• Title/Summary/Keyword: electrical test

Search Result 7,388, Processing Time 0.032 seconds

Analysis and improvement of transfer power capability considering movable load charging of EV (전기자동차 충전부하의 이동성을 고려한 전송 전력량의 해석 및 개선)

  • Kim, Deok Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.762-767
    • /
    • 2017
  • This paper presents an analysis for improving the power transfer capability in transmission lines caused by the movable load charging of electric vehicles (EVs). EVs are expected to be used more widely and replace gas fuel vehicles in the near future due to the shortage of fossil fuels and for environmental preservation. Movable load charging of EVs could lead to the convergence of transferred power flow and overloading conditions in transmission lines in a specific area of a power system, which is conventionally based on estimated fixed load capability. To analyze these conditions, the New England Test System was divided into four regions based on the load characteristics, and different charging scenarios were considered. In these scenarios, the regional power load was highly increased to 31% based on the standard charging capacity of an EV. As a solution to the overloading problem of transmission lines, a TCSC was installed serially on the overloaded line to directly control the transferred power under limited line capability (100% load capability). The simulation showed that the application of a few TCSCs could efficiently and economically control the line capability problem caused by movable load charging of EVs.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

DEVELOPMENT OF A PERSIMMON HARVESTING SYSTEM

  • Kim, S. M.;Park, S. J.;Kim, C. S.;Kim, M. H.;Lee, C. H.;J. Y. Rhee
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.472-479
    • /
    • 2000
  • A persimmon harvesting vehicle that can be operated in hilly orchards as well as a manipulator that can be used to harvest persimmons located in remote positions in the trees were designed and developed. The vehicle could be operated with keeping balanced position in an inclined field and its working platform could be moved up and down easy to approach fruits in a remote region with the aids of a hydraulic and a electrical and electronics systems. The weight of the vehicle was 927 kg and the center of gravity was located at 427 mm to the inner side from the center of a right driving caterpillar, 607 mm to a rear axle from the center of a front axle, and 562 mm to upward from ground. The automatic level control sensor for leveling the working platform was activated within 14.5 ∼ 16.5 degrees of slope variation. The total length of the manipulator was 1.39 m and weight is 975 g. It was powered by a 12 V geared motor to detach persimmon fruits with a rotational force. The gripper was made of plastic and rubber to increase a frictional force. In a performance evaluation test, static tipping angle, dynamic tipping angle toward front side when the vehicle was moving downward, climbing angle, driving speed of the vehicle were measured or calculated. In persimmon harvesting tests 24.9% of yield was increased by hand picking with the aid of the vehicle and additional 7% of yield were increased when the manipulator was used. Therefore, 99010 of total possible yield was achievable when both of the vehicle and the manipulator were used for the manual persimmon harvesting. Increase in 22.5% of total yield was achieved with the manipulator only.

  • PDF

A Study on the Effects of the Electro-Acupuncture(EA) Stimulation after Global Ischemia(GI) on Changes in Bax and Caspase-3 Expression among Forebrain Apoptosis (뇌허혈 유발 후 전침자극이 전뇌세포사 중 Bax와 Caspase-3 발현 변화에 미치는 영향 연구)

  • Choi, Jung-Hyun;Min, Kyoung-Ok;Kim, Soon-Hee;Kim, Dong-Il;Lee, Sang-Bin;An, Ho-Jung;Kim, Ji-Sung;Choi, Wan-Suk;Kim, Bo-Kyoung;Song, Chi-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.1
    • /
    • pp.59-69
    • /
    • 2010
  • Objectives: The study aims to look into how the application of EA(Electro-acupuncture) in the initial step of ischemic brain injury affects the changes in Bax and Caspase-3 expression among forebrain apoptosis. Methods: It caused GI by using common carotid artery occlusion and conducted the test by dividing into the no applied EA group after 6 hours and 12 hours, the LI 4 EA group that applied EA to LI4, and GV 20 EA group that was applied to GV 20. After that, the following results were obtained by comparing Bax and Caspase-3 expression, which were apoptosis-related factors, with its application time through immunohistochemical staining after extracting brain of each group. Results: According to each group's Bax expression by the application time, the order of expression increase after 6 hours is shown to be the no applied EA group, LI 4 group, and GV 20 group. The stimulation after 12 hours was most lowly expressed in the GV 20 group, and the no applied EA group and LI 4 group showed similar level. Conclusions: EA stimulation in the initial step after ischemia seems to affect positively Bax and Caspase-3 expression that are index of forebrain apoptosis.

Geophysical Imaging of Alluvial Water Table and the underlying Layers of Weathered and Soft Rocks (충적층 지하수면 및 그 하부의 풍화암/연암의 경계면 파악을 위한 복합 지구물리탐사)

  • Ju, Hyeon-Tae;Lee, Chul-Hee;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Although geophysical methods are useful and generally provide valuable information about the subsurface, it is important to recognize their limitations. A common limitation is the lack of sufficient contrast in physical properties between different layers. Thus, multiple methods are commonly used to best constrain the physical properties of different layers and interpret each section individually. Ground penetrating radar (GPR) and shallow seismic reflection (SSR) methods, used for shallow and very shallow subsurface imaging, respond to dielectric and velocity contrasts between layers, respectively. In this study, we merged GPR and SSR data from a test site within the Cheongui granitic mass, where the water table is ~3 m deep all year. We interpreted the data in combination with field observations and existing data from drill cores and well logs. GPR and SSR reflections from the tops of the sand layer, water table, and weathered and soft rocks are successfully mapped in a single section, and they correlate well with electrical resistivity data and SPS (suspension PS) well-logging profiles. In addition, subsurface interfaces in the integrated section correlate well with S-wave velocity structures from multi-channel analysis shear wave (MASW) data, a method that was recently developed to enhance lateral resolution on the basis of CMP (common midpoint) cross-correlation (CMPCC) analysis.

Potential Hazard Classification of Aged Cored Fill Dams (노후 코어형 필댐의 잠재 위해성 유형 분류)

  • Park, DongSoon;Oh, Je-Heon
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.207-221
    • /
    • 2016
  • As greater numbers of fill dams and reservoirs become old, the risks of damage or embankment collapse increases. However, few studies have considered the deterioration and hazard classification of the internal core layers of fill dams. This study reports the results of geotechnical investigations of 13 earth-cored fill dams in Korea, based on no-water borehole drilling, Standard Penetration Test, and 2D and 3D electrical resistivity surveys along with in situ and laboratory testing. High-capacity no-water boring minimized core layer disturbance while providing continuous core sample recovery. The results allow the classification of potential hazards related to the existing core layers based on both visual inspection of the recovered samples and the results of engineering surveys and tests. Four types of potential hazard are classified: locally fluidized core with a high water content, rapid water inflow to a borehole, cores with granular materials, and relatively low stiffness of core. Among these, the locally fluidized core is the most critical hazard that requires remedial action because it is related to the potential internal flow path and internal erosion. The other three hazard types are of medium importance and require careful monitoring and regular inspection. Of note, there was no correlation between age and core deterioration. The results are expected to aid the safe management and potential upgrading of aging cored fill dams.

Implementation and Evaluation of Electroglottograph System (전기성문전도(EGG) 시스템의 개발 및 평가)

  • 김기련;김광년;왕수건;허승덕;이승훈;전계록;최병철;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2004
  • Electroglottograph(EGG) is a signal recorded from the vocal cord vibration by measuring electrical impedance across the vocal folds through the neck skin. The purpose of this study was to develop EGG system and to evaluate possibility for the application on speech analysis and laryngeal disease diagnosis. EGG system was composed of two pairs of ring electrodes, tuned amplifier, phase sensitive detector, low pass filter, and auto-gain controller. It was designed to extract electric impedance after detecting by amplitude modulation method with 2.7MHz carrier signal. Extracted signals were transmitted through line-in of PC sound card, sampled and quantized. Closed Quotient(CQ), Speed Quotient(SQ), Speed Index(SI), fundamental frequency of vocal cord vibration(F0), pitch variability of vocal fold vibration (Jitter), and peak-to-peak amplitude variability of vocal fold vibration(Shimmer) were analyzed as EGG parameters. Experimental results were as follows: the faster vocal fold vibration, the higher values in CQ parameter and the lower values in SQ and SI parameters. EGG and speech signals had the same fundamental frequency. CQ, SQ, and SI were significantly different between normal subjects and patients with laryngeal cancer. These results suggest that it is possible to implement portable EGG system to monitor the function of vocal cord and to test functional changes of the glottis.

Oxidation Characteristic Changes in Insulation Oil Depending upon Storage Environments and Oil Resources (저장 환경 및 원료에 따른 전기절연유 산화특성 연구)

  • Lee, Don-Min;Park, Cheon-Kyu;Ha, Jong-Han;Lee, Bong-Hee
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.495-501
    • /
    • 2016
  • Mineral oil has been widely used as an insulating oil for electrical transformers for a long time, but the necessity of employing new insulation oil such as vegetable oil has been increased due to urgent needs for the biodegradability when it leaks and also for the thermal stability at a higher operation temperature. Although specific periods are required between the production and consumption, there are still short of the data to prove the insulation oils' storage stability depending upon various circumstances and their resources. Thus, this paper demonstrates the insulation oils' oxidation characteristics of both mineral and vegetable oils when each was exposed to different environments for 12 weeks. From this test, some properties including total acid number, water content and dielectric breakdown were changed under specific conditions and resources. Vegetable oils showed higher hydrophilicity and water saturation than those of mineral oils due to their molecular compositions. Under sunlight exposure condition, all insulation oils oxidized and changed their properties when exposing to the direct light, regardless of the resource used.

THE PULP TREATMENT OF IMMATURE PERMANENT TEETH USING PARTIAL PULPOTOMY (Partial pulpotomy를 이용한 미성숙 영구치의 치수 치료 : 증례 보고)

  • Rho, Seung-Chul;Kim, Yong-Soo;Kim, Jung-Wook;Jang, Ki-Taek;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.616-622
    • /
    • 1999
  • The primary objective of pulp treatment is to maintain the integrity and health of the oral tissues. The most important and difficult aspect of pulp therapy is determining the health of the pulp, or its stage of inflammation, so that a decision can be made regarding the best form of treatment. Immature permanent teeth are good candidates for many pulp healing procedures, due to their rich blood supply, which is believed to enhance the pulp's ability to react successfully to various insults. Healing was considered to have taken place when the tooth fulfilled the following criteria: 1. Abscence of clinical symtoms 2. Radiographic evidence of dentin bridge formation 3. No intrapulpal or periapical pathosis was evident radiographically 4. Continued root development and closure of the apex in immature teeth 5. Normal dentin apposition in mature teeth 6. Positive response to electrical pulp test This presents a report of cases in which immature permanent teeth, pulp-exposed by caries or trauma, was treated successfully by partial pulpotomy.

  • PDF

Mechanism of Collector Adsorption on Monazite (Monazite 界面上의 捕集劑 吸着機能에 關한 硏究)

  • Hyung Sup Choi;Ki Up Whang
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.91-95
    • /
    • 1963
  • The basic studies of adsorption characteristics of collector on monazite were made by electrophoretic measurement and by determination of the adsorption of some typical flotation collectors. By above measurements made on monazite, it is concluded that $H^+\;and\;OH^-$ are identified to act as potential determining ions and thus the electrical properties of monazite is controlled by the pH of the solution. Therefore, anionic collectors are adsorbed on positively charged surfaces and cationic collectors on negatively charged surfaces, which in turn controls the effective flotation condition with respective collectors for this mineral. These results have been correlated with its flotation behavior obtained by Hallimond tube test.

  • PDF