• 제목/요약/키워드: electrical line contact

검색결과 195건 처리시간 0.021초

WSix 증착에서 공정조건이 contact 저항에 미치는 영향 (Influence of Process Condition on Contact Resistance in WSix Deposition)

  • 정양희;강성준;강희순
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we discuss influence of process condition on contact resistance in WSix deposition process. In the WSix deposition process, we confirmed that word line to bit line contact resistance(WBCR) due to temperature of word line WSix deposition among various process condition split experiment. RTP treatment, d-poly ion implantation dose and thickness was estimated a little bit influence on contact resistance. Also, life time of shower head in the process chamber for WSix deposition related to contact resistance. The results obtained in this study are applicable to process control and electrical characteristics for high reliability and high density DRAM's.

  • PDF

Investigation of the Contact Resistance Between Amorphous Silicon-Zinc-Tin-Oxide Thin Film Transistors and Different Electrodes Using the Transmission Line Method

  • Lee, Byeong Hyeon;Han, Sangmin;Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.46-49
    • /
    • 2016
  • A thin film transistor (TFT) has been fabricated using the amorphous 0.5 wt% Si doped zinc-tin-oxide (a-0.5 SZTO) with different electrodes made of either aluminium (Al) or titanium/aluminium(Ti/Al). Contact resistance and total channel resistance of a-0.5SZTO TFTs have been investigated and compared using the transmission line method (TLM). We measured the total resistance of 1.0×102 Ω/cm using Ti/Al electrodes. This result is due to Ti, which is a material known for its adhesion layer. We found that the Ti/Al electrode showed better contact characteristics between the channel and electrodes compared with that made of Al only. The former showed a less contact and total resistance. We achieved high performance of the TFTs characteristic, such as Vth of 2.6 V, field effect mobility of 20.1 cm2 V−1s−1, S.S of 0.9 Vdecade−1, and on/off current ratio of 9.7×106 A. It was demonstrated that the Ti/Al electrodes improved performance of TFTs due to enhanced contact resistance.

고속전철 주행시 이선현상 모델링 방법에 따른 전도성 노이즈 해석 (Analysis of conducted noise on modeling methods for loss of contact during traction of high-speed rail vehicle)

  • 김재문;김양수;장진영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.72-75
    • /
    • 2008
  • The Electromagnetic Interference(EMI) in railway applications is largely due to doing the power conversion for traction and Auxiliary system on the Highspeed Electric Multiple Unit-400X(HEMU-400X). In order to research on EMI in railway applications, it were included how much the HEMU-400X generates it and it has an effect on the equipments of electric system which resulted from Power Line Disturbance (PLD) phenomenon by the loss of contact during its running. In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

전차선-팬터그래프 사이의 이선현상에 따른 전원외란이 보조전원장치에 미치는 영향 (Effect of power line disturbance on loss of contact between contact wire and pantograph)

  • 김재문;김양수;장진영;김윤명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.179-181
    • /
    • 2008
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated. The analysis of the loss of contact based on Power Simulator program software is performed to develop power line disturbance model suitable for high speed operation. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

  • PDF

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

수서고속철도 전차선로의 설치조건의 따른 집전상태 분석 (Analysis of Current Collect Performance Depending on Installation Condition of Overhead Contact Line in Suseo High Speed Line)

  • 나경민;박영;이기원;조용현;권삼영;박철민
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.727-732
    • /
    • 2017
  • This paper describes the dynamic characteristics depending on installation condition between a pantograph and an OCL (Overhead Contact Line) on a new high speed line in Korea. The current collection performance between the pantograph and the OCL was tested during train operation from Suseo to Jije stations. The current collection performance is evaluated based on the duration of an arc by using an arcing measurement system. The system consists of an optical sensor for measuring the duration of an arc and a camera for monitoring current collection performance. An arcing duration is defined as a percentage of arcing in international standards. This test aims to analyze the locations of repetitive arcing depending on installation conditions of OCLs on a new high speed line in order to use the result as reference data for correct construction and maintenance.

선로변 전차선과 조가선의 전류를 이용한 집전성능 분석 기술 (Analysis of Current Collection Performance using Real-time Measurement of Current for Overhead Contact Line on the Track-side)

  • 박영;신승권;이기원;김재문;김원하
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.573-576
    • /
    • 2013
  • In this paper, analysis method for current collection performance based on real-time current of catenary system is proposed. An innovative method based on track-side of railway system is used for measurement of currents for overhead contact line during the collection with pantograph. The evaluation of a qualitative ratio for current collection performance were conducted using proposed algorithm under various conditions such as laboratory and track-side. To check the validity of our approach, we compared between calculation results from current of contact wire and measurement results from arcing of pantograph using simulator in laboratory conditions. The results show that the behavior of current collection performance were analysis from currents of overhead contact line in AC electric railway system.

고속카메라를 이용한 전차선 압상량 검측 시스템 개발 (Development of an Uplift Measurement System for Overhead Contact Wire using High Speed Camera)

  • 박영;조용현;이기원;김형준;김인철
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.864-869
    • /
    • 2009
  • The measurement of contact wire uplift in electric railways is one of the most important test parameters to accepting the maximum permitted speed of new electric vehicles and pantographs. The contact wire uplift can be measured over short periods when the pantograph passes monitoring stations. In this paper, a high-speed image measurement system and its image processing method are being developed to evaluate dynamic uplift of overhead contact wires caused by pantograph contact forces of Korea Tilting Train eXpress (TTX) and Korea Train eXpress (KTX). The image measurement system was implemented utilizing a high-speed CMOS (Complementary Metal Oxide Semiconductor) camera and gigabit ethernet LAN. Unlike previous systems, the uplift measurement system using high speed camera is installed on the side of the rail, making maintenance convenient. On-field verification of the uplift measurement system for overhead contact wire using high speed camera was conducted by measuring uplift of the TTX followed by operation speeds at the Honam conventional line and high-speed railway line. The proposed high-speed image measurement system to evaluate dynamic uplift of overhead contact wires shows promising on-field applications for high speed trains such as KTX and TTX.

SABiT 공법적용 인쇄회로기판의 은 페이스트 범프 크기 및 제작 조건에 따른 전기 저항 특성 (Characterization of Electrical Resistance for SABiT Technology-Applied PCB : Dependence of Bump Size and Fabrication Condition)

  • 송철호;김영훈;이상민;목지수;양용석
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.298-302
    • /
    • 2010
  • We investigated the resistance change behavior of SABiT (Samsung Advanced Bump interconnection Technology) technology-applied PCB (Printed Circuit Board) with the various bump sizes and fabrication conditions. Many testing samples with different bump size, prepreg thickness, number of print on the formation of Ag paste bump, were made. The resistance of Ag paste bump itself was calculated from the Ag paste resistivity and bump size, measured by using 4-point probe method and FE-SEM (Field Emission Scanning Electron Microscope), respectively. The contact resistance between Ag paste bump and conducting Cu line were obtained by subtracting the Cu line and bump resistances from the measured total resistance. It was found that the contact resistance drastically changed with the variation of Ag paste bump size and the contact resistance had the largest influence on total resistance. We found that the bump size and contact resistance obeyed the power law relationship. The resistance of a circuit in PCB can be estimated from this kind of relationship as the bump size and fabrication technique vary.

고장 유형별 고속 인터럽터의 동작 특성 (The Operational Characteristics of High-speed Interrupter by Fault Types)

  • 정인성;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.278-283
    • /
    • 2013
  • With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.