• 제목/요약/키워드: electrification

검색결과 235건 처리시간 0.022초

Consideration of Technical Direction of Software Defined Vehicle Integration with C-ITS based on the analysis of In-Vehicle Infotainments (차량 인포테인먼트 아키텍처 분석 기반 향후 협력 지능형 교통 체계와 SDV 연동 방향성에 대한 고찰)

  • Joon-Young Kim;Young-Eun Kim;Won-Jun Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제19권1호
    • /
    • pp.149-156
    • /
    • 2024
  • The increased intelligence and speed of vehicle infotainment, whose main purpose was emergency and external communication, is showing the potential for application to various services such as navigation and autonomous driving. In particular, functionality for linking external devices and infrastructure is being strengthened due to advances in communication and networks. Under this trend, it is necessary to consider the direction of linkage with the cooperative intelligent transportation system (C-ITS) for advanced vehicle services and driving. In addition, in the case of automobiles, future vehicle development concepts are being established based on the concept of software-defined vehicles (SDVs) in line with the trend of electrification beyond telematics and infotainment advancements, and such SDV linkage must be considered at the same time. In this paper, we consider the future direction of ITS and SDV linkage based on analysis of vehicle infotainment structure. First, for this purpose, we analyze the existing vehicle infotainment structure and architecture, and also present the structure of the SDV linked to it. Based on this, analysis and implications are drawn on the possibility of applying and linking standard-based C-ITS services with SDV devices.

Analysis of the Utilization Characteristics of Electrical Power and Equipments on the Farms (농촌의 전력및 전기기기의 이용특성분석)

  • 박승우;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제17권4호
    • /
    • pp.3943-3955
    • /
    • 1975
  • The purposes of this study are to evaluate the utilization characteristics of electrical power consumption, to grasp the present trends in the use of electrical equipments, to estimate the demand factor and load factor being held, and to evaluate the efficiency of electical uses for the recently electrified farms cultivating paddy rice. For the purposes, 109 sample farms located in eleven villiages electrified in six different years from 1968 to 1973, were chosen at random and investigated on 35 items concerning to electrical uses and wiring systems. The survey was carried out in 1975, in the vinicity of Suweon city. The results are summarized as follows: i) The average annual power consumption on sample farms is considered to be low, being 242.9 Kwh. in 1974, and varied according to the different electrified year and size of cultivated land, respectively. It has significant positive correlation to the area of farm, too. ii) Between the number of year of electrical uses and the power consumption, there is very significant positive correlation, which could be expressed as Y=43.041+16.108 X, where X represents the number of years of electrical uses. The annual increment of power consumption is much greater at the beginning of the electrification than that at the later years, its average being approximately 20 percent. However, it is recommended that any estimation of long-term increments should be carefully investigated. iii) The monthly power consumption varies considerably throughout a year, in which the heaviest farm load occurs in November. Observing the seasonal variation of consumption, the winter-time is the heaviest season while the summer is the lowest. The result implies house lighting is chief contribution to the present electrical consumption on the farms. Comparing the variation of monthly consumption ratios between the sample farms and industries, the electrical uses on the farms are independant of the industrial uses, and further, the agricultural uses are of inverse pattern to the farms from the results that there is negative correlationship between them, iv) The number of electrical equipments used on the farms are occupied chiefly by lighting sources. Next to the lighting sources, household appliances of small quantity and some motors are used. The mean electrical quantity is about 1, 127.4 watt, which corresponds to about 37.6 per cent to the contracted quantity. The composition of quantity is chiefly occupied by the electrical motor of about 1.5 hp., single-phased. The number of the annual utilization hours of each equipment is tabulated in Table IV-5. In contradiction to the high utilization of lighting sources and small household appliances, the motor is poorly used for approximately 22 hours in a year. v) More than 55 per cent of farms want to purchase new electrical equipments such as small household appliances and electrical motors in their number. The impulse of purchasing such items is stimulated by the contacts to the mass media and their knowledge on such equipments. Consequently, the increase of electrical uses could be prompted by such trials as education and demonstration. vi) The demand and load factors on the farms vary considerably according to the greater variation of the power consumption, daily or monthly. The daily demand factor is 22.4 per cent and load factor 18.6 per cent, while the annual demand factor is 1.3 per cent and load factor 70 per cent approximately. Therefore, the low efficiency of construction cost requires re-evaluation of the present contracted quantity of 3 Kw. or increase of electrical uses. vii) The electrical energy on the farms devoted chiefly to lighten the farm residences does not contribute to the farm incomes. Consequently, the cost of electrical consumption presses considerably upon the farm economy. Therefore, there is great need to build up the electrical uses on the farms through the development of new works and techinques to utilize any electrical equipments on the production of farm products. Further more, such the development should be related to increase the actual income of the farm consumers.

  • PDF

Impacts of Energy Tax Reform on Electricity Prices and Tax Revenues by Power System Simulation (전력계통 모의를 통한 에너지세제 개편의 전력가격 및 조세수입에 대한 영향 연구)

  • Kim, Yoon Kyung;Park, Kwang Soo;Cho, Sungjin
    • Environmental and Resource Economics Review
    • /
    • 제24권3호
    • /
    • pp.573-605
    • /
    • 2015
  • This study proposed scenarios of tax reform regarding taxation on bituminous coal for power generation since July 2015 and July 2014, estimated its impact on SMP, settlement price, tax revenue from year 2015 to year 2029. These scenarios are compared with those of the standard scenario. To estimate them, the power system simulation was performed based on the government plan, such as demand supply program and the customized model to fit Korea's power system and operation. Imposing a tax on bituminous coal for power generation while maintaining tax neutrality reducing tax rate on LNG, the short-term SMP is lowered than the one of the standard scenario. Because the cost of nuclear power generation is still smaller than costs of other power generation, and the nuclear power generation rarely determines SMPs, the taxation impact on SMP is almost nonexistent. Thus it is difficult to slow down the electrification of energy consumption due to taxation of power plant bituminous coal in the short term, if SMP and settlement price is closely related. However, in the mid or long term, if the capacity of coal power plant is to be big enough, the taxation of power plant bituminous coal will increase SMP. Therefore, if the tax reform is made to impose on power plant bituminous coal in the short term, and if the tax rate on LNG is to be revised after implementing big enough new power plants using bituminous coal, the energy demand would be reduced by increasing electric charges through energy tax reform. Both imposing a tax on power plant bituminous coal and reducing tax rate on LNG increase settlement price, higher than the one of the standard scenario. In the mid or long term, the utilization of LNG complex power plants would be lower due to an expansion of generating plants, and thus, the tax rate on LNG would not affect on settlement price. Unlike to the impact on SMP, the taxation on nuclear power plants has increased settlement price due to the impact of settlement adjustment factor. The net impact of energy taxation will depend upon the level of offset between settlement price decrease by the expansion of energy supply and settlement price increase by imposing a tax on energy. Among taxable items, the tax on nuclear power plants will increase the most of additional tax revenue. Considering tax revenues in accordance with energy tax scenarios, the higher the tax rate on bituminous coal and nuclear power, the bigger the tax revenues.

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -4. Effect of Killing Methods on Rigor Index and Breaking Strength of Muscle- (넙치(Paralichthys olivaceus)육의 사후 조기 변화 -4. 치사 방법이 육의 사후 경직도와 파괴 강도에 미치는 영향-)

  • CHO Young-Je;LEE Nam-Geoul;KIM Yuck-Yong;KIM Jae-Hyun;CHOI Young-Joon;KIM Geon-Bae;LEE Keun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제27권1호
    • /
    • pp.41-46
    • /
    • 1994
  • This study was undertaken to clarify the effect of killing methods on physical and rheological changes of plaice, Paralichthys olivaceus muscle at early period after death. Plaices killed by the four different methods(1. spiking at the brain instantly. 2. drowning in air. 3. dipping in 1,000ppm ethylaminobenzoate dissolved sea water as an anesthetic. 4. electrifying in sea water.) were stored at $5^{\circ}C$, and the rigor-index and breaking strength through storage were monitored. The longest onset time of rigor-mortis and full rigor was in the samples killed by dipping in sea water with dissolved anesthetic among all samples, where rigor-mortis began at 20hrs after killing and maximum tension was attained after 56hrs. However, in the cases of plaice electrified in sea water or drowned in air, the onset of rigor-mortis began just after killing and maximum tensions were attained after 9hrs and 13hrs, respectively. The level of breaking strength in the muscle of fish killed by spiking the brain instantly was $950.30{\pm}50.23g$, immediately after killing. The value and time reached around the maximum breaking strength for each of the samples were $1,230.60{\pm}30.32g$ and Ohr (immediately after killing) for samples killed by electrifying in sea water, $1,235.83{\pm}35.37g$ and 2.5hrs for drowning samples, $1,186.29{\pm}55.90g$ and 10hrs for spiking samples, and $1,189.67{\pm}50.32g$ and 15hrs for samples dipped in anesthetic, respectively. From the results above, it could be concluded that electrification in sea water is the most effective method in accelerating rigor-mortis and shortening times of reaching the maximum breaking strength of fresh plaice flesh of all the killing methods at early periods after death, whereas dipping in sea water treated with anesthetic was the most effective way in delaying those changes.

  • PDF

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.