• Title/Summary/Keyword: electrical grid

Search Result 2,232, Processing Time 0.026 seconds

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Modelling and simulation of the grid-interactive inverter (계통연계형 인버터의 모델링 및 시뮬레이션)

  • An, Gyo-Sang;Im, Hui-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1345-1347
    • /
    • 2002
  • This paper describes the computer simulation results of the photovoltaic(PV) power system for the grid-connection. The major contents of this paper consist of the modeling of the PV power system for grid-connection, the analysis of the steady-state characteristics of the system, and the analysis of the transient-state characteristics of the system, respectively.

  • PDF

Inquiry of New Topology for Grid-connected Photovoltaic Inverter (PV용 계통연계형 인버터의 새로운 Topology 고찰)

  • 정영석;유권종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

A Study on the Operating Characteristics for a Grid-Connected Photovoltaic Power System (계통연계형 태양광 발전시스템의 운전특성에 관한 연구)

  • Ahn, K.S.;Hwang, I.H.;Jeong, S.J.;Lim, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2436-2438
    • /
    • 1998
  • The operating characteristics of a 3 kW grid-connected photovoltaic (PV) power system was studied by analying annual photovoltaic data. The system performance for grid connection was investigated using a DC/ AC inverter. The results of a demonstration test show that the system utilization rate is 15.6% and the system efficiency is 8.03%.

  • PDF

A Study on Discharge Characteristics of Spherically Convergent Beam Fusion Device (구형 집속 빔 핵융합 장치의 방전특성 연구)

  • Park, Jeong-Ho;Ju, Heung-Jin;Kim, Bong-Seok;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1823-1825
    • /
    • 2004
  • Spherically convergent beam fusion device accelerate ions, which are generated between outer anode and inner grid cathode, toward the spherical center. The collision of opposite direction ions give rise to fusion reactions. Spherically convergent beam fusion device is very simple and compact, therefore the device has a potential that is applied to a portable neutron source. An experimental device consist of a 20cm-diameter spherical mesh-type anode and 7cm-diameter open spherical grid cathode and was maintained at a constant pressure of about 1333 Pa by feeding argon gas.

  • PDF

Implementation of Two TMS320F28335 based BESS Controllers for Microgrid and Control Performance Test in the Hardware-in-the-Loop Simulation System (마이크로그리드용 2기의 TMS320F28335 기반 BESS 제어기 구현 및 Hardware-in-the-Loop Simulation 시스템을 이용한 제어 성능 테스트)

  • Kim, Nam-Dae;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.559-564
    • /
    • 2014
  • A microgrid as a small scale power system is operated by the grid-connected mode and islanded mode. It is anticipated that the battery energy storage system (BESS) is able to be applied to the microgrid for stable power control, such as tie-line and smoothing control in the grid-connected mode and voltage and frequency control in the islanded mode. In this paper, a digital signal processor (DSP), Two BESS controllers based on TMS320F28335 of a microgrid are implemented and are tested to show control performance in the hardware-in-the loop simulation (HILS) system.

New Three-Phase Static Transfer Switch using AC SSCB (AC SSCB를 이용한 새로운 3상 Static Transfer Switch)

  • Song, Seung-Min;Kim, Jin-Young;Kim, In-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.626-634
    • /
    • 2018
  • These days, widespread use of sensitive loads and distributed generators makes static transfer switch (STS) an essential component in power circuits to achieve a good power quality for AC Grids. In case of a short-circuit fault, previous STS cannot break the fault current. However, the proposed STS has the capability of breaking it quickly as a circuit breaker. Also if there are power quality problems such as Sag/Swell, the proposed STS can quickly transfers the load to the good quality source. Furthermore it is proved that the transfer time of the proposed STS is within one half of period of 3-phase source frequency regardless of the type of load. It is anticipated that the proposed STS may be utilized to realize many stable and reliable AC grid systems.

Enhancement of Electrical Conductivity for Ag Grid using Electrical Sintering Method (정전류 전기 소결법을 이용한 Ag 전극 배선의 전도성 향상)

  • Hwang, Jun Y.;Moon, Y.J.;Lee, S.H.;Kang, K.;Kang, H.;Cho, Y.J.;Moon, S.J.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.114.1-114.1
    • /
    • 2011
  • Electrical sintering of the front electrode for crystalline silicon solar cells was performed applying a constant DC current to the printed lines. Conducting lines were printed on glass substrate by a drop-on-demand (DOD) inkjet printer and silver nanoparticle ink. Specific resistance and microstructure of sintered silver lines and were measured with varying DC current. To find the relation between temperature increase with changing applied current and specific resistance, temperature elevation was also calculated. Sintering process finished within a few milliseconds. Increasing applied DC current, specific resistance decreased and grain size increased after sintering. Achieved minimum specific resistance is approximately 1.7 times higher than specific resistance of the bulk silver.

  • PDF

A Novel Algorithm for Reducing Restoration Time in Smart Distribution Systems Utilizing Reclosing Dead Time

  • Hussain, Akhtar;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1805-1811
    • /
    • 2014
  • After an occurrence of a fault in any distribution system, it is desired to limit the effects of the fault to smallest possible area and restore the un-faulty areas as soon as possible. Due the advancements in communication technologies, this task can be achieved in multiple efficient ways. In order to decrease the restoration time in the Smart Grid Distribution Management System (SDMS) a communication based algorithm is proposed in this paper, in which the restoration can be done during reclosing. This paper also analyzes various communication failures with power failures cases including the entire network of communication failures. Results of all these cases have been verified by doing simulations.

Stochastic Integrated Generation and Transmission Planning Incorporating Electric Vehicle Deployment

  • Moon, Guk-Hyun;Kong, Seong-Bae;Joo, Sung-Kwan;Ryu, Heon-Su;Kim, Tae-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The power industry is currently facing many challenges, due to the new environment created by the introduction of smart grid technologies. In particular, the large-scale deployment of electric vehicles (EVs) may have a significant impact on demand for electricity and, thereby, influence generation and transmission system planning. However, it is difficult to deal with uncertainties in EV charging loads using deterministic planning methods. This paper presents a two-stage stochastic decomposition method with Latin-hyper rectangle sampling (LHRS) to solve the integrated generation and transmission planning problem incorporating EV deployment. The probabilistic distribution of EV charging loads is estimated by Latin-hyper rectangle sampling (LHRS) to enhance the computational performance of the proposed method. Numerical results are presented to show the effectiveness of the proposed method.