• Title/Summary/Keyword: electrical test

Search Result 7,386, Processing Time 0.035 seconds

The Analysis on the Oil Deterioration of Pole-Transformer by Non-Destructive and UV/Visible Method (비파괴 및 비색법에 의한 주상변압기 절연유의 경년열화 분석)

  • 곽회로;남영우;윤영자;권혁일;이동준;송일근;권동진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.115-117
    • /
    • 1995
  • This paper describes the O.T aging analysis by non-destructive electrical and UV/visible method. Non-destructive diagnosis method is tan8 test. Also the new method of the aging analysis, UV/visible method was introduced in this paper and compared with the non-destructive electrical method. The UV/visible test could be useful method for the O.T aging electrical diagnosis such as non-destructive electrical method.

  • PDF

Electrical and mechanical properties of elastomer epoxy by addition of liquid elastomer (엘라스토머 첨가량에 의한 탄성에폭시의 기계 및 전기적 특성)

  • Kim, Eung-Kwon;Yoon, Byeong-Don;Kang, Chun-Gi;Park, Dae-Hee;Song, Joon-Tae;Lee, Kwan-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.259-260
    • /
    • 2008
  • In this paper, we fabricated elastomer epoxy specimens by added liquid elastomer to improve the mechanical and electrical properties instead of previous high-voltage epoxy materials. As increased additive contents, glass transient temperature (Tg) was continually decreased in DSC (differential scanning calorimetry). Among specimens, 15 phr sample showed the mechanical and electrical properties similar of high-voltage epoxy in modulus, break-down and arc test. From the optimized condition of elastic epoxy, we confirmed a chance of application for high-voltage materials and power electrical instruments.

  • PDF

Implementation of a Lagragian Relaxation Based Unit Commitment Scheduling (Lagrangian Relaxation 방법에 기초한 전기 기동 정지 계획의 구현)

  • Nam, Y.W.;Kim, S.S.;Jung, H.S.;Han, T.K.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1003-1005
    • /
    • 1998
  • We present the implementation of a Lagrangian Relaxation based large scale thermal Unit Commitment problem. The problem is decomposed into thermal subproblem by using Lagrangian multipliers. The thermal subproblem is solved by using dynamic programmmg. we perform a numerical test using the thermal system of KEPCO over a week (168 hours) period. The programming language used for the test program is C. The result is compared with the priority list method.

  • PDF

Evaluation of the Electrical Resistance between ITO/black interlayer/Bus electrodes in a Plasma Display Panel (플라스마 디스플레이 패널에서 ITO/black interlayer/Bus 전극 간의 전기저항 평가)

  • Moon, Cheol Hee
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.2
    • /
    • pp.97-104
    • /
    • 2008
  • Black interlayer was introduced into between ITO and Bus electrodes to enhance a bright room contrast ratio of a plasma display panel. To measure the electrical resistance of the black interlayer, we designed two test patterns, type I and type II, of which type II pattern was successful. Using type II test pattern, the electrical resistance of the black interlayer was measured to be $300{\Omega}$ for $2{\mu}m$ thickness case and infinitely high for 4, $6{\mu}m$ thickness. This result shows that electrical resistance of the black interlayer in the ITO/black interlayer/Bus electrodes structure is a critical parameter which determines the electrical characteristics of the PDP.

Experimental Research on Basic design and protection of High-$T_c$ Heater Triggered Switch in Liquid Helium

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Chang, Ki-Sung;Na, Jin-Bae;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.13-17
    • /
    • 2008
  • This paper presents experimental and characteristic analysis of hgh-$T_c$ eater-triggered witch using coated conductor (CC) in liquid and gas helium. The high temperature superconducting insert coil which can be installed in a low temperature superconducting (LTS) magnet has been proposed and researched to generate higher magnetic field for MR. Since CC could be an attractive option for HTS insert, it is important to research he characteristics of heater-triggered switch employing CC. We performed the heater test and constructed simulation model using finite element method (FEM.) We performed a protection test and observed normal zone propagation (NZP) signals to evaluate the witch with protection of magnet.

A Profile Analysis about Thermal Life Data of Electrical insulating materials at Accelerated Life Test

  • Bark, Shim-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.12
    • /
    • pp.1814-1819
    • /
    • 2010
  • Since 1987, when statistical analyzing guide for thermal life test of Accelerated Life Test(ALT) was proposed as ANSI/IEEE Std 101, this guide has been used widely for many experiment data. Shim(2004) had done Monte Carlo simulation to compare life of two different systems or materials, based on statistic values obtained from ANSI/IEEE Std 101 data. In this study, a profile analysis is proposed for comparing life of two different systems or materials, and some examples using pre-existing data are given.

Evaluation on the radio influence voltage of ${7^1/2}$ pin type domestic insulators (국산 핀애자의 라디오 방해 전압(RIV) 평가)

  • 양배덕
    • 전기의세계
    • /
    • v.25 no.6
    • /
    • pp.65-68
    • /
    • 1976
  • For the RIV characteristics test of power apparatus, an indoor measuring system of radio influence voltage was set up and by means of this measuring unit SIV characteristics on the 7$^{1}$2/" pin-type domestic insulators were examined. According to the test data, RIV values of all the test pieces exceeded the maximum permissible level at 10kV applied voltage. The electrical resistivity of domestic semi-conductive glaze as good as importedone but un-uniformity of coating is turned out to be a main cause of failure.lure.

  • PDF

Implementation of D-algorithm by using PROLOG (PRLOG에 의한 D-algorithm의 구현에 관한 연구)

  • 김명기;문영덕
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.3
    • /
    • pp.87-94
    • /
    • 1986
  • This paper introduce a new test generation method based on built-in data base which is suitable for generating of test set by using PROLOG language. The program presented in this paper deals with all the information required for fault detection from the rules describing output signals and internal signals. Example shows the validity of proposed PROLOG program which results in a effective generation of test set comparable to the conventional D-algorithm.

  • PDF

Psophometeric Noise Voltage of Telecommunication Lines and Test methods (통신회선의 잡음전압 기준 및 측정법)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.617-620
    • /
    • 2001
  • The protection of communication lines against harmful effects from electricity lines is very important with the rapid development of communications network. This paper is introduced the reference of noise voltage and the test methods of foreign countries. Further we will also present study measurement equipment for telecommunications noise voltage and circuit noise phenomenon.

  • PDF

Reliability Analysis of Auto-Connector in Use-condition (사용 조건하에서의 자동차용 커넥터 신뢰성 분석)

  • 김종걸;김진환
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.129-136
    • /
    • 2004
  • Environmental factors for automotive consist of temperature, humidity, vibration(sine & random), gas, an electrical load and so on. These environmental factors are impressed in a automotive. Dependability is essential requirement in many electronic parts. Among components of automotive, the connector connecting electrical signals is one of the most important parts. Automotive -connector is inspected according to each manufacturer's test standard in which dependability should be considered. This paper aims to verify that current test standard is suitable for dependability, and present an inductive life test for automotive connector based on the field data in use-condition.

  • PDF