• 제목/요약/키워드: electrical lengths

검색결과 245건 처리시간 0.025초

슬롯을 가진 삼각패치형 인공전송선로 (A Slotted Triangular-Patch Type Artificial Transmission Line)

  • 오송이;최경;황희용
    • 정보통신설비학회논문지
    • /
    • 제9권4호
    • /
    • pp.164-167
    • /
    • 2010
  • In this paper, an artificial transmission line of triangular-patch type with slots is proposed. This artificial transmission line is useful for miniaturizing the electrical lengths of conventional transmission lines. Also, this structure is easy to regulate the characteristic impedance and electrical lengths. The electrical lengths and the characteristic impedances of the proposed artificial transmission line with some parameters are researched and summarized The proposed artificial transmission line could be useful for compact designs for most of the passive microwave components. The optional-artificial transmission line is fabricated and measured at 2.45GHz.

  • PDF

삼파장 4채널 적외선식 불꽃감지기의 자가진단 성능 개선 (An Improvement on the Self Diagnostic Characteristics of the Triple Quard Channel Infrared Flame Detector)

  • 송현선
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.49-54
    • /
    • 2016
  • There is needed the quard channel triple wave lengths pyroelectric infrared flame detector to recognize the unique characteristics of fire sources in various type. This system detects the triple wave lengths of infrared flame emitting maximum radient energy and scattering frequency of flame. The quard channel infrared flame detector detects the duplicate wave lengths of maximum radient energy to enhance the accuracy of detecting fire. Especially this paper focuss on development of the self diagnosis function system including contamination, temperature and input voltage. Therefore, the prevention and early suppression of fire is available.

Preparation of Epoxy/Organoclay Nanocomposites for Electrical Insulating Material Using an Ultrasonicator

  • Park, Jae-Jun;Park, Young-Bum;Lee, Jae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권3호
    • /
    • pp.93-97
    • /
    • 2011
  • In this paper, we discuss design considerations for an n-channel metal-oxide-semiconductor field-effect transistor (MOSFET) with a lateral asymmetric channel (LAC) doping profile. We employed a 0.35 ${\mu}M$ standard complementary MOSFET process for fabrication of the devices. The gates to the LAC doping overlap lengths were 0.5, 1.0, and 1.5 ${\mu}M$. The drain current ($I_{ON}$), transconductance ($g_m$), substrate current ($I_{SUB}$), drain to source leakage current ($I_{OFF}$), and channel-hot-electron (CHE) reliability characteristics were taken into account for optimum device design. The LAC devices with shorter overlap lengths demonstrated improved $I_{ON}$ and $g_m$ characteristics. On the other hand, the LAC devices with longer overlap lengths demonstrated improved CHE degradation and $I_{OFF}$ characteristics.

균일한 임피던스 전송선로 길이 조정을 통한 비대칭 Bagley 분배기 (Unequal Bagley Divider based on Uniform Characteristic Impedance Transmission Lines with Adjustment Electrical Lengths)

  • 윤영철;홍성욱;김영
    • 한국항행학회논문지
    • /
    • 제21권3호
    • /
    • pp.287-293
    • /
    • 2017
  • 본 논문은 균일한 임피던스를 갖는 출력 포트사이 전송선로의 전기적 길이를 다르게 함으로서 비대칭 Bagley 분배기 설계에 대한 내용을 서술하였다. 이 분배기는 입력 포트와 연결된 출력 포트의 전기적 길이만을 조정하여 출력 포트에 원하는 임의의 출력 비율을 얻을 수 있고, 모든 전송선로의 특성 임피던스는 균일한 것이 특징이다. 이러한 설계 방법을 사용하면 비대칭 출력을 얻을 수 있음에도 출력포트에는 임피던스 변환기를 사용하지 않는다. 이것을 증명하기 위해서 동작주파수 2 GHz에서 1:2:1 비율의 3차와 2:3:4:3:2 비율의 5차 비대칭 Bagley 분배기를 시뮬레이션과 제작하였다. 측정 결과는 시뮬레이션과 동일함을 확인하였다.

공극 길이 차이가 양측식 리니어 펄스 모터의 특성에 미치는 영향 (Effect of Airgap Length Difference on the Characteristics of the Double-Sided Linear Pulse Motor)

  • 이동주;이은웅;김성현;손홍관;김성종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.1-8
    • /
    • 2003
  • Generally, thrust force of double-sided LPM is more powerful than that of single-sided LPM. Also, double-sided LMP can be effectively applied to the high-precision position system with its simple control scheme. However, An equality between two airgap lengths Is a necessary condition for its high performance. If a little difference between two airgaps is existed, unbalanced normal force and undesirable vibration will be generated. Additionally, even though two airgap lengths are absolutely same, undesirable vibration can be generated because the direction of instantaneous normal force on mover is changed according to excitation methods. An effect of inequality of two airgap lengths is presented in this paper. Distribution of airgap permeance vs. relative displacement is analyzed by two dimensional finite element method. Excitation From this results, current waveforms to reduce the undesirable vibration is proposed.

Odd-even Effects on the Surface Anchoring Strength and the Pretilt Angle Generation in NLC on Rubbed Polythiophene Surfaces with Alkyl Chain Lengths

  • Seo, Dae-Shik
    • 한국전기전자재료학회논문지
    • /
    • 제12권1호
    • /
    • pp.69-74
    • /
    • 1999
  • We have investigated that the high pretilt angle of the NLC, 4-n-pentyl-4-cyanobiphenyl (5CB), was observed on rubbed polythiophene (PTP) surfaces with alkyl chains with more than 10 carbon atoms; it is attributed to the surface-excluded volume effect by the alkyl chain lengths between the LCs and the PTP surfaces. Next, we investigated that the odd-even effect of the polar anchoring strength in 5CB on rubbed PTP surfaces with alkyl chain lengths has been successfully evaluated. The anchoring strength of 5CB for rubbed PTP surfaces with odd-number is weak compared with even-number up to the 6 carbon atoms in the alkyl chain; however, odd-number is strong compared with even-number above 7 carbon atoms. The weak anchoring strength of 5CB is approximately $1\times10^{-3} (J/m^2$) on rubbed PTP surface with 7 carbon atoms; it is relatively strong anchoring strength. Consequently, we conclude that the odd-even effects of the polar anchoring strength in NLCs are strongly related to the characteristics of the polymer and observed clearly for short alkyl chain lengths.

  • PDF

동작관찰 신체훈련을 병행한 기능적 전기자극치료가 뇌졸중환자의 균형과 보행에 미치는 영향 (Effects of A Combined Functional Electrical Stimulation with Action Observation Training for Balance and Gait Performance in Stroke Patients)

  • 강권영;김태윤
    • 대한물리의학회지
    • /
    • 제11권2호
    • /
    • pp.93-102
    • /
    • 2016
  • PURPOSE: The purpose of this study is to evaluate the functional effects of action observation plus functional electrical stimulation (FES) treatment on the weight distribution indexes (heel and toe; right and left), stability indexes, gait velocities, and stride lengths of stroke patients. METHODS: The subjects, who were all more than six months post stroke, were randomly divided into two groups of ten each: an experimental group and a control group. TETRAX (Tetrax Interactive Balance System) and GAITRite (GAITRite$^{TM}$ computerized gait analysis system) were measured at baseline, six weeks after treatment. Participants in both the groups received functional electrical stimulation treatment, but the experimental group was provided with additional action observation. Independent t-tests were used to compare the differences between the groups, and repeated measured two-way ANOVA was used to compare the interaction between the groups. RESULTS: The result of the interactions between the groups and the periods showed significant increases in the weight distribution indexes (heel and toe; right and left), stability indexes, gait velocities and stride lengths (p<0.05). However, a comparison between the groups showed no significance in the weight distribution indexes (heel and toe), stability indexes, and stride lengths (p>0.05). CONCLUSION: Action observation plus functional electrical stimulation treatment should be considered as a therapeutic method for physical therapy for stroke patients to improve the weight distribution indexes, stability indexes, gait velocities, and stride lengths.

게이트와 드리프트 영역 오버랩 길이에 따른 LDMOST 전력 소자의 전기적 특성 (Electrical Characteristics of LOMOST under Various Overlap Lengths between Gate and Drift Region)

  • 하종봉;나기열;조경록;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.667-674
    • /
    • 2005
  • In this paper the gate overlap length of the LDMOST is optimized for obtaining longer device lifetime. The LDMOSI device with drift region is fabricated using the $0.25\;{\mu}m$ CMOS Process. The gate overlap lengths on drift region are $0.1\;{\mu}m,\;0.4\;{\mu}m\;0.8\;{\mu}m\;and\;1.1\;{\mu}m$, respectively. The breakdown voltages, on-resistances and hot-carrier degradations of the fabricated LDMOST devices are characterized. The LDMOST device with gate overlap length of $0.4\;{\mu}m$ showed the longest on-resistance lifetime, 0.02 years and breakdown voltage of 22 V and on-resistance of $23\;m\Omega{\cdot}mm^2$.

GIS내에 함유된 자유 도전성 파티클의 거동해석 (A Numerica analysis on the lift-off motion of Free Conducting Particle in GIS)

  • 이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1925-1928
    • /
    • 1996
  • In this work, the behavior of conducting wire type particles existing inside the cylinder type coaxial electrode has been systematically investigated by charge simulation method and electrostatic force analysis from the view point of the acquired charging before being lifted off into the gap under the high ac voltage. Spheroidal charge are adopted as a image charge for the CSM analysis in order to calculate the acquired charges of the particles which are erected on the surface of the outer electrode. For this purpose, different material of the particle and their lengths and diameters have been considered in view to calculate their lift-off field, acquired charge and to understand their effect on the lift-off voltage. The results imply that the particle lengths and diameter have an different influence on the particle behavior in GIS system.

  • PDF

해저케이블 비용 모델을 이용한 HVAC 해상변전소 적정 위치 선정에 관한 연구 (A Study on Siting of HVAC Offshore Substation for Wind Power Plant using Submarine Cable Cost Model)

  • 원종남;문원식;허재선;김재철
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.451-456
    • /
    • 2013
  • Development of the technologies for offshore wind power is proceeding actively and the installation capacity is continuously increasing because of its many advantages in comparison with the land wind power. Accordingly, project for Southwestern 2.5GW offshore wind power plant is in progress in Korea. Design of electric power systems for offshore wind power plant is very important due to its high investment and operational costs. Hence, it needs to be designed in order to minimize costs. This way can be employed in determining the installation location of offshore substation for HVAC wind power plant. According to the offshore substation site, MV inter-array cable and HV export cable lengths vary and they change a total cost regarding submarine cable. This paper represents cost models with variables which are MV inter-array cable and HV export cable lengths to locate the offshore substation for HVAC wind power plant. It is classified into submarine cable installation cost, reactive power compensator installation cost, ohmic losses, and unsupplied energy cost. By minimizing a total cost, an appropriate installation site of the offshore substation is determined.