• Title/Summary/Keyword: electrochemical absorption

Search Result 171, Processing Time 0.021 seconds

Polypyrrole Film Studied by Three-Parameter Ellipsometry

  • 김동래;이덕환;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.8
    • /
    • pp.707-712
    • /
    • 1996
  • Growth and changes of electronically conducting polypyrrole (PPy) in the form of thin films polymerized on metal electrodes were investigated by electrochemical and in situ three-parameter ellipsometry methods at the wavelength of 632.8 nm. Although the optical equations produced multiple sets of solution, it was possible to determine a unique set of thickness and the optical constants of a film by auxiliary measurements and/or physical reasoning. The changes in the thickness and the optical properties of the polymers during polymerization and electrochemical oxidation/reduction was successfully followed by the three-parameter ellipsometric technique. The optical properties of the polymers continuously changed as the film grew. The imaginary part of the refractive index of polypyrrole seemed to be dominantly determined by the existence of an absorption band around the visible range.

RF-Sputted Vanadium Oxide Thin Films:Effect of Oxygen Partial Pressure on Structural and Electrochemical Properties

  • Park, Yong Jun;Park, Nam Gyu;Ryu, Gwang Seon;Jang, Sun Ho;Park, Sin Jong;Yun, Seon Mi;Kim, Dong Guk
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1015-1018
    • /
    • 2001
  • Vanadium oxide thin films with thickness of about 2000 $\AA$ have been prepared by radio frequency sputter deposition using a V2O5 target in a mixed argon and oxygen atmosphere with different Ar/O2 ratio ranging from 99/1 to 90/10. X-ray diffraction and X-ray absorption near edge structure spectroscopic studies show that the oxygen content higher than 5% crystallizes a stoichiometric V2O5 phase, while oxygen deficient phase is formed in the lower oxygen content. The oxygen content in the mixed Ar + O2 has a significant influence on electrochemical lithium insertion/deinsertion property. The discharge-charge capacity of vanadium oxide film increases with increasing the reactive oxygen content. The V2O5 film deposited at the Ar/O2 ratio of 90/10 exhibits high discharge capacity of 100 ${\mu}Ah/cm2-{\mu}m$ along with good cycle performance.

Ordered CdS nanorods- organic hybrid solar cells

  • Kang, Yoon-Mook;Kim, Dong-Hwan
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.32-36
    • /
    • 2005
  • We studied the optoelectronic properties of hybrid solar cells formed by mixing cadmium sulfide [CdS] nanorods with a conjugated polymer, poly-2-methoxy, 5-[2'-ethy[hexyloxy]-1,4-p-phenylenevinylene[MEH-PPV]. CdS nanorods were grown vertically on Ti substrates by electrochemical deposition through a porous alumina template. Absorption spectrum of the composite layer was the same as the superposition of the absorption spectrum of each individual layer. The photoluminescence signal from MEH-PPV film was reduced as a result of the mixing. The energy conversion efficiency of MEH-PPV improved from $0.0012\%$ to about $0.60\%$ when combined with the vertically aligned CdS nanorods.

  • PDF

Effect of Electrolyte Concentration on Water Permeation in Protective Coatings (방식도막에 있어서 물의 침투에 대한 전해질 용액의 영향)

  • 박진환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.206-212
    • /
    • 1998
  • The water permeation in protective coatings, which may greatly influence the corrosion protective property of these coatings, was studied using the electrochemical impedance spectroscopy technique. During the absorption of water in protective coatings immersed in electrolyte solution, the change of coating capacitance with concentration of electrolyte was determined from impedance measurements. When water absorption or desorption of coatings occured by exposing the coatings to electrolyte solutions of different concentration, increase in impedance caused by desorption of water was found to be higher in the case of thicker film. The amount of water absorbed in coatings changed with concentration of electrolyte. The water taken up in coatings from the solution of lower electrolyte concentration was deserted by contact with the solution of higher concentration. The uptake of water in protective coatings varied depending on the type of coating ingredient especially binder.

  • PDF

The Relation between Hydrogen absorption and Expansion behavior in the Rolled Plate (압연가공판재의 수소저장과 팽창거동과의 관계)

  • Jung, Young-Guan;Kim, Kyoung-Hoon;Lee, Keun-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.12 no.2
    • /
    • pp.121-128
    • /
    • 2001
  • In order to study the relation between expansion of the specimen and the hydrogen absorption rate, thin palladium plates with cold rolling were used. Thin palladium plates were hydrogenated in the 0.1mol $H_2SO_4$ electrolyte by electrochemical method. The expansion behavior on hydrogen absorbing can be obtained by X-ray diffraction analysis and by micrometer measurement It is noted that the expansion rate of Palladium specimens in thickness direction is larger than in length and width direction. The lattice constants increase quickly with increasing hydrogen absorbing rate up to 0.5, but above the rate they keep constant. Also the clues for plastic deformation, such as slip lines and voids, were observed in abundantly even though the plates were hydrogenated once.

  • PDF

Manipulation of Absorption Maxima by Controlling Oxidation Potentials in Bis(tridentate) Ru(II) N-Heterocyclic Carbene Complexes

  • Kim, Hyeong-Mook;Jeong, Daero;Noh, Hee Chang;Kang, Youn K.;Chung, Young Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.448-456
    • /
    • 2014
  • A series of seven Ru(II) complexes bearing NHC ligands have been synthesized. The electronic structures of these complexes were analysed by spectroscopic and electrochemical methods and further examined by theoretical calculations. Data show that absorption maxima are dependent on the HOMO level rather than the HOMO-LUMO gaps.

Synthesis and Characterization of New Macroporous SnO2 Foams

  • Choi, Moon-Hyung;Paek, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.1388-1390
    • /
    • 2013
  • Macroporous $SnO_2$ foam was successfully synthesized via a simple soft-chemical route by hybridization between alkylamine and tin(IV) oxide. According to X-ray diffraction (XRD) analysis, the as-prepared $SnO_2$ foam had a highly ordered lamella structure along the crystallographic c-axis, which transformed to a rutile phase after thermal treatment at $300^{\circ}C$. X-ray absorption spectroscopy (XAS) at the Sn K-edge revealed that $SnO_2$ particles in the hybrid material maintained their nanosized structure after hybridization with alkylamine. Scanning electron microscope (SEM) images clearly showed that the as-prepared $SnO_2$ foam had a macroporous structure. This synthetic route can be extended to the development of open frameworks with good electrochemical properties in battery applications.

Compressive Strength Property of Cement Matrix According to the Type of Lightweight Aggregate (경량골재의 종류에 따른 시멘트 경화체의 강도 특성 평가)

  • Pyeon, Myeong-Jang;Jeong, Su-Mi;Kim, Ju-Sung;Kim, Ho-Jin;Park, Sun-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.111-112
    • /
    • 2022
  • Lightweight aggregate is a porous material that has a lower density than natural aggregate and is a lightweight construction material. Lightweight Aggregate has a suitable purpose because it is effective in reducing the heavy unit mass in high-rise buildings. However, since lightweight aggregate has weak strength and high water absorption compared to natural aggregate, it is difficult to control the quality of concrete. Although lightweight aggregate has disadvantages such as high water absorption, it is expected that the demand for lightweight aggregate concrete will continue to use in the future because the advantage of being able to reduce the weight of concrete is greater. In this study, we conducted an experimantal study on the compressive strength property of cement matrix according to the type of lightweight aggregate.

  • PDF

A Study on Electrochemical Characteristics Aluminum Multi Matrix Compound (Al-MMC) of Neutron Absorber Material

  • Lee, Jung Hwan;Lee, Yunju;Yoo, Seung Chang;Kim, Seunghyun;Kim, Ji Hyun
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.11a
    • /
    • pp.179-180
    • /
    • 2018
  • Al - MMC, used as a neutron absorber, shows pitting corrosion and/or galvanic corrosion in 3.5wt.% NaCl solution. If pitting corrosion penetrates the core, neutron absorption performance could be affected. Galvanic corrosion was observed between Al 5052 and Al 1070, and pitting corrosion was observed around $B_4C$.

  • PDF

A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids (LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.