. We determine that the liberated silicon particles in ethanol solution interact with styrene, resulting in the substitution of Si-H bonds with those of Si-C as determined via UV photo-catalysis. The synthesized styrene-coated Si nanoparticles exhibit a stable, bright, red fluorescence under excitation with a 365 nm UV light, and yield approximately 100 mg per wafer with a synthesis time of 2 h. We believe this protocol could be further expanded as a cost-effective and high-throughput standard method in the preparation of red fluorescent Si nanoparticles.

Osteogenic Gene Expression on Anodizing Titanium Surface (양극산화 처리된 타이타늄 표면에서 골형성 유전자 발현)

  • Kim, Won-Seok;Kim, Young-Seok;Jeon, Seong-Bae;Jun, Sang-Ho;Lee, Eui-Suk;Jang, Hyon-Seok;Kwon, Jong-Jin;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the expression of osteogenic genes associated with bone regeneration on anodizing titanium surface. Methods: $20{\times}20{\times}1$ (mm) commercially pure titanium plate was made, one group was pure titanium, second group was punched, and last group was punched and anodized by electrochemical method. Through the osteogenic cell culture model, the expression of extracellular matrix proteins, such as bone morphogenetic protein-2, bone sialoprotein, aggrecan, osteocalcin, Alkaline phosphatase, collagen I had been evaluated by Real-time polymerase chain reaction, and the morphology of growing cells was evaluated by scanning electron microscopy. Results: The attachment of mesenchymal stem cell was even and well-oriented on all Ti surfaces. The osteogene expression was increased on punching groups but, decreased on anodizing surfaces in 3 week samples. Conclusion: Punched anodizing Ti has possibility be using as a dental implant material, but further in vivo study would be needed.

Corrosion and Nanomechanical Behaviors of 16.3Cr-0.22N-0.43C-1.73Mo Martensitic Stainless Steel

  • Ghosh, Rahul;Krishna, S. Chenna;Venugopal, A.;Narayanan, P. Ramesh;Jha, Abhay K.;Ramkumar, P.;Venkitakrishnan, P.V.
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2016
  • The effect of nitrogen on the electrochemical corrosion and nanomechanical behaviors of martensitic stainless steel was examined using potentiodynamic polarization and nanoindentation test methods. The results indicate that partial replacement of carbon with nitrogen effectively improved the passivation and pitting corrosion resistance of conventional high-carbon and high- chromium martensitic steels. Post-test observation of the samples after a potentiodynamic test revealed a severe pitting attacks in conventional martensitic steel compared with nitrogen- containing martensitic stainless steel. This was shown to be due to (i) microstructural refinement results in retaining a high-chromium content in the matrix, and (ii) the presence of reversed austenite formed during the tempering process. Since nitrogen addition also resulted in the formation of a $Cr_2N$ phase as a process of secondary hardening, the hardness of the nitrogen- containing steel is slightly higher than the conventional martensitic stainless steel under tempered conditions, even though the carbon content is lowered. The added nitrogen also improved the wear resistance of the steel as the critical load (Lc2) is less, along with a lower scratch friction coefficient (SFC) when compared to conventional martensitic stainless steel such as AISI 440C.

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.

Analysis of the Corrosion Behavior According to the Characteristics of Sigma Phase Formed in Super Austenitic Stainless Steel (슈퍼 오스테나이트계 스테인리스강의 시그마상 특성에 따른 부식거동 분석)

  • Kim, Ye Eun;Park, Jin-seong;Cho, Dong Min;Hong, Seung Gab;Kim, Sung Jin
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.203-210
    • /
    • 2020
  • The corrosion behavior of super austenitic stainless steel was studied by examining the characteristics of the sigma phase formed in the steel. A range of experimental and analytical methods was employed, including potentiodynamic polarization tests, critical pitting temperature tests, transmission electron microscopy, and energy-dispersive spectroscopy. Three steel samples with different sigma phase levels were obtained by intentionally adjusting the manufacturing process. The results showed that the corrosion resistance of the samples was strongly dependent upon the size and distribution of the sigma phase precipitated in the samples. The larger the size of the sigma phase, the higher the Mo content in the sigma phase and the higher the depletion level of Mo at the interface between the matrix/sigma phase, the more samples with a coarse-sized sigma phase were susceptible to localized pitting corrosion at the interface. These results suggest that various manufacturing processes, such as welding and the post-heat treatment of the steel, should be optimized so that both the size and fraction of the sigma phase precipitated in the steel are small to improve the resistance to localized corrosion.

Effects of Blasting and Acidic Treatment on the Corrosion Characteristics of Dental Implant Fabricated with Cp-Ti and Ti-6Al-4V Alloy (Cp-Ti와 Ti-6Al-4V 합금으로 제조된 치과용 임플란트의 부식특성에 관한 블라스팅과 산세처리의 영향)

  • Moon, Young-Pil;Choe, Han-Cheol;Park, Su-Jung;Kim, Won-Gi;Ko, Yeong-Mu
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.4
    • /
    • pp.190-197
    • /
    • 2006
  • The effects of blasting and acidic treatment on the corrosion characteristics of dental implant fabricated with Cp-Ti and Ti-6Al-4V alloy have been researched by using electrochemical methods. The fabricated implants were cleaned and sandblasted by $Al_2O_3$ powder and then acidic treatment was carried out in nitric acid solution. The surface morphology were observed using scanning electron microscope. The corrosion behaviors were investigated using potentiosat and EIS in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The potentio-dynamic test in 0.9% NaCl indicated that the corrosion potential of blasting and acidic treated implant was lower than that of non treated implant, but current density was higher than that of non treated implant. From the cyclic potentiodynamic test results of Ti implant, the passivation current density of blasting and acidic treated implant slightly higher than that of non treated implant. From A.C. impedance test results in 0.9% NaCl solution, polarization resistance($R_p$) value of blasting and acidic treated implant was lower than that of non treated implant. In case of blasting and acidic treated implant surface, the pits were observed in valley and crest of implant surface.