• 제목/요약/키워드: electrical grid

검색결과 2,230건 처리시간 0.028초

경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석 (Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line)

  • 최창현;노영환
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

주파수조정용 배터리 에너지저장장치 운전방법의 개발과 적용 (Development and Application of Operation Methods of Battery Energy Storage System for Frequency Regulation)

  • 임건표;박두용
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.57-61
    • /
    • 2015
  • Current research and development efforts and other projects for energy storage systems (ESS) have recently been gaining attention. This is due to the many applications where ESS, particularly batteries, can be used. Among these are peak shaving, frequency regulation, and stabilization of renewable energy output. KEPCO has completed the construction and demonstration of a 4-MW battery energy storage system (BESS) located in Jeju City to verify its practicability in the power grid. KEPCO Research Institute has also been developing technology for the commercialization of BESS, and has been conducting a trial run of a 52-MW ESS (28MW + 24MW of Seo-Anseong and Shin-Yongin substations) constructed in 2014 for frequency regulation. This paper discusses the development of operation methods, as well as an operation user interface, for the safe operation and monitoring of BESS used for frequency regulation in a power system. Included are operation and simulation methods for various normal and transient frequency situations that can be experienced by a power system. Also discussed are the results obtained after applying these methods to the 4-MW BESS and the 52-MW ESS, both used for frequency regulation. The technology in this paper will be applied to 500MW ESS for frequency regulation of KEPCO by 2017. It is expected that this technology helps a safe and reliable operation and control of ESS for frequency regulation through its continuous upgrade.

고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구 (A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter)

  • 김영진;황평익;문승일
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

Selective Emitter 구조를 적용한 Ni/Cu Plating 전극 결정질 실리콘 태양전지 (Application of a Selective Emitter Structure for Ni/Cu Plating Metallization Crystalline Silicon Solar Cells)

  • 김민정;이재두;이수홍
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.575-579
    • /
    • 2010
  • The technologies of Ni/Cu plating contact is attributed to the reduced series resistance caused by a better contact conductivity of Ni with Si and the subsequent electroplating of Cu on Ni. The ability to pattern narrower grid lines for reduced light shading was combined with the lower resistance of a metal silicide contact and an improved conductivity of the plated deposit. This improves the FF (fill factor) as the series resistance is reduced. This is very much requried in the case of low concentrator solar cells in which the series resistance is one of the important and dominant parameter that affect the cell performance. A Selective emitter structure with highly dopeds regions underneath the metal contacts, is widely known to be one of the most promising high-efficiency solution in solar cell processing In this paper the formation of a selective emitter, and the nickel silicide seed layer at the front side metallization of silicon cells is considered. After generating the nickel seed layer the contacts were thickened by Cu LIP (light induced plating) and by the formation of a plated Ni/Cu two step metallization on front contacts. In fabricating a Ni/Cu plating metallization cell with a selective emitter structure it has been shown that the cell efficiency can be increased by at least 0.2%.

아크 발생에 따른 고장 및 화재를 보호하기 위한 직류 아크 Generator 개발 (Development of DC Arc Generator to protect against Malfunctions and Fires caused by Arcing)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.123-128
    • /
    • 2021
  • 직류 배전시스템의 보급이 증가됨에 따라 이에 따른 고장 발생 및 화재 사고도 증가하고 있고 특히 스마트 그리드의 구성 요소인 ESS 화재 사고, 직류 시스템인 태양광 발전 시스템의 화재 사고는 신재생에너지의 보급이 급격하게 증가하고 동시에 사용 연수 10년 이상의 노후 시설이 많아짐에 따라, 시스템 구성 요소 간의 전기적인 접속의 문제들로 발생하고 있다. 이로 인해 유발된 빛과 열을 방출하여 직접적인 화재의 원인이 될 수 있는 아크가 화재의 한 원인으로 지적되고 있다. 따라서 이러한 아크 결함의 문제는 기존의 과전류차단기와 누전차단기로는 아크사고를 사전에 차단할 수 없는 실정이며 대규모 유틸리티 시스템뿐만 아니라 소규모 주거 시스템에서도 인간의 안전에 중대한 위협이 될 수 있기에 아크사고에 대한 대책이 필요하다. 본 논문에서는 국제표준화에 만족하는 시험장비 개발과 아크 발생에 따른 고장 및 화재를 보호하기 위한 직류 아크 Generator를 개발 하고자 한다.

가변형 수동 고조파 필터에 의한 단상 무정전전원장치의 고조파 저감에 관한 연구 (A Study on Harmonic Reduction of Single-phase UPS with Variable Passive Harmonic Filters)

  • 김성삼;황선환
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.495-501
    • /
    • 2019
  • 본 논문에서는 정류 브리지 다이오드를 갖는 단상 무정전전원장치의 전원측 고조파 및 역률 개선을 위한 가변형 고조파 필터를 제안한다. 2레벨 이상의 전력변환방식을 적용한 무정전전원장치는 전원측 고조파 및 역률 특성이 우수한 반면, 전 브리지 방식의 무정전전원장치는 전원측에 제 3고조파, 제 5고조파, 제 7고조파 및 역률 저하를 심각하게 야기한다. 이에 따라 단상 전 브리지 동작에 의해 야기된 (2n+1)차 고조파 제거 및 역률 개선을 위한 가변형 고조파 필터를 제안하고자 한다. 제안한 가변형 고조파 필터의 성능을 평가하기 위해 다양한 시뮬레이션과 실험을 진행하여 타당성을 검증하였다.

고전압 태양광 패널용 고효율 단상 태양광 인버터 (A High-efficiency Single-phase Photovoltaic Inverter for High-voltage Photovoltaic Panels)

  • 류형민
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.584-589
    • /
    • 2022
  • 고전압 태양광 패널에서 단상 계통으로의 직류-교류 전력 변환을 위해 벅부스트 컨버터에 풀브리지 인버터를 종속적으로 연결하는 두 단계의 무변압기 인버터가 주로 사용된다. 태양광 패널의 큰 기생 커패시턴스에 기인하는 과도한 누설 전류를 피하기 위해 풀브리지 인버터는 단극성 PWM에 비해 훨씬 더 많은 전력 손실을 초래하는 양극성 PWM으로만 스위칭할 수 있다. 그런 낮은 효율을 개선하기 위해 본 논문은 벅부스트 컨버터에 회로 절연을 위한 IGBT와 다이오드를 하나씩 추가한 새로운 토폴로지를 제안한다. 제안된 회로 절연 방식은 누설 전류를 증가시키지 않으면서 풀브리지 인버터에서 단극성 PWM을 가능케 함으로써 전체 효율을 개선한다. 제안된 방법의 타당성은 컴퓨터 시뮬레이션과 전력 손실 계산을 통해 검증한다.

The influence of sea surface temperature for vertical extreme wind shear change and its relation to the atmospheric stability at coastal area

  • Geonhwa Ryu;Young-Gon Kim;Dongjin Kim;Sang-Man Kim;Min Je Kim;Wonbae Jeon;Chae-Joo Moon
    • Wind and Structures
    • /
    • 제36권3호
    • /
    • pp.201-213
    • /
    • 2023
  • In this study, the effect of sea surface temperature (SST) on the distribution of vertical wind speed in the atmospheric boundary layer of coastal areas was analyzed. In general, coastal areas are known to be more susceptible to various meteorological factors than inland areas due to interannual changes in sea surface temperature. Therefore, the purpose of this study is to analyze the relationship between sea surface temperature (ERA5) and wind resource data based on the meteorological mast of Høvsøre, the test bed area of the onshore wind farm in the coastal area of Denmark. In addition, the possibility of coastal disasters caused by abnormal vertical wind shear due to changes in sea surface temperature was also analyzed. According to the analysis of the correlation between the wind resource data at met mast and the sea surface temperature by ERA5, the wind speed from the sea and the vertical wind shear are stronger than from the inland, and are vulnerable to seasonal sea surface temperature fluctuations. In particular, the abnormal vertical wind shear, in which only the lower wind speed was strengthened and appeared in the form of a nose, mainly appeared in winter when the atmosphere was near-neutral or stable, and all occurred when the wind blows from the sea. This phenomenon usually occurred when there was a sudden change in sea surface temperature within a short period of time.

주파수조정용 ESS의 성능검증 및 경제성평가 알고리즘에 관한 연구 (A Study on The Performance Verification and Economic Evaluation of ESS for Frequency Regulation Application)

  • 이주광;최성식;강민관;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.738-744
    • /
    • 2017
  • 최근 신재생에너지의 확대 보급과 더불어 전기저장장치(ESS, Energy Storage System)가 활발하게 도입되고 있다. 하지만 현재 전기저장장치에 대한 도입효과와 경제성 및 계통에 미치는 영향에 대한 구체적인 평가방법이 없어 효과적인 도입운용이 어려운 실정이다. 특히 주파수조정용 ESS에 대한 국제적인 기술표준 및 제도가 마련되지 않아, 이의 설치에 따른 전기품질, 계통영향, 기여도 등은 물론 편익 산정에 대한 종합적인 연구가 필요한 실정이다. 따라서 본 논문에서는 주파수조정용 ESS의 성능검증 방안을 마련하기 위하여, 기존발전기의 주파수조정 성능평가 방법인 미국 PJM의 AGC(Automatic Generation Control, 발전기 자동발전제어) 성능 평가방식을 분석하여, 주파수조정용 ESS의 성능평가 알고리즘을 제안하였고, 고가발전기의 정산금과 화력발전기의 정산금을 이용하여 500MW급의 주파수조정용 ESS의 도입에 따른 편익을 산정할 수 있는 경제성 평가 알고리즘을 제시하였다. 제안한 알고리즘의 유용성을 확인하기 위하여, 실 계통 데이터를 바탕으로 시뮬레이션을 수행한 결과, 전기저장장치가 기존의 발전기에 비하여 아주 우수한 성능을 가지고 있음을 확인하였고, 500MW 도입시 연간 약 3,457~4,296억의 편익이 발생함을 확인하였다.

영상 분할을 이용한 객체 기반 집적영상 깊이 추출 (Object-Based Integral Imaging Depth Extraction Using Segmentation)

  • 강진모;정재현;이병호;박재형
    • 한국광학회지
    • /
    • 제20권2호
    • /
    • pp.94-101
    • /
    • 2009
  • 본 논문에서는 집적영상에서 깊이 추출을 할 때 영상 분할 방법을 이용하여 각각의 물체에 대해 삼각형 메쉬(mesh) 모델을 구성하는 방법을 제안하였다. 집적영상에서 렌즈 어레이와 카메라를 이용하여 실제 물체를 픽업하면 요소영상(Elemental image) 집합을 얻을 수 있다. 요소영상 집합은 3차원 물체의 정보를 가지고 있으므로 대응점 분석을 통해 깊이 추출을 할 수 있다. 우선, 각 요소영상 중심점의 대응점 분석을 통해 시차를 구하고 이를 이용하여 깊이를 구한다. 요소영상의 중심점에 해당하는 물체의 X, Y 공간좌표는 각 점들이 사각형 격자 형태를 이룬다. 이 격자 형태의 점들 중에서 가까운 점 3개를 연결하여 삼각형 메쉬를 만들면 물체의 삼각형 메쉬 모델을 구할 수 있다. 이 때 각 물체에 대해 삼각형 메쉬 모델을 구하기 위해서 요소영상의 중심점들로 구성된 가운데 방향별 영상을 영상 분할하고 각각의 분할된 영역에 대해서만 삼각형 메쉬 모델을 구성하였다. 영상 분할 방법은 normalized cut 방법을 이용하였다. 제안된 방법의 검증을 위해 실제 물체를 픽업하고 각 물체의 삼각형 메쉬 모델을 구성하였다.