한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
/
pp.281-287
/
2003
A Natural cavities were found at shallow depth during construction of a huge bridge in Moon-Kyung, Korea. The distribution patterns of cavities in the Moon-Kyung limestone were investigated carefully with a supplementary field job such as a structural geological survey, a geophysical survey, and a rock mechanical test in laboratory or field. A structural geological mapping produced a detail geological map on this area. It suggested that there were three faults in this area, and these faults had an influence on the mechanism of natural cavities. Among many kinds of geophysical surveys, an electrical resistivity prospecting was applied firstly on the specific area that was selected by results from the geological survey. Many evidences for cavities were disclosed from this geophysical data. Therefore, a seismic tomography was tested on the target area, which was focused by results from the electrical resistivity prospecting and was believed to have several large cavities. A distinct element numerical simulation using the UDEC was followed on the target area after completing all of field surveys. Data from field tests were directly dumped or extrapolated to numerical simulations as input data. It was verified from numerical analysis that several natural cavities underneath the foundation of the bridge should be reinforced. Based on the project result, finally, most of foundations for the bridge were re-examined and the cement grouting reinforcement was constructed on several foundations among them.
Although the problem of seawater intrusion at the coastal aquifer was recognized before over one hundred years at the coastal aquifer, much groundwater keep on being salinitized by several reasons such as groundwater exhaustion, coastalline change, and human activities. The horizontal and vertical electrical soundings and geostatistical methods were used to define the local characteristics of saltwater intrusion and to estimate the saltwater interface in the southeastern area of the Pusan City. The 24 points of the Schlumberger vertical electrical soundings(VES) to loom depth and the 2 lines of dipole-dipole horizontal soundings are peformed. The resistivity data have lognormal distributions. The horizontal extents of saline water intrusion were estimated from the inversion of horizontal prospecting data. Lognormal ordinary kriging is used in A-A' resistivity profiles on May and July because the data have stationary models in semivariograms. Lognormal IRF-k kriging is used for the isopleth maps using vertical resistivity data. The 10 ohm-m resistivity line on the isopleth maps of 21m, 30m, 50m, and 70m depth using resisitivity data measured in July is sifted to the east, cpomparing that of the isopleth maps measured in May. The kriged vertical and horizontal resistivity isopleth maps suggested that the geostatistical methods can be used to define the variation of earth resistivity distribution at the saltwater interface.
This study is a model analysis for an effective application of the geophysical prospecting to the investigation of geological structures or useful resources, and the purpose of it is to research a property of the electrical resistivity prospecting, especially by using a Three-Point electrode array method. In using the Three-Point electrode array method, it is theoretically assumed to choose the infinite for a distance between the two current electrodes, however it is impossible in applying to the practical field prospecting. Therefore this study was conducted for determination and presentation of a minimum appropriate distance between the two current electrodes by making a study on prospecting effect in the variation of distance between both the electrodes. In case that the ratios of the distance between the two current electrodes to that between the two potential electrodes are respectively chosen for 40, 400, 5,000, the experimental data of this study showed that the minimum appropriate distance between the two current electrodes is forty times as much as that between two potential electrodes. In order to make clear a problem about prospecting depth which is essential to the data processing, it had been chosen equally to the distance between two potential electrodes. As a result of it, it was shown that the anomaly is appeared along the position of an assumed ore body. Consequently it was found out that the prospecting depth of the Three-Point electrode array method is the same as the distance between the two potential electrodes. From the model experiment on the sheeting ore body(or linear structure) of horizontal, dipping of $30^{\circ}$, $60^{\circ}$ and vertical on the basis of above experimental condition, it was found out that the position and dip of assumed ore body could be inferred from the aspects of the equiresistivity curve. In consequence of performing out the simultaneous Normal and Reversal electrode movement, it was shown that the electrode movement of the Reversal forms the anomaly more clearly than that of Normal when the sheeting ore body is situated obliquely, therefore it could be ascertained that the electrode movement have to be performed simultaneously in the manner of Normal and Reversal. It was also exhibited that the aspect of the equiresistivity curve forms symmetrically when an assumed ore body (or linear structure) is situated horizontally or vertically, that is, symmetrically, and moreover that the aspect of the equiresistivity curve forms unsymmetrically when an assumed ore body (or linear structure) is situated obliquely. On the basis of these experimental analysis it is thought that it can be inferred from the aspect of equiresistivity curve whether an assumed ore body is obliquely situated or not.
To estimate presumptive local ground subsidence area near Abandoned Under ground Coal Mine(AUCM) at Samcheok city in Korea, the geological properties of existing ground subsidence area and the geophysical prospecting data were analyzed using GIS. The electrical resistivity survey and seismic reflection survey database were constructed from investigation reports and factors which are related with ground subsidence such as geological map, topological map, land use map, lineament map, groundwater level, RMR (Rock Mass Rating), mining tunnel map and slope database were constructed also to make a comparative study of each parameters. As a result of the spatial analysis of existing ground subsidence area, 9 major factors causing ground subsidence were extracted and a connection between the structure of underground and the ground subsidence was determined from the analysis of geophysical prospecting data. The estimation of presumptive ground subsidence area was performed using the correlation between the result from neural network analysis of 9 factors and the scrutiny of geophysical prospecting data.
현재까지 양산단층대 노출 구간의 전기비저항탐사를 통하여 단층대와 전기비저항 값을 부분적으로 비교 분석하는 몇몇 연구들이 수행되었다. 그러나 양산단층대과 같은 대규모 단층 내에서 단층면을 직접 관찰하기 어려울 뿐만 아니라 단층핵부의 풍화작용으로 인해 단층운동 특성을 직접적으로 관찰하기가 쉽지 않다. 본 연구에서는 양산단층대 남부 언양지역의 전기비저항탐사 및 미소지형 측량과 지질조사 결과를 종합적으로 해석하여 양산단층의 위치, 발달양상과 단층핵 구간과 이를 중심으로 발달하는 단층 손상대의 지하 발달 특성을 파악하였다. 전기비저항탐사에 의하면 북북동 내지 북동 방향으로 발달하는 저비저항 이상대가 확인되었으며, 전기비저항탐사, 미지형 측량 및 야외 지질조사 결과를 종합할 때, 양산단층대는 하나의 단층핵 또는 파쇄대가 아닌 최소 3~5매의 단층핵, 단층 손상대 또는 파쇄대가 복합적으로 발달하는 것으로 밝혀졌다.
In Korea, ground water exploration by the electric method as a major prospecting tool has been carried out mainly in alluvial deposits, So it is considered to be important to understand the principle concerning the electrical and hydrological properties of alluvium. Factors which affect on the electrical and hydrological properties of alluvium were investigated. Major elements in ground water exploration are porosity and dermeability for most alluvial deposits with exceptions in some particular areas. Much water yield can be expected where alluvial materials have large porosity and small particle size while large particle size in necessary for good permeability. Problem is to locate the points which have comparatively large porosity and good permeability at a time. It is known that electrical resistivity method is proved useful to solve the above problem. The conclusion is: Localities which have greater alluvium thickness(7 to 10m) and 200 to 500 ohm -m of real resistivity value are suitable for well site in alluvial deposits in Korea where alluvium thickness is comparatively small(less than 10m in generaa) and bedrock formations are mainly composed of granite gneiss and granite.
토양 및 지하수의 오염이 사회적으로 심각한 문제로 대두되면서, 복원대책을 위한 조사 방법으로서 물리탐사 기술이 도입되고 있다. 최근의 물리탐사 기술은 컴퓨터를 비롯한 디지털기술의 발달에 힘입어 측정 및 해석기술이 발전함에 따라 짧은 시간에 대량의 데이터를 취득할 수 있으며, 신뢰성이 높은 해석결과를 얻을 수 있게 되었다. 또한 지반 가시화 기술로 탐사결과를 보다 알기 쉽게 영상화할 수 있게 되어, 오염지반의 조사뿐만 아니라 정화과정의 모니터링 등에 널리 사용되고 있다. 본문은 쓰레기 매립지를 대상으로 전기비저항탐사 및 전자탐사를 실시하고, 탐사결과를 이용하여 매립지의 오염특성 평가를 위한 물리탐사의 적용성에 대해서 검토했다. 그 결과 전기비저항탐사 및 전자탐사를 통하여 매립장내의 오염분포 및 침출수의 유동경로 등에 유용한 정보를 얻을 수 있었다.
중부지역에 존재하는 대규모 석회암층을 통과하는 고속도로가 신설되는 가운데, 일부 교량의 교대 하부 얕은 심도에서 자연 생성된 석회암 공동이 다수 발견됨에 따라. 교대 및 교량의 안정성 확보를 위한 추가 정밀조사가 실시되었다. 정밀구조지질조사를 통해 고속도로 노선을 따른 지질도가 작성되었으며 이를 토대로 전기비저항 탐사가 일부 구간에 대해 실시되었다. 이 결과 석회암 공동의 존재가 의심되는 부분에 대해 국부적 인 탄성파탐사가 수행됨으로써 석회암 공동의 위치 및 규모가 최종 파악되었으며, 일련의 현장조사 및 실험실 시험결과를 이용한 수치해석이 이루어졌다. 수치해석에 의한 교대 및 교량의 안정성 분석 결과, 시멘트 그라우팅에 의한 교량하부 기초의 보강이 제안되었다.
전기비저항 탐사는 가장 널리 사용되는 물리탐사 기술 중의 하나로 지하수 및 지하자원 탐사에 널리 사용되어 왔으나 근래에 들어 단순한 이상대의 확인이 아닌 지하 구조를 영상화하는 것으로 확대, 발전되면서 토목 및 환경 분야에 많은 적용이 시도되고 있다. 본 연구에서는 전기탐사에서 큰 영향을 미치는 지형효과를 보정하는 유한요소 법 알고리즘을 개발하였으며 세 가지 현장 적용 사례를 통하여 토목 및 환경 분야에서의 전기비저항 영상화 기법의 적용 가능성을 입증하고자 하였다. 첫째. 공단조성공사 현장에서 토사층의 두께를 파악하여 토취장 후보지의 개발 가능성 여부를 판단하였고, 둘째, 산악지형에서 시공될 고심도 터널 예정구간내의 파쇄대, 한층과 같은 연약때 등을 파악하여 터널 설계 및 시공에 필요한 지질 정보를 제공하였으며, 셋째, 매립이 완료된 산업 폐기물 처분장에서 오염대의 수평l수직적인 분포 및 폐기물 처분의 최대 심도등을 파악하였다.
전기비저항 탐사는 역사가 깊으며 널리 사용되는 물리탐사 기술 중의 하나로서 최근에는 단순한 이상대의 확인이 아닌 지하 구조를 영상화하는 것으로 확대, 발전되면서 토목 및 환경 분야에 많은 적용이 시도되고 있다. 본 연구에서는 환경 분야에서의 전기비저항 탐사의 응용 가능성을 입증하기 위하여 전주시 소재의 폐기물 처분장에서 10 m 간격의 쌍극자 배열 전기비저항 탐사를 8개의 측선상에서 수행하였다. 자동 측정 소프트웨어를 개발하여 자료를 획득하였으며 자료처리 과정에서 지형 효과를 보정하였다. 처분장 내부는 대단히 낮은 저비저항대가 발달하고 있으며 삼천천 쪽을 제외하고는 처분장 부지와 저비저항대의 분포가 정확하게 일치하였다. 또한 오염물질의 수직적인 분포도 삼천천 방향으로 가면서 그 심도가 계속적으로 깊어진다. 이는 삼천천 쪽을 제외하고는 처분장의 방벽이 오염물질의 확산을 잘 막아주고 있으며 오염물질이 삼천천 방향으로 확산되었을 가능성이 높다는 것을 의미한다. 전기비저항 영상화 기법을 이용하여 오염대의 수평/수직적인 분포, 심도별 오염물질의 발달 경향, 폐기물 처분의 최대 심도등의 유추가 가능하며 이는 환경 분야에서 전기비저항 탐사의 응용 가능성을 입증하는 것이다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.